O-ARM IMAGING SYSTEM
Report
- Report Number
- 3004785967-2025-00544
- Event Type
- Injury
- Date Received
- August 8, 2025
- Date of Event
- January 22, 2024
- Report Date
- August 8, 2025
- Manufacturer
- MEDTRONIC NAVIGATION, INC. (BOXBOROUGH)
- Product Code
- OXO
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
E0139: NEUROLOGICAL DEFICIT E1309: URINARY RETENTION E2302: MOTOR DEFICIT/WEAKNESS G2: THIS EVENT OCCURRED IN FRANCE, SEE SECTION E. H3, H6: NO PRODUCTS WERE RETURNED TO MEDTRONIC FOR ANALYSIS. CODES B17, C20, AND D15 ARE APPLICABLE. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
CITATION: EUROPEAN SPINE JOURNAL (2024) 33:1930¿1940 HTTPS://DOI.ORG/10.1007/S00586-023-08121-5 SUMMARY: PURPOSE: TO DESCRIBE THE TECHNIQUE AND REVIEW THE ONCOLOGICAL AND SURGICAL RESULTS OF THE EN BLOC RESECTION ASSISTED BY RETROPERITONEAL LAPAROSCOPY IN ASINGLE PRONE POSITION FOR TUMORS IN THE THORACOLUMBAR REGION. METHODS: MONOCENTRIC RETROSPECTIVE CASE STUDY. PROCEDURE WAS PERFORMED IN A SINGLE PRONE POSITION BY A DUAL TEAM OF SPINE AND THORACOVASCULAR SURGEONS. AN ENDOSCOPIC BALLOON WAS INFLATED IN THE RIGHT RETROPERITONEAL CAVITY. A PLAN WAS DEVELOPED BETWEEN THE ANTERIOR SPINE AND VENA CAVA AS WELL AS ABDOMINAL AORTA WITH SEGMENTAL VESSELS LIGATION. STRUCTURES AT RISK WERE SAFELY PROTECTED UNDER ENDOSCOPY DURING HORIZONTAL OR SAGITTAL OSTEOTOMIES. RESULTS: FROM 2021, SEVEN PATIENTS AGED A MEDIAN 52 YEARS OLD (RANGE, 34¿67) WERE INCLUDED. INVOLVED SPINAL SEGMENTS WENT FROM T11 TO L3. SURGERY WAS ABORTED IN ONE CASE DUE TO MASSIVE BLEEDING AND VENTILATING DIFFICULTIES. THERE WERE TWO PARTIAL AND FOUR TOTAL VERTEBRAL RESECTIONS. MEDIAN OPERATING DURATION AND ESTIMATED BLOOD LOSS WERE 405 MIN (RANGE, 360¿540) AND 2.1 L (RANGE, 1.2¿19), RESPECTIVELY. POSTOPERATIVE COMPLICATIONS CONSISTED OF 1 URINARY INFECTION; 1 TRANSIENT URINARY RETENTION; 1 POSTERIOR WOUND INFECTION; 1 PNEUMOTHORAX; 1 PERSISTENT PARTIAL MOTOR DEFICIT; 1 TRANSIENT CONFUSION; 1 PULMONARY EMBOLISM; 1 CSF LEAK; 1 SUBDURAL HEMATOMA; 1 RETROPERITONEAL LYMPHOCELE. ALL MARGINS WERE UNCONTAMINATED. ALL PATIENTS WERE ALIVE AND AMBULATORY AT LAST FOLLOW-UP. CONCLUSION: EARLY RESULTS SUGGEST EN BLOC RESECTION ASSISTED BY RETROPERITONEAL VIDEOSCOPY IN TUMORS FROM T11 TO L3/4 DISK SPACE IS FEASIBLE, LESS INVASIVE AND SAFE. CAREFUL SURGICAL PLANNING AND EXPERIENCE IN ENDOSCOPIC VASCULAR SURGERY ARE MANDATORY. REPORTED EVENT(S): PATIENT 3 (FEMALE, 41 YEARS OLD) EXPERIENCED A 3/5 RIGHT QUADRICEPS MOTOR DEFICIT AND WAS NOT FULLY RECOVERED AT LAST FOLLOW-UP. EXPERIENCED UNEXPECTED PERSISTENT POSTOPERATIVE NEUROLOGICAL DEFICIT WAS ABLE TO AMBULATE WITH ONE CRUTCH. THE PATIENT EXPERIENCED URINARY RETENTION AND PERSISTENT 3/5 MOTOR WEAKNESS IN RIGHT QUADRICEPS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2052099 | O-ARM IMAGING SYSTEM | IMAGE-INTENSIFIED FLUOROSCOPIC X-RAY SYSTEM, M | OXO | MEDTRONIC NAVIGATION, INC. (BOXBOROUGH) | UNK_OARM_SYS |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 41 YR | Female | Required Intervention| H |