FDA Adverse Event Malfunction Summary report: N

DIRECTLINK ICP MODULE

MDR report key: 22472309 · Received July 10, 2025

Report

Report Number
3013886523-2025-00165
Event Type
Malfunction
Date Received
July 10, 2025
Report Date
October 2, 2025
Manufacturer
INTEGRA LIFESCIENCES SWITZERLAND SAR
Product Code
GWM
PMA / PMN Number
K152670
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

AN INVESTIGATION HAS BEEN INITIATED BASED ON THE REPORTED INFORMATION. UPON COMPLETION OF THE INVESTIGATION, A FOLLOW-UP REPORT WILL BE SUBMITTED.

Additional Manufacturer Narrative · 0

UPDATED FIELDS: D4, D9, G3, G6, H2, H3, H4, H6, H11 THE DIRECRTLINK MODULE WAS NOT RETURNED FOR EVALUATION; THEREFORE, AN EVALUATION OF THE DEVICE COULD NOT BE PERFORMED. LOT NUMBER INFORMATION HAS BEEN PROVIDED; THEREFORE, DEVICE HISTORY RECORD (DHR) WAS REVIEWED, AND NO ANOMALIES WERE FOUND. THE ROOT CAUSE(S) OF THE REPORTED ISSUE COULD NOT BE DETERMINED. IF ADDITIONAL RELEVANT INFORMATION BECOMES AVAILABLE IN THE FUTURE, THIS COMPLAINT WILL BE REOPENED, AND THE RESPECTIVE EVALUATION PERFORMED. TRENDS WILL BE MONITORED FOR THIS AND SIMILAR ISSUES. AT PRESENT, WE CONSIDER THIS COMPLAINT TO BE CLOSED.

Description of Event or Problem · 0

2 OF 6 REPORTS. OTHER MFG REPORT NUMBERS: 3013886523-2025-00164, 3013886523-2025-00166, 3013886523-2025-00167, 3013886523-2025-00168, 3013886523-2025-00169. THIS REPORT IS FOR THE 1ST EVENT (DIRECTLINK ICP MODULE) A PHYSICIAN EXPRESSED A LOSS OF CONFIDENCE IN CERELINK ICP SENSORS. THEY ESTIMATE THAT IN 50% OF THE CASES WHERE A PATIENT HAD AN CERELINK ICP SENSOR AND A CHECK OF ICP WITH A FFT (FLUID FILLED TRANSDUCER) VIA THE EXTERNAL DRAINAGE SYSTEM THEY NOTICED A DECLINE AND DIFFERENCE THAT BECOMES BIGGER AND BIGGER (CFR DRIFT) AFTER A COUPLE OF DAYS. THEY DOUBLE CHECK THE FFT MEASUREMENT AS THIS IS POSITIONING (HIGHT) DEPENDANT, HOWEVER DON'T NOTICE MISTAKES WITH EVD SYSTEM, SO THEY CONCLUDED WRONG MEASUREMENT OF CERLINK SENSOR (USE THIS TOGETHER WITH DIRECTLINK). ADDITIONAL INFORMATION RECEIVED: IS IT POSSIBLE TO KNOW HOW MANY TIMES THIS TYPE OF DYSFUNCTION WAS OBSERVED? IF YES, HOW MANY AND APPROXIMATE DATE? ANSWER: THEY ESTIMATE50% OF THE CASE, AND AS I COUNT 38 PROBES SINCE 2023. I BELIEVE18 WOULD BE AN EDUCATED ESTIMATION. FOR EACH CASE, DID THEY REMOVE THE SENSOR? HOW DID THEY FOLLOW THE MONITORING? ANSWER: THEY NOTICED THE INCONSISTENCY AS THEY SIMULTANEOUSLY MEASURED ICP WITH A FLUID FILLED TRANSDUCER ON THEIR SYSTEM FOR EXTERNAL DRAINAGE. SO, THEY KEPT THE SENSOR IN AS LONG AS POSSIBLE TO KEEP MEASURING ICP IN 2 WAYS, RELYING MORE ON FFT THAN CERELINK FOR EACH PATIENT, WERE THERE ANY CONSEQUENCES? IF YES, PLEASE DESCRIBE. ANSWER: FOR SOME PATIENT THEY SAW THAT THE ICP WAVE WAS ¿FLATTENED¿, AND AS A CONSEQUENCE NOT RELIABLE ANYMORE SO THEY SWITCHED TO EVD (PROBABLY EARLIER) SO SOME OF THOSE PROCEDURES COULD HAVE BEEN AVOIDED IF SENSOR WAS WORKING AS EXPECTED. (THEN A PLACEMENT OF EXTERNAL DRAINAGE COULD HAVE BEEN AVOIDED.

Description of Event or Problem · 0

N/A.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1678314 DIRECTLINK ICP MODULE DIRECTLINK - MODULE GWM INTEGRA LIFESCIENCES SWITZERLAND SAR

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown