FDA Adverse Event Injury Summary report: N

STARCLOSE VASCULAR CLOSURE SYSTEM

MDR report key: 2233592 · Received September 2, 2011

Report

Report Number
2024168-2011-06151
Event Type
Injury
Date Received
September 2, 2011
Date of Event
January 1, 2004
Report Date
August 8, 2011
Manufacturer
AV-TEMECULA-CT
Product Code
MGB
PMA / PMN Number
P050007
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
GR
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

(B)(4). A THOROUGH ANALYSIS COULD NOT BE PERFORMED ON THE PRODUCT BECAUSE IT WAS NOT RETURNED TO ABBOTT VASCULAR FOR INVESTIGATION. THE REPORTED MAJOR RETROPERITONEAL HEMATOMA OCCURRED AFTER INITIAL SUCCESSFUL CLIP DEPLOYMENT. IN THIS CASE, THERE WAS NO REPORTED PRODUCT DEFICIENCY. A RELATIONSHIP BETWEEN THE PATIENT EFFECT AND THE PRODUCT COULD NOT BE ESTABLISHED. HOWEVER, IT WAS REPORTED THAT THE VESSEL OF THE PATIENT WAS HEAVILY CALCIFIED, WHICH IS LISTED UNDER PRECAUTIONS IN THE STARCLOSE INSTRUCTIONS FOR USE (IFU), INSTRUCTING TO NOT DEPLOY THE CLIP IN CALCIFIED AREAS. THEREFORE, THE LIKELY CAUSE FOR THE REPORTED EVENT IS DEVIATION FROM THE IFU. A REVIEW OF THE DEVICE LOT HISTORY RECORD AND A QUERY OF THE COMPLAINT HANDLING DATABASE COULD NOT BE PERFORMED BECAUSE THE LOT NUMBER WAS NOT REPORTED AND THE DEVICE WAS NOT RETURNED FOR ANALYSIS. BASED ON THE REVIEW OF THE EVENT, A PRODUCT QUALITY DEFICIENCY WAS NOT NOTED.

Additional Manufacturer Narrative · 1

(B)(4). DURING PROCESSING OF THIS COMPLAINT, ATTEMPTS WERE MADE TO OBTAIN COMPLETE EVENT, PATIENT AND DEVICE INFORMATION. (B)(6). (DATE OF EVENT): THE PROCEDURES WERE PERFORMED BETWEEN (B)(6) 2004 AND (B)(6) 2009. THE DATE FOR THIS INDIVIDUAL CASE IS NOT KNOWN. (B)(6). THE ARTICLE INDICATES THAT THE MAJOR COMPLICATIONS OCCURRED IN THE EARLY STAGES OF THEIR LEARNING CURVE; IN ADDITION TO LOWER SKILL LEVELS, THEY WERE RELATED TO HIGH PUNCTURE (AT THE LEVEL OF DISTAL IEA) AND MULTIPLE PUNCTURE SITE ATTEMPTS AFFECTING BOTH THE ANTERIOR AND POSTERIOR VESSEL WALLS. NO ADDITIONAL INFORMATION WAS PROVIDED. CONCOMITANT MEDICAL PRODUCTS: SHEATH: 6 FR.; OTHER: CLOPIDOGREL, ASPIRIN, HEPARIN. (B)(4) - IMPROPER OR INCORRECT METHOD (DO NOT DEPLOY THE STARCLOSE CLIP IN AREAS OF CALCIFIED PLAQUE). THE CUSTOMER REPORTED THE DEVICE WAS DISCARDED. THE LOT NUMBER WAS NOT IDENTIFIED; THEREFORE, A DEVICE HISTORY RECORD REVIEW COULD NOT BE PERFORMED. A FOLLOW-UP REPORT WILL BE SUBMITTED WITH RELEVANT INFORMATION. THE SAFETY AND EFFECTIVENESS OF THE STARCLOSE DEVICE HAS NOT BEEN ESTABLISHED IN PATIENTS WITH FEMORAL ARTERY CALCIUM WHICH IS FLUOROSCOPICALLY VISIBLE AT ACCESS SITE. ATTACHMENT, ARTICLE: SAFETY AND EFFICACY OF THE STARCLOSE VASCULAR CLOSURE DEVICE IN MORE THAN 1000 CONSECUTIVE PERIPHERAL ANGIOPLASTY PROCEDURES. STAVROS SPILIOPOULOS, MD, PHD, ET AL; J ENDOVASC THER 2011; 18:435-443. (B)(6).

Description of Event or Problem · 1

THE FOLLOWING EVENT WAS NOTED DURING A LARGE SINGLE-CENTER RETROSPECTIVE STUDY REVIEW (FROM (B)(6) 2004 AND (B)(6) 2009). THE HOSPITAL DATABASE WAS SEARCHED AND 850 PATIENTS WERE COMPARED TO IDENTIFY THE SAFETY AND EFFICACY OF THE STARCLOSE EXTRAVASCULAR CLOSURE DEVICE IN ACHIEVING HEMOSTASIS FOLLOWING A VARIETY OF THERAPEUTIC PERCUTANEOUS PERIPHERAL PROCEDURES USING ANTEGRADE (588) OR RETROGRADE (625) COMMON FEMORAL ARTERY PUNCTURES. A MAJOR RETROPERITONEAL HEMATOMA OCCURRED AFTER INITIALLY SUCCESSFUL CLIP DEPLOYMENT AND ADDITIONAL 5-MINUTE MANUAL COMPRESSION WAS APPLIED IN AN OBESE FEMALE PATIENT AFTER ANTEGRADE PUNCTURE. THE VESSEL CALCIFICATION WAS DESCRIBED AS HEAVY. THE PATIENT WAS TREATED CONSERVATIVELY AND LEFT THE HOSPITAL AFTER 2 DAYS OF ADDITIONAL TREATMENT. FOLLOW-UP INFORMATION RECEIVED FROM THE AUTHOR INDICATED: "THE TERM CONSERVATIVE DESCRIBES THE FACT THAT NO ADDITIONAL PROCEDURE (OPEN SURGICAL OR ENDOVASCULAR) WAS NEEDED AND ADDITIONAL TREATMENT WAS/CONSISTED OF BLOOD TRANSFUSIONS, ANTIBIOTIC THERAPY AND EXTENDED 48H HOSPITALIZATION". PLACEMENT OF THE STARCLOSE DEVICE WAS PERFORMED BY SENIOR INTERVENTIONAL RADIOLOGISTS OR EXPERIENCED FELLOWS AFTER ADEQUATE TRAINING. A 6 FR. SHEATH SIZE WAS USED DURING THE PROCEDURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 STARCLOSE VASCULAR CLOSURE SYSTEM IMPLANTABLE CLIP MGB AV-TEMECULA-CT

Patients

Seq Age Sex Outcome Treatment
1 Hospitalization| R