FDA Adverse Event Malfunction Summary report: N

TRUSTEEL

MDR report key: 22584525 · Received July 24, 2025

Report

Report Number
3003442380-2025-11843
Event Type
Malfunction
Date Received
July 24, 2025
Date of Event
June 7, 2025
Report Date
October 13, 2025
Manufacturer
UNOMEDICAL DEVICES S.A. DE C.V.
Product Code
FPA
UDI-DI
05705244018457
PMA / PMN Number
K041545
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

INITIAL AND FINAL MDR (B)(4) -DEVICE 1 OF 2.

Additional Manufacturer Narrative · 0

SUPPLEMENTAL REPORT 01 - (B)(4) - MDR 3003442380-2025-11843. ADDITIONAL INFORMATION - THIS MDR IS BEING SUBMITTED TO INCLUDE THE BELOW: H6: INVESTIGATION RESULTS UNDER TYPE OF INVESTIGATION, INVESTIGATION FINDINGS, INVESTIGATION CONCLUSIONS. H11: INVESTIGATION SUMMARY. PER REVISION 21 OF PROCEDURE (B)(4), A CHILD INVESTIGATION IS NOT REQUIRED TO DOCUMENT THE DHR REVIEW FOR A TYPE 2 REPORTABLE COMPLAINT. HOWEVER, THE CHILD WAS CREATED TO ALLOW THE PARENT RECORD TO ADVANCE TO REVIEW AND SUMMARY. SINCE IT WAS CREATED, THE DHR REVIEW WAS DOCUMENTED WITHIN THE CHILD. COMPLAINT INVESTIGATION RESULTS: A COMPLAINT INVESTIGATION HAS BEEN INITIATED UNDER COMPLAINT INVESTIGATION CHILD RECORD (B)(4). THE BATCH 6013089, IN QUESTION WAS MANUFACTURED AT THE REYNOSA SITE. DEVICE HISTORY RECORD (DHR) REVIEW: THE LOT 6013089 WAS MANUFACTURED ACCORDING TO THE WORK INSTRUCTION (WI) VERSION 46 AND MANUFACTURED IN THE MULTIVAC 14 ON 30/APR/2025, WITH A TOTAL OF (B)(4) UNITS. GLUE-CONNECTOR LOT: THE LOT 5D03566 WAS MANUFACTURED ACCORDING TO THE WI VERSION 39 AND MANUFACTURED IN THE MACHINE MP03 ON 27/APR/2025, WITH A TOTAL OF (B)(4) UNITS. THE LOT 5D03567 WAS MANUFACTURED ACCORDING TO THE WI VERSION 39 AND MANUFACTURED IN THE MACHINE MP03 ON 28/APR/2025, WITH A TOTAL OF (B)(4) UNITS. THE LOT 5D03568 WAS MANUFACTURED ACCORDING TO THE WI VERSION 39 AND MANUFACTURED IN THE MACHINE MP03 ON 29/APR/2025, WITH A TOTAL OF (B)(4) UNITS. THE LOT 5D03569 WAS MANUFACTURED ACCORDING TO THE WI VERSION 39 AND MANUFACTURED IN THE MACHINE MP03 ON 01/MAY/2025, WITH A TOTAL OF (B)(4) UNITS. THE LOT 5D03697 WAS MANUFACTURED ACCORDING TO THE WI VERSION 39 AND MANUFACTURED IN THE MACHINE MP07 ON 22/APR/2025, WITH A TOTAL OF (B)(4) UNITS. THE LOT 5C04822 WAS MANUFACTURED ACCORDING TO THE WI VERSION 39 AND MANUFACTURED IN THE MACHINE MP07 ON 22/APR/2025, WITH A TOTAL OF (B)(4) UNITS. REVIEW OF THE DHR SHOWED THAT ALL RELEVANT TESTS REQUIRED DURING THE RELATED PROCESSES HAD BEEN FULFILLED AND MET THE REQUIREMENTS. NO DEVIATION WAS IDENTIFIED, NOR MAINTENANCE EVENTS WERE RECORDED RELATED TO COMPLAINT CODE. CONCLUSION SUMMARY OF COMPLAINT INVESTIGATION: AS A RESULT OF THE FOLLOWING: TWO EXTENDED WAS RAISED DURING THE PROCESS UNRELATED TO THE MALFUNCTION REPORTED, THEREFORE, NO NON-CONFORMANCE (NC) RAISED DURING PRODUCTION RELATED TO COMPLAINT CODE, NO FURTHER ACTIONS ARE REQUIRED. THIS COMPLAINT WILL NOT REQUIRE FURTHER ROOT CAUSE INVESTIGATION NOR CORRECTIVE AND PREVENTIVE ACTION (CAPA) PLAN. THEREFORE, THIS ISSUE WILL BE MONITORED THROUGH THE POST MARKET SURVEILLANCE ACTIVITIES.

Description of Event or Problem · 0

REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES. IT WAS REPORTED THAT PATIENT FACED TWO INFUSION SET CANNULA WAS BENT ON (B)(6) 2025 AND (B)(6) 2025. THE INSERTION SITE WAS ABDOMEN. THE PATIENT REPLACED INFUSION SETS AND RESUMED INSULIN SUCCESSFULLY. NO FURTHER INFORMATION AVAILABLE.

Description of Event or Problem · 0

TO DATE NO ADDITIONAL PATIENT OR EVENT DETAILS HAVE BEEN RECEIVED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1591223 TRUSTEEL UNO CONTACT DETACH G29 60/6TCAP 10PK INT FPA UNOMEDICAL DEVICES S.A. DE C.V. 1002834 6013089 05705244018457

Patients

Seq Age Sex Outcome Treatment
1 44 YR Female