FDA Adverse Event Malfunction Summary report: N

INSYTE

MDR report key: 23078566 · Received September 17, 2025

Report

Report Number
9610048-2025-00124
Event Type
Malfunction
Date Received
September 17, 2025
Date of Event
September 8, 2025
Report Date
October 15, 2025
Manufacturer
BECTON DICKINSON INDUSTRIAS CIRURGICAS, LTDA.
Product Code
FOZ
UDI-DI
00382903883110
PMA / PMN Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
PE
Reporter Occupation
NURSE
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

B3. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. H.3. A FOLLOW UP MDR WILL BE SUBMITTED IF ADDITIONAL INFORMATION, A DEVICE EVALUATION, OR A DEVICE HISTORY REVIEW IS COMPLETED.

Additional Manufacturer Narrative · 0

A DEVICE HISTORY RECORD REVIEW WAS COMPLETED FOR PROVIDED MATERIAL NUMBER 38831114 AND LOT NUMBER 4183704. THE REVIEW DID NOT REVEAL ANY DETECTED ABNORMALITIES DURING THE PRODUCTION PROCESS THAT COULD HAVE CONTRIBUTED TO THE REPORTED DEFECT AND ALL QUALITY TESTS WERE FOUND TO BE WITHIN SPECIFICATION. AS SAMPLES WERE UNAVAILABLE FOR THIS EVENT, A THOROUGH SAMPLE ANALYSIS COULD NOT BE COMPLETED. ALTHOUGH AN EXACT CAUSE COULD NOT BE DETERMINED FOR THIS COMPLAINT IT IS POSSIBLE THAT THE REPORTED DEFECT RESULTED FROM PRODUCT USE. DURING THE 360-DEGREE ROTATION PERFORMED DURING PUNCTURE, THE CATHETER MAY HAVE BEEN PUSHED FORWARD, RE-CANNULATING THE DEVICE AND CAUSING THE CATHETER TO BECOME TRANSFIXED. IT IS ALSO POSSIBLE THAT DURING PRODUCT ASSEMBLY, A FAILURE IN THE VISION SYSTEM ALLOWED A TRANSFIXED CATHETER TO PASS THROUGH TO THE CUSTOMER. HOWEVER, IF THE CATHETER WAS TRANSFIXED PRIOR TO PUNCTURE, USE OF THE PRODUCT WOULD NOT BE POSSIBLE. IMPROVEMENT ACTIONS OF THE ISSUE OF NEEDLE THROUGH CATHETER WERE IMPLEMENTED THROUGH A PREVIOUS CORRECTIVE AND PREVENTIVE ACTION PLAN FROM SEPTEMBER 2024. THE LOT INVOLVED IN THIS REPORT WAS MANUFACTURED PRIOR TO THE IMPLEMENTATION OF THESE ACTIONS. OUR QUALITY TEAM WILL CONTINUE TO CLOSELY MONITOR THE MANUFACTURING PROCESS FOR SIGNS OF THIS POTENTIAL DEFECT AND ANY EMERGING TRENDS.

Description of Event or Problem · 0

IT WAS REPORTED THAT CATHETER N° 24 WITH BLUNT BICEL, PLASTIC WITH HOLES WHERE BLOOD COMES OUT AND DRIPS, DIFFICULT TO ENTER MAKING A SLIGHT EFFORT TO PUNCTURE THE VEIN. WHEN IT IS IN THE VEIN, WHEN THE NEEDLE IS TAKEN OUT, THE CATHETER IS BLUNT AND THE RUPTURE IS FELT, CAUSING PAIN IN THE PATIENT AND REPEATED VENIPUNCTURES THAT CAUSE RISK OF INFECTION.

Description of Event or Problem · 0

NO ADDITIONAL INFORMATION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1635721 INSYTE PERIPHERAL IV CATHETERS FOZ BECTON DICKINSON INDUSTRIAS CIRURGICAS, LTDA. 4183704 00382903883110

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown