HEMODIALYSIS BLOODLINES
Report
- Report Number
- 2521402-2025-00343
- Event Type
- Malfunction
- Date Received
- August 6, 2025
- Report Date
- November 12, 2025
- Manufacturer
- B. BRAUN MEDICAL INC.
- Product Code
- FJK
- UDI-DI
- 04046964367786
- PMA / PMN Number
- K080807
- Removal / Correction Number
- Z-0070-2026
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MN, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
THIS REPORT HAS BEEN IDENTIFIED AS B. BRAUN MEDICAL INTERNAL REPORT NUMBER (B)(4). THE INVESTIGATION IS ONGOING AT THIS TIME. A FOLLOW-UP WILL BE SUBMITTED WHEN THE INVESTIGATION RESULTS BECOME AVAILABLE.
EVENT 3: ADDITIONAL INFORMATION: D9 DEVICE RETURNED TO MANUFACTURER DATE. THIS REPORT HAS BEEN IDENTIFIED AS B. BRAUN MEDICAL INTERNAL REPORT NUMBER (B)(4). ONE (1) USED SAMPLE WAS RETURNED FOR EVALUATION. THROUGH VISUAL EXAMINATION, NO VISUAL DEFECTS WERE IDENTIFIED. THE SAMPLE WAS SUBJECTED TO A LEAK TEST PER SPECIFICATION WITH PASSING RESULTS. ALTHOUGH NO SAMPLES WERE PROVIDED, THE REPORTED EVENT IS SIMILAR TO A KNOWN ISSUE OF AIR IN LINE DURING USE. A REVIEW OF THE DEVICE HISTORY RECORD (DHR) WAS PERFORMED FOR THE REPORTED LOT NUMBER AND NO ABNORMALITIES OR NON-CONFORMANCES WERE NOTED DURING THE IN PROCESS OR FINAL PRODUCT INSPECTION. THE REPORTED ISSUE IS DUE TO A MANUFACTURING ISSUE WITH THE ARTERIAL AND VENOUS PATIENT CONNECTORS, WHICH MAY ALLOW AIR LEAKAGE RESULTING IN MICROBUBBLES IN THE LINE, WHICH COULD THUS TRIGGER AIR-IN-LINE ALARMS. AN APPROVED PROJECT IS IN PLACE TO FURTHER ADDRESS ISSUES WITH AIR IN LINE. ADDITIONALLY, B. BRAUN MEDICAL INC. (BBMI) ISSUED A VOLUNTARY URGENT FIELD SAFETY CORRECTION FOR STREAMLINE® BLOODLINE SET FOR DIALOG+® HEMODIALYSIS SYSTEM (2521402-9/3/25-004-C [Z-0070-2026]). WE WILL MAINTAIN THIS REPORT FOR FURTHER REFERENCES AND CONTINUE TO MONITOR OTHER REPORTS FOR SIMILAR OCCURRENCES. IF ANY ADDITIONAL PERTINENT INFORMATION BECOMES AVAILABLE, A FOLLOW UP WILL BE SUBMITTED.
AS REPORTED BY THE USER FACILITY: EVENT 3. BRIEF INQUIRY DESCRIPTION: BLOOD TUBING FAILURE DURING TEST. DETAILED INQUIRY DESCRIPTION: GOOD MORNING, (B)(6) I THINK WE HAVE A BAD BATCH OF TUBING IN MORRIS-SO FAR THIS MORNING WE HAVE HAD 5 SETS OF TUBING FAIL THE BLOOD SIDE TESTS (EVEN AFTER INCREASING BLOOD PUMP SPEED TO GET OUT BUBBLES IN THE TUBING IN PUMP, MANIPULATING POD VOLUMES, CLEANING VENOUS SENSOR, TIGHTENING ALL CONNECTIONS, ETC.). LOT # A2500133.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1533142 | HEMODIALYSIS BLOODLINES | SET, TUBING, BLOOD, WITH AND WITHOUT ANTI-REGURGITATION VALVE | FJK | B. BRAUN MEDICAL INC. | A2500133 | 04046964367786 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |