MGIT SERIES 960 AST SIRE
Report
- Report Number
- 1119779-2025-01772
- Event Type
- Malfunction
- Date Received
- July 21, 2025
- Date of Event
- November 24, 2023
- Report Date
- June 12, 2025
- Manufacturer
- BECTON DICKINSON & CO. (SPARKS)
- Product Code
- MJA
- UDI-DI
- 00382902451235
- PMA / PMN Number
- K003062
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MY
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
INVESTIGATION SUMMARY: THE BATCH HISTORY RECORD REVIEWS FOR THE KIT AND EACH OF ITS COMPONENTS WERE SATISFACTORY AND NO NOTIFICATIONS WERE GENERATED. THE COMPLAINT HISTORY WAS REVIEWED, AND NO OTHER COMPLAINTS HAVE BEEN TAKEN ON THIS KIT BATCH. RETENTION SAMPLES FROM SIRE SUPPLEMENT BATCH 3075925 (10 VIALS), STREPTOMYCIN BATCH 3075919 (10 VIALS), ISONIAZID BATCH 3075920 (10 VIALS), RIFAMPIN BATCH 3075921 (10 VIALS) AND ETHAMBUTOL BATCH 3075922 (10 VIALS) WERE AVAILABLE FOR INSPECTION. SUPPLEMENT BATCH 3095925 WAS TESTED ALONG WITH EACH OF THE KIT COMPONENT DRUGS FOR SUSCEPTIBILITY AGAINST THE ORGANISMS LISTED IN CERTIFICATE OF ANALYSIS. MGIT 7ML (MATERIAL 245122) TUBE BATCH 3103446 SAMPLES ALSO WERE AVAILABLE FOR USE IN THE TESTING INVESTIGATION. MYCOBACTERIUM TUBERCULOSIS H37RV ATCC 27294 WAS SENSITIVE TO STREPTOMYCIN BATCH 3075919, ISONIAZID BATCH 3075920, RIFAMPIN BATCH 3075921 AND ETHAMBUTOL BATCH 3075922 AS EXPECTED. MYCOBACTERIUM TUBERCULOSIS ATCC 35820 WAS RESISTANT TO STREPTOMYCIN BATCH 3075919 AS EXPECTED. MYCOBACTERIUM TUBERCULOSIS ATCC 35822 WAS RESISTANT TO ISONIAZID BATCH 3075920 AS EXPECTED. MYCOBACTERIUM TUBERCULOSIS ATCC 35838 WAS RESISTANT TO RIFAMPIN BATCH 3075921 AS EXPECTED. MYCOBACTERIUM TUBERCULOSIS ATCC 35837 WAS RESISTANT TO ETHAMBUTOL BATCH 3075922 AS EXPECTED. GROWTH CONTROLS FOR EACH ORGANISM TESTED HAD SATISFACTORY GROWTH DETECTED. NO RETURN SAMPLES OR PHOTOS WERE RECEIVED FOR INVESTIGATION. NO PERFORMANCE DEFECTS WERE OBSERVED FROM TESTING OF RETENTION SAMPLES OF MGIT SIRE KIT BATCH 3122877 COMPONENTS. NO PRODUCT DEFECT WAS FOUND FROM THE INVESTIGATION OF THIS COMPLAINT. THIS COMPLAINT CANNOT BE CONFIRMED. BD WILL CONTINUE TO TREND COMPLAINTS FOR PERFORMANCE. THIS MDR IS BEING SUBMITTED AS PART OF A RETROSPECTIVE REVIEW OF RECORDS DATING APRIL 2023-2025, UNDER CAPA 11910483.
IT WAS REPORTED WHILE USING MGIT SERIES 960 AST SIRE, THERE WAS A LOW MIC RESULT FOR PATIENT SAMPLE. THERE WAS NO REPORT OF PATIENT IMPACT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2036346 | MGIT SERIES 960 AST SIRE | SUSCEPTIBILITY TEST POWDERS, ANTIMYCOBACTERIAL | MJA | BECTON DICKINSON & CO. (SPARKS) | 3122877 | 00382902451235 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |