FDA Adverse Event Injury Summary report: N

SHOULDER SYSTEM

MDR report key: 22060633 · Received May 21, 2025

Report

Report Number
3005180920-2025-00472
Event Type
Injury
Date Received
May 21, 2025
Date of Event
May 1, 2025
Report Date
May 19, 2025
Manufacturer
MEDACTA INTERNATIONAL SA
Product Code
PHX
UDI-DI
07630040706179
PMA / PMN Number
K170452
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MO, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

BATCH REVIEW PERFORMED ON 8 MAY 2025. (B)(4) ITEMS MANUFACTURED AND RELEASED ON 31/01/2024. EXPIRATION DATE: 15/01/2029. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, ALL ITEMS OF THE SAME LOT HAVE BEEN SOLD WITH NO SIMILAR REPORTED EVENT DURING THE PERIOD OF REVIEW. ADDITIONAL DEVICES INVOLVED: REVERSE SHOULDER SYSTEM 04.01.0119 HUMERAL REVERSE HC LINER Ø36/+0MM (K170452) LOT. 2314461 (B)(4) ITEMS MANUFACTURED AND RELEASED ON 08/08/2023. EXPIRATION DATE: 22/07/2028. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, ALL ITEMS OF THE SAME LOT HAVE BEEN SOLD WITH ONE SIMILAR REPORTED EVENT DURING THE PERIOD OF REVIEW. REVERSE SHOULDER SYSTEM 04.01.0191 THREADED GLENOID BASEPLATE Ø24.5X30 (K171058) LOT. 2242354 (B)(4) ITEMS MANUFACTURED AND RELEASED ON 07/03/2023. EXPIRATION DATE: 19/02/2028. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITH NO SIMILAR REPORTED EVENT DURING THE PERIOD OF REVIEW. REVERSE SHOULDER SYSTEM 04.01.0207 LAT. GLENOSPHERE 36XØ24.5 (K193175) LOT. 2315418 (B)(4) ITEMS MANUFACTURED AND RELEASED ON 08/11/2023. EXPIRATION DATE: 15/10/2028. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN SOLD WITH NO SIMILAR REPORTED EVENT DURING THE PERIOD OF REVIEW. ROOT CAUSE: INFECTION IS A KNOWN POSSIBLE COMPLICATION OF ANY SURGERY. ALTHOUGH NO ROOT CAUSE CAN BE ESTABLISHED, THERE IS NO INDICATION THAT ANY ISSUE WITH THE DEVICE MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT, AND THE DOCUMENT REVIEW DOES NOT INDICATE ANY POTENTIAL MANUFACTURING RELATED CAUSE.

Description of Event or Problem · 0

THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. ABOUT 1 YEAR AND 1 MONTH AFTER THE PRIMARY SURGERY, THE SURGEON REVISED ALL MEDACTA HARDWARE AND REIMPLANTED COMPETITOR COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
645172 SHOULDER SYSTEM HUMERAL REVERSE METAPHYSIS +0MM/0° PHX MEDACTA INTERNATIONAL SA 04.01.0110 2335874A 07630040706179

Patients

Seq Age Sex Outcome Treatment
1 74 YR Female Required Intervention