B3 DATE OF EVENT: ESTIMATED AS 03/28/2025 AS THE ONLINE PUBLISHED DATE FOR THE ARTICLE IS NOTED AS MARCH 28, 2025. CITATION: HIGGINS, A, ZIMMERMAN, S, WANG, Y. ET AL. LONG-TERM OUTCOMES FOLLOWING LEFT ATRIAL APPENDAGE OCCLUSION IN MEDICARE BENEFICIARIES: OUTCOMES FROM THE NATIONAL CARDIOVASCULAR DATA REGISTRY. JACC. 2025 APR, 85 (12_SUPPLEMENT) 869. HTTPS://DOI.ORG/10.1016/S0735-1097(25)01353-1.
REPORTED VIA LITERATURE ARTICLE: IT WAS REPORTED STROKE(S) OCCURRED. THE NATIONAL CARDIOVASCULAR DATA REGISTRY LEFT ATRIAL APPENDAGE OCCLUSION (LAAO) REGISTRY DATA WAS USED FOR INPATIENT MEDICARE CLAIMS DATA USING DETERMINISTIC MATCHING AND ESTABLISHED A COHORT OF PATIENTS >/=65 YEARS OF AGE WHO UNDERWENT LAAO BETWEEN JANUARY 2016 AND DECEMBER 2019. EVENT FREE SURVIVAL WAS CALCULATED USING THE KAPLAN-MEIER METHOD FOR DEATH AND THE CUMULATIVE INCIDENCE FUNCTION, ACCOUNTING FOR COMPETING RISK OF DEATH, FOR STROKE. RESULTS: A TOTAL OF 34,975 PATIENTS WITH AN AVERAGE AGE 77.5 YEARS (SD 6.5) AND 41.8% FEMALE WERE INCLUDED. THE AVERAGE CHA(2) DS(2)-VASC SCORE WAS 4.7 (SD 1.4). MEDIAN FOLLOW-UP WAS 2.8 YEARS (IQR 2.2-3.7 YEARS). THE INCIDENCE OF ANY STROKE AND ISCHEMIC STROKE WERE 1.80 (95% CI 1.66-94) AND 1.47 (95% CI 1.35-1.59) PER 100 PERSON-YEAR, RESPECTIVELY. THE FIVE-YEAR RATES OF ANY STROKE AND ISCHEMIC STROKE WERE 5.70% (95% CI 5.37-6.05) AND 5.03% (95% CI 4.71-5.36%), RESPECTIVELY. THE INCIDENCE OF DEATH WAS 10.37 (10.05-10.68) PER 100 PERSON-YEARS AND THE FIVE-YEAR MORTALITY RATE WAS 44.34% (95% CI 43.45-45.23%). CONCLUSION: LONG-TERM ISCHEMIC STROKE RATES IN A LARGE NATIONALLY REPRESENTATIVE COHORT OF MEDICARE PATIENTS FOLLOWING WATCHMAN LAAO WERE LOW DESPITE A HIGH EMBOLIC RISK. CITATION: HIGGINS, A, ZIMMERMAN, S, WANG, Y. ET AL. LONG-TERM OUTCOMES FOLLOWING LEFT ATRIAL APPENDAGE OCCLUSION IN MEDICARE BENEFICIARIES: OUTCOMES FROM THE NATIONAL CARDIOVASCULAR DATA REGISTRY. JACC. 2025 APR, 85 (12_SUPPLEMENT) 869. HTTPS://DOI.ORG/10.1016/S0735-1097(25)01353-1.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 937406 | WATCHMAN LAA CLOSURE DEVICE & DELIVERY SYSTEM | SYSTEM, APPENDAGE CLOSURE, LEFT ATRIAL | NGV | BOSTON SCIENTIFIC CORPORATION |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Other |