FDA Adverse Event Malfunction Summary report: N

TRANSPORT STRETCHER

MDR report key: 2243482 · Received August 19, 2011

Report

Report Number
3006697241-2011-00084
Event Type
Malfunction
Date Received
August 19, 2011
Date of Event
July 22, 2011
Report Date
July 22, 2011
Manufacturer
HILL-ROM DE MEXICO S DE RL DE CV
Product Code
FPO
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

REPAIRS HAVE NOT BEEN COMPLETED.

Description of Event or Problem · 1

INFO RECEIVED INDICATES THAT A NURSE AT (B)(6) HOSP SLIPPED AND FELL WHILE PUSHING A STRETCHER WITH A PT ON IT AND THE PT FELL OUT OF THE STRETCHER AS WELL. NO INJURY. THE ACCOUNT STATED THAT THE STEER CASTER ON THE STRETCHER WAS SHAKING, WHICH CAUSED THE NURSE TO LOSE CONTROL OF THE STRETCHER. THE STRETCHER WAS SHAKING SO MUCH THAT THE PT'S LEG STARTED TO FALL OFF THE STRETCHER. THE STEER CASTER WAS LOCKED OPPOSITE OF THE OTHER THREE CASTERS WHICH WERE IN THE TRAILING POSITION. THE POSITION OF THE STEER CASTER WAS THE CAUSE OF THE SHAKING.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 TRANSPORT STRETCHER WHEELED STRETCHER FPO HILL-ROM DE MEXICO S DE RL DE CV 8005

Patients

Seq Age Sex Outcome Treatment
1 UNK