HLED
Report
- Report Number
- 9710055-2025-0000171
- Event Type
- Malfunction
- Date Received
- June 30, 2025
- Report Date
- June 30, 2025
- Manufacturer
- MAQUET SAS
- Product Code
- FSY
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- BR
- Reporter Occupation
- OTHER
Narratives
EVENT SITE NAME: 200115-01 - (B)(6) HOSPITAL. EVENT SITE POSTAL CODE: (B)(6). EVENT SITE TELEPHONE: (B)(6). EVENT SITE ADDRESS LINE 2: (B)(6). THE UNIQUE IDENTIFIER (UDI) # INFORMATION IS NOT AVAILABLE AS THIS MEDICAL DEVICE/MODEL WAS MARKETED AND/OR DISCONTINUED IN US BEFORE THE UDI REQUIREMENT BECAME MANDATORY. INITIAL REPORTER: CLINICAL ENGINEER. GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF SURGICAL LIGHTS - HLED. IT WAS STATED AND CONFIRMED BY PHOTOGRAPHIC EVIDENCE THAT THE PAINT WAS CHIPPING FROM FORK. WE DECIDED TO REPORT THE ISSUE IN ABUNDANCE OF CAUTION AS ANY PAINT PARTICLES FALLING OFF INTO STERILE FIELD OR DURING PROCEDURE MAY CAUSE CONTAMINATION. BASED ON THE INFORMATION COLLECTED, IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE SURGICAL LIGHTS DID NOT MEET ITS SPECIFICATION, SINCE PAINT CHIPPING COULD BE CONSIDERED AS TECHNICAL DEFICIENCIES, AND IN THIS WAY THE DEVICE CONTRIBUTED TO EVENT. IT IS UNKNOWN IF CLAIMED DEVICES WERE OR WERE NOT BEING USED FOR PATIENT TREATMENT OR DIAGNOSIS WHEN THE EVENT TOOK PLACE. A ROOT CAUSE ANALYSIS FOR PAINT PEELING PROBLEM WAS PERFORMED BY SUBJECT MATTER EXPERTS AND CONCLUDED THAT ALL MAQUET SAS PRODUCTS COMPLY WITH: CURRENT VERSION OF IEC 60601-1 GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE. CURRENT VERSION OF IEC 60601-2-41 PARTICULAR REQUIREMENTS FOR THE SAFETY OF SURGICAL LUMINAIRES AND LUMINAIRE FOR DIAGNOSIS. PAINT DEFINITION PFC066. THIS PROCEDURE DEFINES MAQUET SAS¿S REQUIREMENTS FOR ALL PAINTED PARTS. DISINFECTION PRODUCTS TEST: THE AIM OF THESE TESTS IS TO DETECT ANY INCOMPATIBILITY WITH DISINFECTANT. THE PAINT CHIP OR PAINT DAMAGES ARE DUE TO: IMPACTS, COLLISIONS (ABNORMAL USE). THE OPERATING MANUAL INCLUDES THE INSTRUCTIONS TO PRE-POSITION THE ARMS PRIOR TO USE, IN ORDER TO PREVENT DAMAGES. TO PREVENT ANY SIMILAR INCIDENT, IT IS RECOMMENDED TO AVOID COLLISIONS BETWEEN DEVICES. VISUAL INSPECTIONS DURING THE CLEANING ALLOW TO DETECT THE PAINTING DEFECT, WE RECOMMEND TO PERFORM CORRECTIVE MAINTENANCE TO RECTIFY THE DEFAULT AFTER ITS DETECTION. MINOR PAINT CHIP CAN BE REPAIRED WITH TOUCH UP PAINT, NEVERTHELESS, THE PARTS IMPACTED BY SERIOUS DAMAGE MUST BE REPLACED. GETINGE SHALL CONTINUE TO MONITOR FOR ANY FURTHER EVENTS OF THIS NATURE AND DOES NOT PROPOSE ANY FURTHER ACTION AT THIS TIME.
GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF SURGICAL LIGHTS - HLED. IT WAS STATED AND CONFIRMED BY PHOTOGRAPHIC EVIDENCE THAT THE PAINT WAS CHIPPING FROM FORK. WE DECIDED TO REPORT THE ISSUE IN ABUNDANCE OF CAUTION AS ANY PAINT PARTICLES FALLING OFF INTO STERILE FIELD OR DURING PROCEDURE MAY CAUSE CONTAMINATION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 969638 | HLED | LIGHT, SURGICAL, CEILING MOUNTED | FSY | MAQUET SAS | ARDHLD209000A |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |