FDA Adverse Event Malfunction Summary report: N

TECNIS SIMPLICITY

MDR report key: 22913659 · Received August 28, 2025

Report

Report Number
3012236936-2025-000219
Event Type
Malfunction
Date Received
August 28, 2025
Date of Event
August 4, 2025
Report Date
October 13, 2025
Manufacturer
AMO PUERTO RICO MFG. INC.
Product Code
HQL
UDI-DI
05050474731592
PMA / PMN Number
P980040
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MN, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL INFORMATION: SECTION D-9: DEVICE AVAILABLE FOR EVALUATION: YES. SECTION D-9: DEVICE DATE RETURNED TO MANUFACTURER: SEPT 10, 2025. SECTION H-3: DEVICE EVALUATED BY MANUFACTURER: YES. DEVICE EVALUATION: VISUAL INSPECTION OF THE COMPLAINT DEVICE REVEAL THAT THE LENS WAS RECEIVED CUT IN HALF AND COATED IN TAPE RESIDUE. THE LENS HALVES WERE CLEANED REVEALING THAT THE LENS WAS DAMAGED, HAD HAPTIC DAMAGE, AND HAD ONE HAPTIC DETACHED. THE COMPLAINT ISSUE WAS IDENTIFIED DURING PRODUCT EVALUATION; HOWEVER, BASED ON THE COMPLAINT INVESTIGATION RESULTS THE COMPLAINT ISSUE COULD NOT BE CONFIRMED TO BE RELATED TO THE MANUFACTURING OR DESIGN PROCESS. THEREFORE, THERE IS NO INDICATION OF A PRODUCT DEFICIENCY OR PRODUCT MALFUNCTION. THE OTHER OBSERVED ISSUES DURING THE PRODUCT EVALUATION COULD NOT BE CONFIRMED TO BE RELATED TO A MANUFACTURING OR DESIGN ISSUE. BASED ON THE COMPLAINT INVESTIGATION RESULTS, THE PRODUCT WAS RELEASED WITHIN SPECIFICATIONS. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.

Additional Manufacturer Narrative · 0

SECTION A2, A3,A4 AND A5: UNKNOWN/ NOT PROVIDED. SECTION D6A: IF IMPLANTED, GIVE DATE: UNKNOWN/ NOT PROVIDED. SECTION D6B: IF EXPLANTED, GIVE DATE: UNKNOWN/ NOT PROVIDED. SECTION H3: OTHER 81: THE DEVICE WAS NOT RETURNED FOR EVALUATION. THEREFORE, A FAILURE ANALYSIS OF THE COMPLAINT DEVICE CANNOT BE COMPLETED. A REVIEW OF THE DEVICE HISTORY RECORD, COMPLAINT TRENDING, AND RISK DOCUMENTATION FOR THIS DEVICE WILL BE PERFORMED. UPON COMPLETION OF THE REVIEW, IF THERE IS ANY FURTHER RELEVANT INFORMATION A SUPPLEMENTAL MEDWATCH WILL BE FILED. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE IMPLANTED LENS WAS CRACKED AND HAD PATIENT CONTACT. NO FURTHER INFORMATION IS AVAILABLE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2520253 TECNIS SIMPLICITY INTRAOCULAR LENS HQL AMO PUERTO RICO MFG. INC. DIB00 05050474731592

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown