BD SYRINGE 5ML S/T BNS
Report
- Report Number
- 1213809-2025-00581
- Event Type
- Malfunction
- Date Received
- September 5, 2025
- Date of Event
- May 20, 2025
- Report Date
- August 22, 2025
- Manufacturer
- BECTON DICKINSON MEDICAL SYSTEMS
- Product Code
- FMF
- UDI-DI
- 50382903010283
- PMA / PMN Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IL, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
E.1. ADDRESS WAS NOT LOCATED AND IL WAS USED. FIFTY SAMPLES OF 5 ML LUER-SLIP SYRINGES WERE RECEIVED AND EVALUATED. ALL SAMPLES WERE LOOSE WITHIN TWO SEPARATE BAGS OF TWENTY-FIVE, EACH LABELED WITH A DIFFERENT BATCH. BATCH 5078135 CONTAINED EIGHTEEN DEFECT-FREE SAMPLES AND SEVEN WITH MAJOR PLUNGER ROD DAMAGE. BATCH 5062523 HAD FIFTEEN DEFECT-FREE SAMPLES, TEN WITH THE STOPPER JAMMED BETWEEN THE BARREL AND PLUNGER ROD, AND ONE WITH A BROKEN BARREL TIP. DROPLETS WERE OBSERVED ON THE ROOF OF MOST BARRELS, WITH NO STRINGING OR POOLING. FOURIER TRANSFORM INFRARED SPECTROSCOPY (FTIR) ANALYSIS ON ONE SAMPLE FROM EACH BATCH CONFIRMED THE DROPLETS TO BE SILICONE USED IN THE MANUFACTURING PROCESS. THE OBSERVED CONDITIONS ARE NON-CONFORMING PER PRODUCT SPECIFICATIONS. THE POTENTIAL ROOT CAUSE FOR THE PLUNGER ROD DAMAGE AND STOPPER JAMMED DEFECTS IS ASSOCIATED WITH THE ASSEMBLY PROCESS. SILICONE IS APPLIED AS A SPRAY OF PARTICLES TO THE INSIDE OF THE BARREL. IT IS UNCLEAR WHAT TYPE OF STORAGE AND HANDLING CONDITIONS THE PRODUCT WAS SUBJECTED TO AFTER LEAVING THE MANUFACTURING PLANT. SILICONE IS AN INERT, NON-TOXIC MEDICAL SUBSTANCE USED AS A LUBRICANT FOR DISPOSABLE HYPODERMIC PRODUCTS. IT IS AN INTEGRAL PART OF THE SYRINGE, ENABLING IT TO PERFORM AS REQUIRED IN VARIOUS CLINICAL APPLICATIONS AND DOES NOT PRESENT A SAFETY OR EFFICACY ISSUE NOR DOES IT IMPACT PRODUCT FUNCTION. SILICONE HAS BEEN IN USE IN THIS APPLICATION FOR OVER 25 YEARS, WITH ESTIMATED DISTRIBUTION WELL IN EXCESS OF 30 BILLION UNITS. NO REPORTS ARE KNOWN OF ADVERSE CLINICAL EFFECTS ASSOCIATED WITH THESE PRODUCTS AND UNINTENTIONAL DELIVERY OF SILICONE FLUID LUBRICANT. PLEASE REFER TO THE ATTACHED SILICONE QUANTITY GUIDELINE FOR REFERENCE. FURTHERMORE, A DEVICE HISTORY RECORD REVIEW WAS COMPLETED FOR PROVIDED LOT NUMBER 5078135 AND 5062523. A REVIEW SHOWED NO REJECTED INSPECTIONS OR QUALITY ISSUES DURING THE PRODUCTION THAT COULD HAVE CONTRIBUTED TO THE REPORTED DEFECT. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS.
IT WAS REPORTED THAT THE BD SYRINGE 5ML S/T BNS HAD VISIBLE SILICONE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL #301028. LOT #5078135, 5062523. IT WAS REPORTED BY CUSTOMER THAT FM NONCONFORMANCES WITH *BD301028*SYRINGE:5ML-SLIP-TIP. VERBATIM: HELLO¿. (B)(6), PRODUCTION JUST NOTIFIED ME OF MORE FM NONCONFORMANCES WITH *BD301028*SYRINGE:5ML-SLIP-TIP** THE FOLLOWING LOT NUMBERS: XXXX MANUFACTURING IS SENDING BACK TO XXXX IQC. THERE ARE 4 DIFFERENT LOTS THIS TIME. 2541110.1 QTY (B)(4). 2536995.1 QTY (B)(4). 2544338.1 QTY (B)(4). 2550363.1 QTY (B)(4). XXXXXX COMPLAINTS-HAVE YOU IDENTIFIED THE ROOT CAUSE TO THIS ISSUE? COMPLAINT # (B)(4). ADDITIONAL INFORMATION PROVIDED: 1. AS YOU MENTIONED, ALL ITEMS ARE AFFECTED BY FOREIGN MATTER. COULD YOU PLEASE SPECIFY WHERE THE FOREIGN MATTER WAS FOUND? WAS IT WITHIN THE FLUID PATHWAY? YES, THE FOREIGN MATTER IS LOCATED WITHIN THE FLUID PATHWAY, ALONG WITH OTHER AREAS OF THE UNITS. 2. THE TRACKING INFORMATION FOR THE PROVIDED SHIPPING LABEL STILL SHOWS THE INITIAL LOCATION. COULD YOU PLEASE LET US KNOW WHEN THE SAMPLE IS EXPECTED TO BE SHIPPED? THE SAMPLES WILL BE SHIPPED OUT TOMORROW MORNING, 12JUN2025.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 265689 | BD SYRINGE 5ML S/T BNS | PISTON SYRINGE | FMF | BECTON DICKINSON MEDICAL SYSTEMS | 5062523 | 50382903010283 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |