TECNIS SIMPLICITY
Report
- Report Number
- 3012236936-2025-000128
- Event Type
- Injury
- Date Received
- May 8, 2025
- Report Date
- May 8, 2025
- Manufacturer
- AMO PUERTO RICO MFG. INC.
- Product Code
- HQL
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
SECTION A2 - AGE: THE MEAN AGE IS 73.34 ± 10.75 YEARS. SECTION A3A - SEX: PERCENTAGE OF MEN 45.7% (16 OF 35) AND WOMEN BEING 54.3% (19 OF 35). SECTIONS A3B, A4 AND A5: INFORMATION UNKNOWN/NOT PROVIDED. SECTION B3 - DATE OF EVENT: EXACT DATE NOT PROVIDED. ARTICLE ACCEPTANCE DATE IS MAY 21, 2024. SECTION D4 - CATALOG NUMBER: A COMPLETE NUMBER IS UNKNOWN, AS PRODUCT SERIAL NUMBER WAS NOT PROVIDED. SECTION D4 - SERIAL NUMBER: UNKNOWN/NOT PROVIDED. SECTION D4 - EXPIRATION DATE: UNKNOWN, AS PRODUCT SERIAL NUMBER WAS NOT PROVIDED. SECTION D4 - UDI NUMBER: UNKNOWN, AS PRODUCT SERIAL NUMBER WAS NOT PROVIDED. SECTION D6A - IMPLANT DATE: INFORMATION UNKNOWN/NOT PROVIDED. SECTION D6B - EXPLANT DATE: NOT APPLICABLE, AS LENS REMAINS IMPLANTED. SECTION G4 - PMA/510(K) #: THIS REPORT IS BEING FILED ON AN INTERNATIONAL DEVICE; TECNIS OPTIBLUE SIMPLICITY PRELOADED 1-PIECE IOL, MODEL DCB00V THAT HAS A SIMILAR DEVICE, TECNIS SIMPLICITY PRELOADED 1-PIECE IOL MODEL DCB00 WHICH IS DISTRIBUTED IN THE UNITED STATES UNDER PMA P980040. SECTION H3: THE INTRAOCULAR LENS WAS NOT RETURNED FOR ANALYSIS. THE SERIAL NUMBER FOR THIS DEVICE IS NOT AVAILABLE; THEREFORE, NO FURTHER INVESTIGATION CAN BE PERFORMED. IF THERE IS ANY FURTHER RELEVANT INFORMATION RECEIVED, A SUPPLEMENTAL MEDWATCH WILL BE FILED. SECTION H6 - HEALTH EFFECT - CLINICAL CODE: 4581: NO CODE AVAILABLE (DEVICE DISLOCATION) CITATION: KOMATSU, K., MASUDA, Y., TACHIBANA, S., SANO, K., IIDA, M., ICHIHARA, K., OKI, T., FUKAI, K., TATEMICHI, M., & NAKANO, T. (2024). POSTOPERATIVE VISUAL FUNCTION OF EXTENDED DEPTH-OF-FOCUS INTRAOCULAR LENSES VERSUS MONOFOCAL LENSES. JOURNAL OF REFRACTIVE SURGERY (THOROFARE, N.J. : 1995), 40(7), E499¿E505. HTTPS://DOI.ORG/10.3928/1081597X-20240522-01 ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.
THE FOLLOWING ARTICLE WAS RECEIVED BASED ON A LITERATURE REVIEW: ARTICLE: POSTOPERATIVE VISUAL FUNCTION OF EXTENDED DEPTH-OF-FOCUS INTRAOCULAR LENSES VERSUS MONOFOCAL LENSES POSTOPERATIVE VISUAL FUNCTION OF EXTENDED DEPTH-OF-FOCUS INTRAOCULAR LENSES VERSUS MONOFOCAL LENSES A RETROSPECTIVE OBSERVATIONAL STUDY WAS DONE TO ASSESS THE EFFECTS OF INTRAOCULAR LENS (IOL) DECENTRATION AND TILT, AS WELL AS AGE, ON POSTOPERATIVE VISUAL FUNCTION (CORRECTED DISTANCE VISUAL ACUITY [CDVA] AND CONTRAST SENSITIVITY) BY COMPARING AN EXTENDED DEPTH-OF-FOCUS IOL USING HIGHER ORDER ASPHERIC OPTICS AGAINST A MONOFOCAL IOL FROM THE SAME PLATFORM. PHACOEMULSIFICATION WAS CONDUCTED USING A PHACOEMULSIFICATION MACHINE (CENTURION, ALCON LABORATORIES, INC OR WHITESTAR SIGNATURE PRO, AMO, INC). AN IOL WAS INSERTED INTO THE CAPSULAR BAG. A TOTAL OF 69 PATIENTS (N=96 EYES) WERE INCLUDED AND DIVIDED INTO: TECNIS EYHANCE OPTIBLUE GROUP (N=61 EYES) WHO HAD DIB00V/DIW LENSES IMPLANTED, AND TECNIS OPTIBLUE 1-PIECE GROUP (N=35 EYES) WHO HAD DCB00V LENSES IMPLANTED. HIGHER ORDER ABERRATIONS (HOAS, M): TECNIS EYHANCE OPTIBLUE = 0.23 ± 0.07; TECNIS OPTIBLUE 1-PIECE = 0.24 ± 0.08 IOL TILT (°): TECNIS EYHANCE OPTIBLUE = 4.79 ± 1.5; TECNIS OPTIBLUE 1-PIECE = 4.73 ± 1.31 IOL DECENTRATION (MM): TECNIS EYHANCE OPTIBLUE = 0.18 ± 0.09; TECNIS OPTIBLUE 1-PIECE = 0.17 ± 0.1 WITHIN 3 MONTHS POSTOPERATIVE: PHOTOPIC CONTRAST SENSITIVITY (CS) AREA UNDER LOG CONTRAST SENSITIVITY FUNCTION (AULCSF): TECNIS EYHANCE OPTIBLUE = 1.58 ± 0.13; TECNIS OPTIBLUE 1-PIECE = 1.46 ± 0.18 SCOTOPIC CS (AULCSF): TECNIS EYHANCE OPTIBLUE =1.71 ± 0.11; TECNIS OPTIBLUE 1-PIECE = 1.59 ± 0.19 OTHER J&J PRODUCTS WERE MENTIONED BUT NO COMPLAINTS WERE REPORTED AGAINST THEM. THERE WERE NO FURTHER INTERVENTIONS REPORTED. NOTE: SEPARATE REPORTS WILL BE SUBMITTED FOR THE OTHER REPORTED LENS MODELS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 847498 | TECNIS SIMPLICITY | INTRAOCULAR LENS | HQL | AMO PUERTO RICO MFG. INC. | DCB00V |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Other |