MEDTRONIC TRANSCATHETER VALVE
Report
- Report Number
- 2025587-2025-03352
- Event Type
- Injury
- Date Received
- May 2, 2025
- Date of Event
- January 7, 2025
- Report Date
- May 2, 2025
- Manufacturer
- MEDTRONIC HEART VALVES DIVISION
- Product Code
- NPT
- PMA / PMN Number
- P130021
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- PA, US
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
CITATION: YAMASHITA ET AL. TRANSCATHETER AORTIC VALVE-IN-VALVE IMPLANTATION WITH NEWER GENERATION EVOLUT VALVE BY SIZE OF FAILED BIO PROSTHESIS. ANATOL J CARDIOL. JAN 7;29(3):118-123. 2025. 10.14744/ANATOLJCARDIOL.2024.4633. EARLIEST DATE OF PUBLICATION USED FOR DATE OF EVENT. NO UNIQUE DEVICE IDENTIFIER (SERIAL/LOT) NUMBERS WERE PROVIDED; WITHOUT THIS INFORMATION IT COULD NOT BE DETERMINED WHETHER THESE OBSERVATIONS HAVE BEEN PREVIOUSLY REPORTED. WITHOUT RETURN OF THE PRODUCT NO DEFINITIVE CONCLUSION CAN BE MADE REGARDING THE CLINICAL OBSERVATIONS. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
LITERATURE WAS REVIEWED REGARDING TRANSCATHETER AORTIC VALVE-IN-VALVE IMPLANTATION WITH NEWER GENERATION EVOLUT BIOPROSTHETIC VALVE BY SIZE OF DECOMPENSATED BIOPROSTHESIS. THE STUDY POPULATION INCLUDED 91 PATIENTS WHO WERE PREDOMINANTLY MALE WITH A MEDIAN AGE OF 78 YEARS OLD. ALL PATIENTS WERE IMPLANTED WITH A MEDTRONIC EVOLUT PRO OR EVOLUT PRO+ OR EVOLUT FX BIOPROSTHETIC VALVE. DEATHS OCCURRED IN THE STUDY POPULATION; HOWEVER, THERE WAS NO STATEMENT ESTABLISHING A CAUSAL OR CONTRIBUTORY RELATIONSHIP BETWEEN MEDTRONIC PRODUCT AND THE DEATHS. AMONG ALL PATIENTS, CLINICAL OBSERVATIONS INCLUDED: CORONARY OCCLUSION, STROKE, ARRHYTHMIA REQUIRING PERMANENT PACEMAKER IMPLANT, HIGH GRADIENTS OVER 20 MMHG, PATIENT-PROSTHESIS MISMATCH, MODERATE AORTIC REGURGITATION, MYOCARDIAL INFARCTION, BIOPROSTHETIC VALVE DETERIORATION, AND CONGESTIVE HEART FAILURE REQUIRING HOSPITALIZATION. NO FURTHER INFORMATION WAS PROVIDED PERTAINING TO MEDTRONIC PRODUCTS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1656396 | MEDTRONIC TRANSCATHETER VALVE | AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIV | NPT | MEDTRONIC HEART VALVES DIVISION | MDT-TRANS VALVE |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 78 YR | Male | Required Intervention| L| H |