PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2025-10754
- Event Type
- Injury
- Date Received
- September 19, 2025
- Date of Event
- March 1, 2025
- Report Date
- September 19, 2025
- Manufacturer
- ETHICON INC.
- Product Code
- GAW
- PMA / PMN Number
- K133356
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS
- Reporter Occupation
- OTHER
Narratives
PRODUCT COMPLAINT #: (B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE SURGEON BELIEVE THAT ANY OF THE ETHICON PRODUCTS INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? WHICH SPECIFIC ETHICON PRODUCTS HAVE BEEN USED DURING THE PROCEDURES (PRODUCT CODE, LOT NUMBER)? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH ANY OF THE ETHICON PRODUCTS USED IN THIS PROCEDURE? IF SO, PLEASE PROVIDE DETAILS. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. PATIENT DEMOGRAPHICS? THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. H6 COMPONENT CODE: G07002 ¿ DEVICE NOT RETURNED THE SINGLE COMPLAINT WAS REPORTED WITH MULTIPLE EVENTS. THERE ARE NO ADDITIONAL DETAILS REGARDING THE ADDITIONAL EVENTS. D4: UDI: AS THE CATALOG/MODEL NUMBER WAS NOT PROVIDED, THE (01)GTIN IS NOT AVAILABLE. CITATION: TRANSPLANTATION. 2025 MAR 1;109(3):E166-E174. HTTPS://DOI.ORG/10.1097/TP.0000000000005245 EPUB 2024 OCT 23. PMID: 39439020.
TITLE: PROPENSITY SCORE-MATCHED DONOR AND RECIPIENT OUTCOMES: ROBOTIC VERSUS LAPAROSCOPIC DONOR RIGHT HEPATECTOMY. THE AIM OF THIS RETROSPECTIVE STUDY WAS TO COMPARE SHORT-TERM AND TOTAL FOLLOW-UP OUTCOMES BETWEEN DONORS AND RECIPIENTS OF LAPAROSCOPIC DONOR RIGHT HEPATECTOMY (LDRH) AND ROBOTIC DONOR RIGHT HEPATECTOMY (RDRH) AT A SINGLE INSTITUTION. BETWEEN MARCH 2016 AND JUNE 2023, A TOTAL OF 235 DONORS WHO UNDERWENT RIGHT HEPATECTOMY FOR LIVING DONOR LIVER TRANSPLANTATION (LDLT) WERE INCLUDED. AMONG THESE PATIENTS, 117 PATIENTS (55 MALE AND 62 FEMALE; MEAN AGE OF 30.5 ± 9.4 YEARS) UNDERWENT RDRH STARTING AND 118 PATIENTS (58 MALE AND 60 FEMALE; MEAN AGE OF 32.2 ± 10.9 YEARS) UNDERWENT LDRH. SPECIFICALLY, RDRH USES A HARMONIC SCALPEL AND MARYLAND BIPOLAR FORCEPS, WHEREAS LDRH USES A CAVITRON ULTRASONIC SURGICAL ASPIRATOR AS THE MAIN DEVICE. DURING BD DIVISION, THE RDRH USES A ROBOTIC FIREFLY SYSTEM WITH 3D VISION; HOWEVER, LDRH SWITCHES TO A 2-DIMENSIONAL (2D) NEAR-INFRARED CAMERA FROM A 3D FLEXIBLE CAMERA TO CONFIRM THE BIFURCATION AND STRUCTURE OF THE BD USING INDOCYANINE GREEN (ICG). THE BD DIVISION FOLLOWS THE PREVIOUSLY REPORTED TECHNIQUE KNOWN AS ¿CLIP AND CUT¿ (FIGURE 1A AND B). IN MOST CASES, THE RIGHT HEPATIC DUCT WITH THE HILAR PLATE WAS ISOLATED, AND HEM-O-LOK (GRENA, LONDON, UNITED KINGDOM) WAS APPLIED. THE BD WAS THEN DIVIDED WITH A 1MM SAFETY MARGIN FROM THE SITE WHERE THE HEM-O-LOK WAS APPLIED. THE STUMP OF THE RIGHT HEPATIC DUCT, WHERE THE HEM-O-LOK WAS APPLIED, WAS REINFORCED USING A 6-0 MONOFILAMENT SUTURE (PROLENE POLYPROPYLENE SUTURE; ETHICON INC., JOHNSON & JOHNSON MEDICAL SPA, SOMERVILLE, NJ). RECENTLY, THE BD DIVISION PROCEDURE WAS MODIFIED, REFERRED TO AS ¿CUT AND SUTURE¿ (FIGURE 1C¿F) FOR SELECTED CASES WITH A SHORT RIGHT HEPATIC DUCT. IN THESE INSTANCES, THE BD WAS FIRST ISOLATED AND DIVIDED WITH SCISSORS, AND THEN THE OPENING WAS CLOSED WITH CONTINUOUS SUTURING USING A 6-0 NONABSORBABLE SUTURE. REPORTED COMPLICATIONS OF DONORS INCLUDE GRADE IIIA (N=6), GRADE IIIB (N=3), AND GRADE IV (N=1). IN CONCLUSION, RDRH DEMONSTRATED COMPARABLE POSTOPERATIVE COMPLICATIONS TO LDRH IN DONORS BUT SHOWED FEWER RECIPIENT BILIARY COMPLICATIONS. THIS COULD BE ATTRIBUTED TO THE PRECISION OF ROBOTIC DISSECTION AND BD DIVISION, RESULTING IN FEWER MULTIPLE BD OPENINGS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1760072 | PROLENE POLYPROPYLENE SUTURE UNKNOWN PRODUCT | SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE | GAW | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Required Intervention |