FDA Adverse Event Injury Summary report: N

HOMECHOICE AUTOMATED PD SET WITH CASSETTE

MDR report key: 2200236 · Received August 11, 2011

Report

Report Number
1423500-2011-10526
Event Type
Injury
Date Received
August 11, 2011
Date of Event
July 1, 2011
Report Date
July 29, 2011
Manufacturer
BAXTER HEALTHCARE - MOUNTAIN HOME
Product Code
FKX
PMA / PMN Number
K923065
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CO, US
Reporter Occupation
NURSE

Narratives

Additional Manufacturer Narrative · 1

(B)(4). AS THE DATE OF ONSET OF THIS PERITONITIS EPISODE IS UNKNOWN AND PATIENTS DISCARD SUPPLIES AFTER EACH THERAPY, THE SAMPLE WAS NOT REQUESTED. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, A FOLLOW-UP REPORT WILL BE SUBMITTED. THIS IS REPORT 1 OF 5 INVOLVED IN THIS PERITONITIS EVENT.

Additional Manufacturer Narrative · 1

(B)(4). A BATCH REVIEW WAS PERFORMED FOR POTENTIALLY ASSOCIATED LOT NUMBERS H11B24102, H11C25115, H11D18043, AND H11A31034 WITH NO DEFECTS NOTED. THE CAUSE OF THE PERITONITIS WAS UNDETERMINED. BAXTER HAS RECEIVED SIMILAR REPORTS FOR THE REPORTED PROBLEM. THE ROOT CAUSE INVESTIGATION IS IN PROGRESS THROUGH CAPA (B)(4).

Description of Event or Problem · 1

INITIALLY, THE PATIENT CALLED THE BAXTER TECHNICAL SERVICE REPRESENTATIVE (TSR) REGARDING A CHECK SUPPLY LINE ALARM, WHICH OCCURRED ON THE HOMECHOICE (HC), DURING PRIME. THE TSR ASSISTED THE HP TO COMPLETE THE PRIME. THE SOLUTION WAS PROVIDED OVER THE PHONE AND THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION INDICATED AT THE TIME OF THE INITIAL CALL. ON (B)(6) 2011, DURING A FOLLOW UP CALL WITH THE PATIENT BY BAXTER PRODUCT SURVEILLANCE REGARDING THE CHECK SUPPLY LINE ALARM, THE PATIENT STATED THE SAMPLE HAD BEEN DISCARDED AND THERE WAS NO LOT NUMBER AVAILABLE. DURING THE CONVERSATION, THE HP SAID THE NEXT DAY AFTER THE INCIDENT WITH THE ALARM, HE WENT TO HIS CLINIC AND HE WAS DIAGNOSED WITH PERITONITIS. THE HP SAID HE WAS GIVEN ANTIBIOTICS AND THAT HE IS FEELING BETTER. NO FURTHER INFORMATION WAS PROVIDED BY THE CONSUMER ON THE INITIAL FOLLOW UP CALL. ON (B)(6) 2011, PRODUCT SURVEILLANCE FOLLOWED UP WITH THE PATIENT'S PERITONEAL DIALYSIS NURSE (PDN) WHO PROVIDED THE FOLLOWING INFORMATION. THE PDN CONFIRMED THAT THE PATIENT WAS DIAGNOSED WITH PERITONITIS COINCIDENT WITH 2.5 % DIANEAL AMBUFLEX AND ICODEXTRIN THERAPY (DOSES, FREQUENCIES AND LOTS WERE NOT REPORTED). THE PATIENT WAS NOT HOSPITALIZED AND RECEIVED REMEDIAL TREATMENT WITH AN UNSPECIFIED ANTIBIOTIC. ON AN UNSPECIFIED DATE, THE PATIENT RECOVERED FROM THE PERITONITIS. CONCOMITANT MEDICATIONS WERE NOT REPORTED. THE PDN STATED THE PATIENT IS USING UNSPECIFIED DISPOSABLE PRODUCTS WITH LUER CONNECTORS. THE PDN STATED THAT THE PATIENT WAS EXPERIENCING DIARRHEA AT THE TIME THAT THE PERITONITIS OCCURRED. THE PDN STATED THE CAUSE OF THE PERITONITIS WAS UNKNOWN, HOWEVER, COULD BE INTERNAL. THE PDN DID NOT CONSIDER THE PERITONITIS TO BE RELATED TO THE PD THERAPY AND NOT RELATED TO ANY BAXTER PRODUCT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 HOMECHOICE AUTOMATED PD SET WITH CASSETTE SYSTEM, PERITONEAL, AUTOMATIC DELIVERY FKX BAXTER HEALTHCARE - MOUNTAIN HOME

Patients

Seq Age Sex Outcome Treatment
1 52 YR Required Intervention ICODEXTRIN| 2.5 % DIANEAL AMBUFLEX