ELECSYS TROPONIN T HS
Report
- Report Number
- 1823260-2025-01595
- Event Type
- Malfunction
- Date Received
- May 23, 2025
- Date of Event
- April 28, 2025
- Report Date
- June 3, 2025
- Manufacturer
- ROCHE DIAGNOSTICS
- Product Code
- MMI
- PMA / PMN Number
- K201441
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
PATIENT 9'S INITIAL RESULT ON (B)(6) 2025 WAS 10 NG/L, THE 1ST REPEAT RESULT WAS 17 NG/L, AND THE 2ND REPEAT RESULT WAS 10NG/L. QC AND CALIBRATION WERE PASSING BEFORE THE EVENT OCCURRED, THEREFORE, A GENERAL REAGENT ISSUE IS NOT PRESENT. NO RELEVANT ALARMS WERE OBSERVED. THE INVESTIGATION WAS UNABLE TO DETERMINE A DIRECT ROOT CAUSE. THE SAMPLES ARE NOT INVERTED BEFORE CENTRIFUGATION.
THE COBAS E 801 ANALYTICAL UNIT SERIAL NUMBER IS (B)(6). THE INVESTIGATION IS ONGOING.
THERE WAS AN ALLEGATION OF QUESTIONABLE ELECSYS TROPONIN T HS RESULTS FROM THE COBAS E 801 ANALYTICAL UNIT. PATIENT 1'S INITIAL RESULT WAS 17.6 NG/L, AND THE REPEAT RESULT WAS 14.5 NG/L. PATIENT 2'S INITIAL RESULT ON (B)(6) 2025 WAS 47.7 NG/L, AND THE 1ST REPEAT RESULT WAS 39.4 NG/L, AND A 2ND REPEAT RESULT OF 39.8 NG/L. PATIENT 3'S INITIAL RESULT ON (B)(6) 2025 WAS 102 NG/L, AND THE 1ST REPEAT RESULT WAS 54.9 NG/L, AND A 2ND REPEAT RESULT OF 55.0 NG/L. PATIENT 4'S INITIAL RESULT ON (B)(6) 2025 WAS 20.4 NG/L, AND THE 1ST REPEAT RESULT WAS 14.2 NG/L. WHEN REPEATED ON A SECOND ANALYZER, THE RESULT WAS 13.8 NG/L. PATIENT 5'S INITIAL RESULT ON (B)(6) 2025 WAS 26.3 NG/L, AND THE 1ST REPEAT RESULT WAS 19.3 NG/L, AND A 2ND REPEAT RESULT OF 20 NG/L. PATIENT 6'S INITIAL RESULT ON (B)(6) 2025 WAS 4542 NG/L. THE 1ST REPEAT RESULT WAS 5975 NG/L. THE 2ND REPEAT RESULT WAS 6244 NG/L. THE 3RD REPEAT RESULT WAS 6297 NG/L. PATIENT 7'S INITIAL RESULT ON (B)(6) 2025 WAS 3.69 NG/L. THE 1ST REPEAT RESULT WAS 5.08 NG/L. THE 2ND REPEAT RESULT WAS 11.5 NG/L. THE 3RD REPEAT RESULT WAS 3.95 NG/L. PATIENT 8'S INITIAL RESULT ON (B)(6) 2025 WAS 17.6 NG/L. THE 1ST REPEAT RESULT WAS 26.3 NG/L. THE 2ND REPEAT RESULT WAS 30.6 NG/L. THE 3RD REPEAT RESULT WAS 18 NG/L. THE 4TH REPEAT RESULT WAS 19.2 NG/L.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 818596 | ELECSYS TROPONIN T HS | IMMUNOASSAY METHOD, TROPONIN SUBUNIT | MMI | ROCHE DIAGNOSTICS | 811848 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |