FDA Adverse Event Injury Summary report: Y

UNK HEAD

MDR report key: 23232528 · Received October 7, 2025

Report

Report Number
0001822565-2025-03669
Event Type
Injury
Date Received
October 7, 2025
Date of Event
January 24, 2025
Report Date
April 28, 2026
Manufacturer
ZIMMER BIOMET, INC.
Product Code
LPH
PMA / PMN Number
NA
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
SW
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

(B)(4). B3: PUBLICATION DATE. D10: UNK LINER UNKNOWN. G2: FOREIGN: SWEDEN. SUGGESTED COMPONENT CODE- MECHANICAL (G04): HEAD. CUSTOMER HAS INDICATED THAT THE PRODUCT WILL NOT BE RETURNED TO ZIMMER BIOMET FOR INVESTIGATION. THE INVESTIGATION IS IN PROCESS. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED. REFERENCE: MICHAEL AXENHUS, GHAZI CHAMMOUT, PAULA KELLY-PETTERSSON, SEBASTIAN MUKKA, MARTIN MAGNÉLI, OLOF SKÖLDENBERG LONG-TERM OUTCOMES OF CEMENTED COMPARED TO UNCEMENTED FEMORAL STEMS IN TOTAL HIP ARTHROPLASTY FOR DISPLACED FEMORAL NECK FRACTURES IN ELDERLY PATIENTS EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY (2025) 51:73HTTPS://DOI.ORG/10.1007/S00068-024-02735-0.

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. THE FOLLOWING SECTIONS WERE UPDATED: B4, B5, G3, G6, H2, H3, H6, H11. THE REPORTED EVENT COULD NOT BE CONFIRMED DUE TO LACK OF PRODUCT/EVENT INFORMATION. NO PRODUCT WAS RETURNED OR PICTURES PROVIDED; VISUAL AND DIMENSIONAL EVALUATIONS COULD NOT BE PERFORMED. DEVICE HISTORY RECORD REVIEW CANNOT BE PERFORMED WITHOUT PRODUCT IDENTIFICATION. A DEFINITIVE ROOT CAUSE CANNOT BE DETERMINED. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL REPORT WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.

Description of Event or Problem · 0

IT WAS REPORTED IN A JOURNAL ARTICLE THAT WAS OBTAINED PROVIDED THAT THE PURPOSE OF THE STUDY WAS TO ASSESS LONG-TERM OUTCOME OF CEMENTED AND UNCEMENTED STEM RESULTS. THE STUDY REVIEWED 69 PATIENTS WITH DISPLACED FEMORAL NECK FRACTURES. ALL SURGERIES WERE PERFORMED USING DIRECT LATERAL APPROACH WITH THE PATIENT IN THE LATERAL DECUBI¬TUS POSITION, PATIENTS WERE SPLIT INTO 2 GROUPS; CEMENTED GROUP RECEIVED THE MODULAR CPT (ZIMMER, WARSAW, INDIANA, USA) AND THE UNCEMENTED GROUP RECEIVED THE BI-METRIC STEM (BIOMET, WARSAW, INDIANA, USA). THE STUDY POPULATION HAD A MEAN AGE OF 73 YEARS AT TIME OF SURGERY; (NUMBER OF 22 MALES/47 FEMALES). FOLLOW-UP WAS CONDUCTED AT 3, 12, 24 MONTHS, AND AT 4 AND 10 YEARS AFTER THE SURGERY. COMPLAINT 4: THE STUDY REPORTED ONE PATIENT WITHIN THE UNCEMENTED GROUP WITH DISLOCATIONS RESULTING IN STEM REVISION.

Description of Event or Problem · 0

NO ADDITIONAL EVENT INFORMATION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
7014 UNK HEAD PROSTHESIS, HIPS LPH ZIMMER BIOMET, INC. N/A UNK

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Hospitalization| R SEE H11 NARRATIVE.