REPLACEMENT HEART VALVE
Report
- Report Number
- 2015691-2011-16133
- Event Type
- Injury
- Date Received
- September 2, 2011
- Date of Event
- July 14, 2011
- Report Date
- August 5, 2011
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- DYE
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- OTHER
Narratives
THIS DEVICE IS NOT DISTRIBUTED, MARKETED, OR SOLD IN THE U.S.; HOWEVER, IT IS SIMILAR TO MODEL NO. 2800 WHICH IS MARKETED IN THE U.S. DEVICE NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: DESPITE REPEATED ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE DEVICE AND EVENT, NO ADDITIONAL INFORMATION OR SAMPLE FOR EVALUATION WAS RECEIVED. THE DEVICE HISTORY RECORD (DHR) REVIEW WAS COMPLETED AND THIS DEVICE PASSED ALL MANUFACTURING AND STERILIZATION INSPECTIONS WITH NO NONCONFORMANCE.
ADDITIONAL MANUFACTURER NARRATIVE: THROUGH FOLLOW-UP WITH THE HEALTH-CARE PROVIDER, IT WAS LEARNED THAT THE DEVICE WAS EXPLANTED DUE TO PROSTHETIC VALVE ENDOCARDITIS. THERE HAS BEEN NO ALLEGATION OF A PRODUCT MALFUNCTION OR QUALITY DEFICIENCY. UNFORTUNATELY, THE EDWARDS DEVICE WAS NOT RETURNED FOR ANALYSIS. WITHOUT RETURN OF THE DEVICE, AN EVALUATION CANNOT BE PERFORMED TO CONFIRM THE REPORTED EVENT. CONCLUSION: LATE PROSTHETIC VALVE ENDOCARDITIS, OCCURRING MORE THAN 60 DAYS AFTER SURGERY, IS USUALLY CAUSED BY AN INFECTION WHICH OCCURS ELSEWHERE IN THE BODY, AND THEN SEEDS THE VALVE. THE MOST FREQUENT CAUSES ARE DENTAL PROCEDURES, UROLOGICAL INFECTIONS AND INTERVENTIONS, AND INDWELLING CATHETERS. EDWARDS LIFESCIENCES HAS VALIDATED METHODS FOR STERILIZATION OF ALL DEVICES WHICH ENSURES PRODUCT STERILITY.
EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, IT WAS LEARNED FROM OUR IMPLANT PATIENT REGISTRY THAT THE DEVICE WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 4 MONTHS. UNFORTUNATELY, THE REASON FOR REMOVING THE VALVE WAS NOT PROVIDED. DESPITE REPEATED ATTEMPTS TO RECEIVE FURTHER INFORMATION REGARDING THE DEVICE AND EVENT, NO ADDITIONAL INFORMATION OR SAMPLE FOR EVALUATION WAS RECEIVED. ACCORDING TO OUR RECORDS, THE DEVICE WAS REPLACED WITH ANOTHER EDWARDS BIOPROSTHETIC VALVE. THERE HAVE NOT BEEN ANY ALLEGATIONS OF A PRODUCT MALFUNCTION OR DEFICIENCY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | REPLACEMENT HEART VALVE | DYE | EDWARDS LIFESCIENCES | SEE H10 | 10L257 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization| R |