INVOS
Report
- Report Number
- 2936999-2025-00256
- Event Type
- Malfunction
- Date Received
- May 21, 2025
- Date of Event
- September 1, 2023
- Report Date
- May 21, 2025
- Manufacturer
- JIANGYIN SINBON ELECTRONICS CO LTD
- Product Code
- MUD
- UDI-DI
- 10884521780125
- PMA / PMN Number
- K182868
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CO, US
- Reporter Occupation
- 003
Narratives
D10 CONCOMITANT PRODUCT: PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20); PMAC71RSC, SENSOR CABLE RE-USABLE PMAC71RSC INVOS (LOT#2023-07-20) H3 EVALUATION SUMMARY: MEDTRONIC CONDUCTED AN INVESTIGATION BASED UPON ALL INFORMATION RECEIVED. THE DEVICE WAS AVAILABLE FOR EVALUATION. VISUAL INSPECTION NOTED THAT THE CABLE OF THE UNIT WAS DEFECTIVE. IT WAS REPORTED THAT THE CABLE WAS DEFECTIVE, THE PRODUCT WAS DEFECTIVE UPON RECEIPT AND THE SENSOR WAS NOT RECOGNIZED BY THE MONITOR. THE REPORTED ISSUES WERE CONFIRMED. THE MOST LIKELY CAUSE WAS TRACED TO COMPONENT FAILURE. A REVIEW OF THE DEVICE HISTORY RECORDS FOUND POTENTIALLY CONTRIBUTING FACTORS FROM THE MANUFACTURING PROCESS. THIS REPORT IS BEING SUBMITTED AS PART OF REMEDIATION ACTIVITIES ASSOCIATED WITH CAPA # 643143, WHICH IS ADDRESSING MDR REPORTING GUIDANCE FROM FDAS 1995 PREAMBLE, WHICH ENSURES COMPLAINTS RELATED TO CORRECTIONS AND RECALLS WHICH WERE PREVIOUSLY REPORTED TO FDA UNDER 21 CFR 806 ARE NOW REPORTED AS MDRS ; THIS IS NOT A NEW MALFUNCTION/EVENT. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
ACCORDING TO THE REPORTER, PRIOR TO USE, THE CABLE WAS TESTED WITH FILED TEST DEVICE, WITH SENSOR OR WITH BOTH AND NO SENSOR WAS DETECTED. IT WAS A FAILURE OUT OF BOX. THERE WAS NO PATIENT INVOLVEMENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 761358 | INVOS | OXIMETER, TISSUE SATURATION | MUD | JIANGYIN SINBON ELECTRONICS CO LTD | PMAC71RSC | 2023-07-20 | 10884521780125 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |