FDA Adverse Event Malfunction Summary report: N

HEMODIALYSIS BLOODLINES

MDR report key: 22726434 · Received August 6, 2025

Report

Report Number
2521402-2025-00342
Event Type
Malfunction
Date Received
August 6, 2025
Report Date
November 12, 2025
Manufacturer
B. BRAUN MEDICAL INC.
Product Code
FJK
UDI-DI
04046964367786
PMA / PMN Number
K080807
Removal / Correction Number
Z-0070-2026
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MN, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

EVENT 2. ADDITIONAL INFORMATION: D9 DEVICE RETURNED TO MANUFACTURER DATE THIS REPORT HAS BEEN IDENTIFIED AS B. BRAUN MEDICAL INTERNAL REPORT NUMBER (B)(4). ONE (1) USED SAMPLE WAS RETURNED FOR EVALUATION. THROUGH VISUAL EXAMINATION, NO VISUAL DEFECTS WERE IDENTIFIED. THE SAMPLE WAS SUBJECTED TO A LEAK TEST PER SPECIFICATION WITH PASSING RESULTS. ALTHOUGH NO SAMPLES WERE PROVIDED, THE REPORTED EVENT IS SIMILAR TO A KNOWN ISSUE OF AIR IN LINE DURING USE. A REVIEW OF THE DEVICE HISTORY RECORD (DHR) WAS PERFORMED FOR THE REPORTED LOT NUMBER AND NO ABNORMALITIES OR NON-CONFORMANCES WERE NOTED DURING THE IN PROCESS OR FINAL PRODUCT INSPECTION. THE REPORTED ISSUE IS DUE TO A MANUFACTURING ISSUE WITH THE ARTERIAL AND VENOUS PATIENT CONNECTORS, WHICH MAY ALLOW AIR LEAKAGE RESULTING IN MICROBUBBLES IN THE LINE, WHICH COULD THUS TRIGGER AIR-IN-LINE ALARMS. AN APPROVED PROJECT IS IN PLACE TO FURTHER ADDRESS ISSUES WITH AIR IN LINE. ADDITIONALLY, B. BRAUN MEDICAL INC. (BBMI) ISSUED A VOLUNTARY URGENT FIELD SAFETY CORRECTION FOR STREAMLINE® BLOODLINE SET FOR DIALOG+® HEMODIALYSIS SYSTEM (2521402-9/3/25-004-C [Z-0070-2026]). WE WILL MAINTAIN THIS REPORT FOR FURTHER REFERENCES AND CONTINUE TO MONITOR OTHER REPORTS FOR SIMILAR OCCURRENCES. IF ANY ADDITIONAL PERTINENT INFORMATION BECOMES AVAILABLE, A FOLLOW UP WILL BE SUBMITTED.

Additional Manufacturer Narrative · 0

THIS REPORT HAS BEEN IDENTIFIED AS B. BRAUN MEDICAL INTERNAL REPORT NUMBER (B)(4). THE INVESTIGATION IS ONGOING AT THIS TIME. A FOLLOW-UP WILL BE SUBMITTED WHEN THE INVESTIGATION RESULTS BECOME AVAILABLE.

Description of Event or Problem · 0

AS REPORTED BY THE USER FACILITY: EVENT 2: BRIEF INQUIRY DESCRIPTION, BLOOD TUBING FAILURE DURING TEST. DETAILED INQUIRY DESCRIPTION: GOOD MORNING, YEMI I THINK WE HAVE A BAD BATCH OF TUBING IN MORRIS-SO FAR THIS MORNING WE HAVE HAD 5 SETS OF TUBING FAIL THE BLOOD SIDE TESTS (EVEN AFTER INCREASING BLOOD PUMP SPEED TO GET OUT BUBBLES IN THE TUBING IN PUMP, MANIPULATING POD VOLUMES, CLEANING VENOUS SENSOR, TIGHTENING ALL CONNECTIONS, ETC.). LOT # A2500133.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1533145 HEMODIALYSIS BLOODLINES SET, TUBING, BLOOD, WITH AND WITHOUT ANTI-REGURGITATION VALVE FJK B. BRAUN MEDICAL INC. A2500133 04046964367786

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown