FDA Adverse Event Malfunction Summary report: N

GENTEK HEXALOBULAR SCREWDRIVER, 28 MM

MDR report key: 22791377 · Received August 13, 2025

Report

Report Number
3008932779-2025-00027
Event Type
Malfunction
Date Received
August 13, 2025
Report Date
September 2, 2025
Manufacturer
ZFX GMBH
Product Code
NDP
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AU
Reporter Occupation
DENTIST
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

ZIMVIE COMPLAINT NUMBER (B)(4). B3: DATE OF EVENT UNKNOWN / NOT PROVIDED. D4: ADDITIONAL DEVICE INFORMATION UNKNOWN / NOT PROVIDED. E1: REPORTER EMAIL ADDRESS UNKNOWN / NOT PROVIDED. H4: DEVICE MANUFACTURER DATE UNKNOWN / NOT PROVIDED.

Additional Manufacturer Narrative · 0

ZIMVIE COMPLAINT NUMBER (B)(4). THE FOLLOWING FIELDS HAVE BEEN UPDATED: B4: DATE OF THIS REPORT. B5: DESCRIBE EVENT OR PROBLEM. G3: DATE RECEIVED BY MANUFACTURER. G6: TYPE OF REPORT. H1: TYPE OF REPORTABLE EVENT. H2: FOLLOW UP TYPE. H3: DEVICE EVALUATED BY MANUFACTURER. H6: ADVERSE EVENT PROBLEM. H10: ADDITIONAL NARRATIVE. ZIMVIE RECEIVED ONE (1) ITEM ZFX02HLD28, NO LOT NUMBER COMMUNICATED. VISUAL EVALUATION WAS PERFORMED. THE SCREWDRIVER WAS DETECTED WITH THE BROKEN TIP. THE SCREWDRIVER TIP HAS BEEN STRENGTHENED BY OFTEN USE AND/OR HIGH TORQUE VALUES, THE BREAKAGE AREA SHOWS SIGNS OF TORSION AND A SUDDEN BREAKAGE TYPE. BASED ON THE INVESTIGATION AND RISK MANAGEMENT FILE RMF, THE MOST LIKELY ROOT CAUSE DETERMINED FROM THE INVESTIGATION WAS SUDDEN BREAKAGE AFTER OVER-TORQUING OF THE SCREWDRIVER. THEREFORE, BASED ON THE AVAILABLE INFORMATION, A DEVICE MALFUNCTION WAS NOT ESTABLISHED. THE REPORTED EVENT WAS CONFIRMED. NO FURTHER INVESTIGATION OR IMMEDIATE CAPA / HHE/D ESCALATION IS REQUIRED, AS THE COMPLAINT INVESTIGATION DID NOT CONFIRM THE PRODUCTS WERE NONCONFORMING AT THE TIME OF DISTRIBUTION, AND NO NEW FAILURE MODE, HARM, OR HAZARDOUS SITUATION WAS IDENTIFIED THROUGH THE INVESTIGATION PERFORMED. AT THIS TIME, THE COMPLAINT INVESTIGATION HAS BEEN COMPLETED AND THE RECORD WILL BE CLOSED. IF ADDITIONAL INFORMATION IS RECEIVED, THE RECORD WILL BE RE-OPENED FOR FURTHER EVALUATION.

Description of Event or Problem · 0

IT WAS REPORTED A SCREWDRIVER TIP FRACTURE. NO IMPACT ON THE PATIENT WAS REPORTED. THE PROCESS WAS COMPLETED WITH ANOTHER INSTRUMENT.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
78916 GENTEK HEXALOBULAR SCREWDRIVER, 28 MM DENTAL DRIVER NDP ZFX GMBH

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown