BIOFLO PICC 3F SL-55CM MST-70 KIT VALVED PG
Report
- Report Number
- 3030714660-2025-00007
- Event Type
- Malfunction
- Date Received
- June 30, 2025
- Date of Event
- June 2, 2025
- Report Date
- June 30, 2025
- Manufacturer
- SPECTRUM VASCULAR
- Product Code
- LJS
- UDI-DI
- H965458020
- PMA / PMN Number
- K150448
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- NY, US
- Reporter Occupation
- NURSE
- Health Professional
- Yes
Narratives
AS THE REPORTED DEVICE WAS NOT RETURNED, A DEVICE EVALUATION IS UNABLE TO BE PERFORMED. INVESTIGATION WAS COMPLETED BASED ON INFORMATION RECEIVED TO DATE. IF COMPLAINT SAMPLE OR ADDITIONAL INFORMATION IS RECEIVED AND WARRANTS FURTHER INVESTIGATION, THEN COMPLAINT FILE WILL BE REOPENED AND UPDATED ACCORDINGLY. A LOT NUMBER WAS NOT PROVIDED/AVAILABLE TO BE ABLE TO CONDUCT A DHR REVIEW, THEREFORE A DEFINITIVE ROOT CAUSE COULD NOT BE DETERMINED. THE MOST LIKELY ROOT CAUSE FOR A CRACKED FEMALE VALVE HOUSING IS DUE TO AN OVER TIGHTENED CONNECTION WITH A MATING MALE LUER (LIKELY A NEEDLELESS CONNECTOR) AND/OR INADEQUATE FLUSHING. A CONTRIBUTING FACTOR TO THE OVER-TIGHTENED CONNECTION MAY BE THE MECHANICS/HAND PLACEMENT DURING INFUSION ACCESS. IT IS PREFERABLE TO GRASP THE NEEDLELESS CONNECTOR (NC) WHEN CONNECTING A SYRINGE/TUBING TO IT RATHER THAN GRASPING THE LUER HUB WHILE MAKING A CONNECTION WITH THE NC. GRASPING THE LUER HUB WHILE CONNECTING A SYRINGE/TUBING SET TO THE NC CAN TRANSMIT ADDITIONAL TORQUE TO THE FEMALE LUER HUB. INADEQUATE FLUSHING OF THE DEVICE LUMEN MAY ALSO BE A CONTRIBUTING FACTOR. AN INSTRUCTIONAL VIDEO HAS BEEN CREATED REGARDING THE CARE AND MAINTENANCE OF THE BIOFLO PICC; REFERENCE YOUTUBE VIDEO, "ANGIODYNAMICS BIOFLO PICC CARE AND MAINTENANCE INSTRUCTIONAL VIDEO" UPLOADED ON NOVEMBER 18, 2020. THIS VIDEO IS INTENDED AS A VISUAL REPRESENTATION OF INFORMATION PROVIDED IN THE DFU FOR CLINICIANS WHO ARE RESPONSIBLE FOR THE CARE AND MAINTENANCE OF PICCS BUT ARE NOT RESPONSIBLE FOR PICC PLACEMENT. LABELING REVIEW: THE DFU THAT IS SUPPLIED IN BIOFLO KITS ITEM NUMBER (16600224-01) CONTAINS THE FOLLOWING PRECAUTION: IT IS RECOMMENDED THAT ONLY LUER LOCK ACCESSORIES BE USED WITH THE BIOFLO PICC WITH ENDEXO AND PASV VALVE TECHNOLOGY. REPEATED OVER-TIGHTENING MAY REDUCE HUB CONNECTOR LIFE. DO NOT USE HEMOSTATS TO SECURE OR REMOVE DEVICES WITH LUER LOCK HUB CONNECTIONS. FLUSHING - RECOMMENDED PROCEDURE 1. FLUSH THE CATHETER AFTER EVERY USE, OR AT LEAST EVERY SEVEN DAYS WHEN NOT IN USE, TO MAINTAIN PATENCY. USE A 10 ML SYRINGE OR LARGER. 2. FLUSH THE CATHETER WITH A MINIMUM OF 10 ML OF STERILE NORMAL SALINE, USING A "PULSE" OR "STOP/START" TECHNIQUE. WARNING: IF USING BACTERIOSTATIC SALINE, DO NOT EXCEED 30 ML IN A 24-HOUR PERIOD. 3. DISCONNECT THE SYRINGE AND ATTACH A STERILE END CAP TO EACH LUER LOCK HUB. NOTE: THIS IS THE RECOMMENDED FLUSH PROCEDURE FOR THIS CATHETER. IF USING A DIFFERENT PROCEDURE THAN LISTED ABOVE, THE USE OF HEPARIN MAY BE NECESSARY. FOLLOW INSTITUTIONAL PROTOCOL FOR CATHETER FLUSHING. PRECAUTION: INCOMPATIBLE DRUG DELIVERY WITHIN THE SAME LUMEN MAY CAUSE PRECIPITATION. ENSURE THAT THE CATHETER LUMEN IS FLUSHED FOLLOWING EACH INFUSION. PRECAUTION: IF RESISTANCE IS MET WHEN FLUSHING, IT IS RECOMMENDED THAT NO FURTHER ATTEMPTS BE MADE. FURTHER FLUSHING MAY RESULT IN CATHETER RUPTURE. REFER TO INSTITUTIONAL PROTOCOL FOR CLEARING OCCLUDED CATHETERS. PRECAUTION: PLACE A CAP ON THE HUB AFTER USE TO REDUCE THE RISK OF CONTAMINATION. A REVIEW OF SIMILAR COMPLAINTS NOTED NO ADVERSE TRENDS FOR THIS COMPLAINT TYPE AND PRODUCT FAMILY. THIS TYPE OF COMPLAINT WILL CONTINUE TO BE MONITORED FOR TRENDS. REFERENCE (B)(4).
AN END USER EXPERIENCED AN ISSUE WHEN USING A BIOFLO PICC 3F SL-55CM MST-70 KIT VALVED PG. POST PLACEMENT, IT WAS NOTED THE HUB WAS CRACKED. THE PICC REQUIRED REMOVAL AND WAS REPLACED. THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS OR HARM BECAUSE OF THIS INCIDENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2360304 | BIOFLO PICC 3F SL-55CM MST-70 KIT VALVED PG | PERIPHERALLY INSERTED CENTRAL CATHETER | LJS | SPECTRUM VASCULAR | H965458020 | H965458020 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |