FDA Adverse Event Injury Summary report: N

SENSOR UROLOGICAL GUIDEWIRE

MDR report key: 22285296 · Received June 18, 2025

Report

Report Number
2124215-2025-38165
Event Type
Injury
Date Received
June 18, 2025
Date of Event
January 1, 2013
Report Date
June 18, 2025
Manufacturer
BOSTON SCIENTIFIC CORPORATION
Product Code
EZB
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
SP
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

BLOCK B3: THE EXACT EVENT DATE IS UNKNOWN. THE PROVIDED EVENT DATE IS AN APPROXIMATE BASED ON THE RANGE THE PROCEDURES WERE PERFORMED. BLOCKS D4, H4: DETAILED PRODUCT INFORMATION WAS NOT PROVIDED TO BSC. BASED ON THE NATURE OF THE INFORMATION PROVIDED TO BSC, IT IS NOT POSSIBLE TO PERFORM A GOOD FAITH EFFORT TO OBTAIN ADDITIONAL INFORMATION. BECAUSE THE PRODUCT IS UNKNOWN AT THIS TIME, WE ARE UNABLE TO PROVIDE THE COMPLETE UNIQUE IDENTIFIER (UDI) # AND OTHER PRODUCT SPECIFIC INFORMATION. IF ADDITIONAL DETAILS BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED. BLOCK H6: PATIENT CODE E1302 CAPTURES THE REPORTABLE EVENT OF HEMATURIA. PATIENT CODE E1310 CAPTURES THE REPORTABLE EVENT OF URINARY TRACT INFECTION. PATIENT CODE E1020 CAPTURES THE REPORTABLE EVENT OF NAUSEA. PATIENT CODE E2330 CAPTURES THE REPORTABLE EVENT OF PAIN. PATIENT CODE E1032 CAPTURES THE REPORTABLE EVENT OF VOMITING. PATIENT CODE E1309 CAPTURES THE REPORTABLE EVENT OF URINARY RETENTION. IMPACT CODE F0801 CAPTURES THE REPORTABLE EVENT OF INTENSIVE CARE. LITERATURE SOURCE: PAULA GAYARRE ABRIL, BENJAMIN BLASCO BELTRAN, JORGE SUBIRA RIOS, DANIEL HIJAZO GASCON, VICTORIA CAPAPE POVES, CARLOS BLANCO CHAMORRO, MARIA RUT SIESO GRACIA, FRANCISCO XAVIER ELIZALDE BENITO, GONZALO ABRIL BAQUERO, PATRICIA CARRERA LASFUENTES, JORGE RIOJA ZUAZU. DOES TIME AND SIZE MATTER IN RETROGRADE INTRARENAL SURGERY? RESULTS ANALYSIS USING A LOW-PRESSURE TECHNIQUE. ARCH. ESP. UROL. 2023, 76(2): 107-113. HTTPS://DOI.ORG/10.56434/J.ARCH.ESP.UROL.20237602.11.

Description of Event or Problem · 0

IT WAS REPORTED TO BOSTON SCIENTIFIC VIA AN ARTICLE PUBLISHED IN THE ARCHIVOS ESPANOLES DE UROLOGIA THAT A STUDY WAS CONDUCTED THROUGH RETROGRADE INTRARENAL SURGERY AND PERCUTANEOUS NEPHROLITHOTOMY TREATMENTS AND THE ANALYSIS OF THE RESULTS FROM PATIENTS USING A LOW-PRESSURE TECHNIQUE. THIS RETROSPECTIVE STUDY ANALYZED 403 PATIENTS WHO UNDERWENT RETROGRADE INTRARENAL SURGERY (RIRS) FOR KIDNEY STONES BETWEEN 2013 AND 2019. THE AVERAGE SURGERY LASTED 111 MINUTES, AND THE AVERAGE STONE VOLUME WAS 3.5 ML. THE PROCEDURES WERE PERFORMED WITH THE PATIENT IN LITHOTOMY POSITION AND UNDER GENERAL ANESTHESIA. A SENSOR WIRE WAS INTRODUCED INTO THE RENAL CAVITIES UNDER FLUOROSCOPY. POSTOPERATIVE COMPLICATIONS INCLUDED: URINARY SYMPTOMS IN 2 PATIENTS, RENAL COLIC IN 5, PYELONEPHRITIS IN 7 CASES, 11 PATIENTS EXPERIENCED URINARY TRACT INFECTION, 1 DEVELOPED ACUTE URINARY RETENTION AND. 5 MORE PATIENTS ALSO REQUIRED INTENSIVE CARE. ADDITIONALLY, MINOR COMPLICATIONS WERE REPORTED, INCLUDING NAUSEA, VOMITING, OR PAIN.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
748283 SENSOR UROLOGICAL GUIDEWIRE STYLET FOR CATHETER, GASTRO-UROLOGY EZB BOSTON SCIENTIFIC CORPORATION

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention| O