HAMILTON-G5
Report
- Report Number
- 3001421318-2025-00777
- Event Type
- Malfunction
- Date Received
- August 29, 2025
- Date of Event
- May 8, 2025
- Report Date
- October 8, 2025
- Manufacturer
- HAMILTON MEDICAL AG
- Product Code
- CBK
- UDI-DI
- 07630002800013
- PMA / PMN Number
- K193228
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER
- Health Professional
- N
Narratives
HAMILTON MEDICAL AG COMPLAINT NUMBER: (B)(4). INVESTIGATION ONGOING.
HAMILTON MEDICAL AG COMPLAINT NUMBER: (B)(4). FOLLOW-UP 1: DEVICE EVALUATION. HAMILTON MEDICAL AG RECEIVED THE LOGFILES OF THE DEVICE FOR ANALYSIS. ALL IMPORTANT ACTIONS SUCH AS OPERATOR SETTINGS, ACTIONS AND ALARMS, ETC. ARE DOCUMENTED IN THE LOGFILES. THE LOGFILES ANALYSIS SHOW THAT THE DEVICE ALARMED WITH TF5506, 5505 AND 5502 ON MAY 8TH, 2025. ON (B)(6) 2025 10:17:29 TF : 5506 TECH FAULT 5506, ON (B)(6) 2025 10:17:26 LOW TIDAL VOLUME ALARMS 4005, ON (B)(6) 2025, 10:17:26 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6) 2025, 10:17:26 TF : 5502 TECH FAULT 5502, ON (B)(6)2025, 10:17:24 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:17:24 TF : 5505 TECH FAULT 5505, ON (B)(6)2025, 10:17:18 OXYGEN SUPPLY FAILED SUPPLY 5016, ON (B)(6)2025, 10:17:17 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:17:17 TF : 5506 TECH FAULT 5506, ON (B)(6)2025, 10:17:16 LOW MINUTE VOLUME ALARMS 5006, ON (B)(6)2025, 10:17:14 LOW TIDAL VOLUME ALARMS 4005, ON (B)(6)2025, 10:17:14 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:17:14 TF : 5502 TECH FAULT 5502, ON (B)(6)2025, 10:17:12 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:17:12 TF : 5505 TECH FAULT 5505, ON (B)(6)2025 ,10:17:00 OXYGEN SUPPLY FAILED SUPPLY 5016, ON (B)(6)2025, 10:16:59 LOW MINUTE VOLUME ALARMS 5006, ON (B)(6)2025, 10:16:59 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:16:59 TF : 5506 TECH FAULT 5506, ON (B)(6)2025 , 10:16:56 LOW TIDAL VOLUME ALARMS 4005, ON (B)(6)2025, 10:16:56 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:16:56 TF : 5502 TECH FAULT 5502, ON (B)(6)2025, 10:16:54 AUDIO PAUSED OFF SPECIAL 517, ON (B)(6)2025, 10:16:54 TF : 5505 TECH FAULT 5505, ON (B)(6)2025, 10:16:43 OXYGEN 100 % SETTING 302. ACCORDING TO THE SERVICE MANAL FOR HAMILTON-G5 THE RESPECTIVE TF'S INDICATE THE FOLLOWING: TF5502: POWER SUPPLY SIGNAL OUT OF RANGE (-15/ +15V ± 10%) FOR 1 SECOND. TF5505: TF 5505: TANK PRESSURE ABOVE 550 MBAR FOR 50 MS, INDICATING THAT A MIXER VALVE IS LEAKING OR THE TANK OVERPRESSURE VALVE IS DEFECTIVE. TF 5506: ERROR P TANK SIGNAL ON THE SERVO BOARD REMAINS ACTIVE FOR 5 SECONDS AND THE TANK PRESSURE IS TOO HIGH, INDICATING THAT A MIXER VALVE IS LEAKING. UPON INSPECTION, IT WAS DETERMINED THAT THE ROOT CAUSE WAS A STUCK TANK OVER PRESSURE RELIEF VALVE SPRING . THE TANK OVERPRESSURE RELIEF VALVE WAS RECONNECTED, AND THE ISSUE WAS RESOLVED.
HAMILTON MEDICAL AG RECEIVED THE FOLLOWING EVENT DESCRIPTION: THE DEVICE ALARMED WITH TF- 5505, 5502, 5506. NO HARM TO THE PATIENT WAS REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2222423 | HAMILTON-G5 | HAMILTON-G5 | CBK | HAMILTON MEDICAL AG | 159001 | 07630002800013 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |