FDA Adverse Event Injury Summary report: N

PINNACLE MTL INS NEUT36IDX54OD

MDR report key: 2213397 · Received August 12, 2011

Report

Report Number
1818910-2011-15459
Event Type
Injury
Date Received
August 12, 2011
Report Date
July 13, 2011
Manufacturer
DEPUY ORTHOPAEDICS, INC. 1818910
Product Code
KWA
PMA / PMN Number
K003523
Removal / Correction Number
NA
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CO, US
Reporter Occupation
ATTORNEY

Narratives

Additional Manufacturer Narrative · 1

THE DEVICES ASSOCIATED WITH THIS REPORT WERE NOT RETURNED. REVIEW OF THE DEVICE HISTORY RECORDS AND/OR A COMPLAINT DATABASE SEARCH WAS NOT POSSIBLE AS THE PRODUCT AND LOT CODES REQUIRED WERE NOT PROVIDED. THE INVESTIGATION COULD NOT DRAW ANY CONCLUSIONS REGARDING THE REPORTED EVENT WITH THE INFORMATION AVAILABLE. BASED ON THE INABILITY TO IDENTIFY A ROOT CAUSE, THE NEED FOR CORRECTIVE ACTION WAS NOT INDICATED. DEPUY CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD THE PRODUCT OR ADDITIONAL INFORMATION BE RECEIVED TO CHANGE THE OUTCOME OF THE PERFORMED INVESTIGATION, THE COMPLAINT WILL BE RE-OPENED

Additional Manufacturer Narrative · 1

PRODUCT COMPLAINT # (B)(4). INVESTIGATION SUMMARY: NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. THE INFORMATION RECEIVED WILL BE RETAINED FOR POTENTIAL SERIES INVESTIGATIONS IF TRIGGERED BY TREND ANALYSIS, POST MARKET SURVEILLANCE, OR OTHER EVENTS WITHIN THE QUALITY SYSTEM. DEPUY CONSIDERS THE INVESTIGATION CLOSED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED AND THE INVESTIGATION WILL BE RE-OPENED AS NECESSARY. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH , A FOLLOW-UP MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

(B)(4).

Additional Manufacturer Narrative · 1

THIS COMPLAINT IS STILL UNDER INVESTIGATION. DEPUY WILL NOTIFY THE FDA OF THE RESULTS OF THIS INVESTIGATION ONCE IT HAS BEEN COMPLETED.

Description of Event or Problem · 1

LITIGATION PAPERS ALLEGE FRICTION AND WEAR BETWEEN THE COBALT-CHROMIUM METAL HEAD AND COBALT-CHROMIUM METAL LINER CAUSED LARGE AMOUNTS OF TOXIC COBALT-CHROMIUM METAL IONS AND PARTICLES TO BE RELEASED INTO PATIENT'S BLOOD AND TISSUE AND BONE SURROUNDING THE IMPLANT. AS A RESULT, PATIENT HAS BEEN EXPERIENCING SEVERE PAIN AND DISCOMFORT AND INFLAMMATION IN HIS LEFT THIGH AND GROIN. HE ALSO EXPERIENCES A POPPING AND SNAPPING SENSATION IN HIS HIP-JOINT WHEN WALKING OR MOVING TO AND FROM A SITTING POSITION. IT IS FURTHER ALLEGED THAT DUE TO PATIENT'S CHRONIC PAIN AND DISCOMFORT AND OTHER SYMPTOMS, PATIENT WILL LIKELY NEED TO UNDERGO REVISION SURGERY TO REPLACE THE IMPLANT.

Description of Event or Problem · 1

THE UNKNOWN DEPUY PINNACLE HIP THAT WAS REPORTED IN THE WPC WAS CHANGED TO PINNACLE METAL LINER. ADDED HEAD AND STEM DUE TO A LARGE AMOUNT OF TOXIC COBALT CHROMIUM. UPDATED PATIENT DOB AND ADDED LAW FIRM IN THE FACILITY NAME.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 PINNACLE MTL INS NEUT36IDX54OD PINNACLE HIP SYSTEM : HIP METAL ACETABULAR LINERS KWA DEPUY ORTHOPAEDICS, INC. 1818910 NA 3032233

Patients

Seq Age Sex Outcome Treatment
1 NA Required Intervention