FDA Adverse Event Malfunction Summary report: N

BD PHOENIX PANEL NMIC-306

MDR report key: 22953166 · Received September 3, 2025

Report

Report Number
1119779-2025-04890
Event Type
Malfunction
Date Received
September 3, 2025
Date of Event
June 2, 2024
Report Date
July 10, 2025
Manufacturer
BECTON DICKINSON & CO. (SPARKS)
Product Code
LON
UDI-DI
00382904492922
PMA / PMN Number
SEE H.11
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NJ, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

G5. MULTIPLE PMA / 510(K)#: K020322, K022129, K023444, K023634, K023858, K024153, K031530, K031699, K031912, K032299, K032567, K032655, K033362, K033560, K041384, K042932, K052269, K060214, K060217, K060257, K060444, K060447, K061327, K061355, K062207, K062944, K063301, K063486, K063573, K063811, K063824, K071623, K132674, K132909, K151320, K181665, K173252, K190905, K163637, K173523, K033458, AND K123266. INVESTIGATION SUMMARY: THIS COMPLAINT IS FOR HIGH MIC MEROPENEM (MEM) AND ERTAPENEM (ETP) WITH CITROBACTER WHEN USING PHOENIX PANEL NMIC-306 (CATALOG NUMBER 449292) BATCH NUMBER 4100303. THE CUSTOMER DID NOT PROVIDE ISOLATES OR PANEL RETURNS BUT PROVIDED PHOENIX GENERATED LAB REPORTS FOR THE INVESTIGATION. THE LAB REPORTS SHOW HIGH MIC MEM AND ETP WITH CITROBACTER WHEN USING THE COMPLAINT BATCH. TO INVESTIGATE, THREE RETENTION PANELS FROM THE COMPLAINT BATCH WERE INOCULATED WITH IN HOUSE ISOLATE CITROBACTER FREUNDII ENF 10852 THEN PLACED IN A PHOENIX M50 FOR MEM AND ETP MIC RESULTS. IN ADDITION, TWO CONTROL PANELS FROM THE SAME MATERIAL BUT DIFFERENT BATCH WERE INOCULATED WITH IN HOUSE ISOLATE CITROBACTER FREUNDII ENF 10852 THEN PLACED IN A PHOENIX M50 FOR MEM AND ETP MIC RESULTS. RESULTS OF THE INVESTIGATION RETURNED ALL PANELS WITH THE EXPECTED MIC FOR MEM AND ETP. THIS COMPLAINT IS NOT CONFIRMED. THE BATCH HISTORY RECORD WAS SATISFACTORY AND NO QUALITY NOTIFICATIONS WERE GENERATED DURING MANUFACTURING AND INSPECTION. COMPLAINT TRENDING WAS PERFORMED AND NO TRENDS WERE IDENTIFIED ASSOCIATED WITH THIS DEFECT. BD WILL CONTINUE TO MONITOR FOR TRENDS AND TAKE ACTION AS NECESSARY. PLEASE CONTINUE TO COMMUNICATE ANY ADDITIONAL CONCERNS. THIS MDR IS BEING SUBMITTED AS PART OF A RETROSPECTIVE REVIEW OF RECORDS DATING APRIL 2023-2025, UNDER CAPA 11910483.

Description of Event or Problem · 0

IT WAS REPORTED WHILE USING BD PHOENIX PANEL NMIC-306, A SAMPLE GAVE DIFFERENT RESULTS WHEN RETESTED. THERE WAS NO REPORT OF PATIENT IMPACT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1474301 BD PHOENIX PANEL NMIC-306 SYSTEM, TEST, AUTOMATED ANTIMICROBIAL SUSCEPTIBILITY LON BECTON DICKINSON & CO. (SPARKS) 4100303 00382904492922

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown