TECNIS IOL
Report
- Report Number
- 3012236936-2025-000122
- Event Type
- Injury
- Date Received
- April 30, 2025
- Report Date
- April 30, 2025
- Manufacturer
- AMO PUERTO RICO MFG. INC.
- Product Code
- POE
- PMA / PMN Number
- P980040
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
SECTION A2: AGE/DATE OF BIRTH (MONTHS): AGES ARE 65.6 ± 8.8. SECTION A3: SEX/GENDER: (MALE: FEMALE): 20:24. SECTION A4 & A5: INFORMATION UNKNOWN, NOT PROVIDED. SECTION B3: DATE OF EVENT: EXACT DATES NOT PROVIDED, ARTICLE ACCEPTANCE DATE IS 18 JANUARY 2024. SECTION D4: MODEL NUMBER: UNKNOWN, INFORMATION NOT PROVIDED. SECTION D4: A COMPLETE CATALOG NUMBER IS UNKNOWN AS THE SERIAL NUMBER WAS NOT PROVIDED. SECTION D4: SERIAL NUMBER: UNKNOWN, INFORMATION NOT PROVIDED. SECTION D4: EXPIRATION DATE: UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. SECTION D4: UDI NUMBER: A COMPLETE UDI NUMBER IS UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. SECTION D6A: IMPLANT DATE: UNKNOWN, INFORMATION NOT PROVIDED. SECTION D6B: EXPLANT DATE: NOT APPLICABLE, AS LENS WAS NOT EXPLANTED. SECTION H3- THE DEVICE WAS NOT RETURNED FOR ANALYSIS. THE SERIAL LOT/SERIAL NUMBER FOR THIS DEVICE IS NOT AVAILABLE; THEREFORE, NO FURTHER INVESTIGATION CAN BE PERFORMED. IF THERE IS ANY FURTHER RELEVANT INFORMATION RECEIVED, A SUPPLEMENTAL MEDWATCH WILL BE FILED. SECTION H4: DEVICE MANUFACTURE DATE: UNKNOWN, AS THE SERIAL NUMBER WAS NOT PROVIDED. CITATION: CITATION: DA RAN KIM, YOUNG CHAE YOON, WOONG-JOO WHANG, HO SIK HWANG AND KYUNG-SUN NA, OCULAR PARAMETERS ASSOCIATED WITH VISUAL PERFORMANCE OF ENHANCED MONOFOCAL INTRAOCULAR LENS, (2024), BMC OPHTHALMOLOGY; 24 : 74. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.
LITERATURE TITLE: OCULAR PARAMETERS ASSOCIATED WITH VISUAL PERFORMANCE OF ENHANCED MONOFOCAL INTRAOCULAR LENS. A RETROSPECTIVE STUDY WAS DONE TO FIND OUT WHICH OCULAR PARAMETERS AFFECT VISION PERFORMANCE AND PHOTIC PHENOMENON OF TECNIS EYHANCE ICB00 OR TECNIS EYHANCE TORIC DIU AT DIFFERENT DISTANCES. A TOTAL OF 58 EYES OF 43 PATIENTS UNDERWENT CATARACT SURGERY AND WERE IMPLANTED WITH EITHER THE TECNIS EYHANCE ICB00 (N=37 EYES OF 28 PATIENTS) OR TECNIS EYHANCE TORIC DIU (N=21 EYES OF 16 PATIENTS) IOLS. AT 1-MONTH POST-OP, IT WAS REPORTED THAT THE POSTOPERATIVE AVERAGE VALUE OF THE INTRAOCULER LENS (IOL) DECENTRATION AMOUNT WAS 0.25 ± 0.17 MM (RANGE 0.04, 0.63 MM, MEDIAN 0.22 MM). THE SPHERICAL ABERRATION (MICROM), VERTICAL COMA (ROOT MEAN SQUARE, MICROM), AND HORIZONTAL COMA (ROOT MEAN SQUARE, MICROM) VALUES WERE REPORTED AS FOLLOWS: SPHERICAL ABERRATION (MICROM): NEAR: -0.517. INTERMEDIATE: -0.239. DISTANCE: 0.194. VERTICAL COMA (ROOT MEAN SQUARE, MICROM): NEAR: 0.031. INTERMEDIATE: -0.115. DISTANCE: 0.156. HORIZONTAL COMA (ROOT MEAN SQUARE, MICROM): NEAR: -0.146. INTERMEDIATE: -0.194. DISTANCE: 0.151. ADDITIONALLY, IT WAS REPORTED THAT DEEPER ANTERIOR CHAMBER DEPTH (ACD) WAS ASSOCIATED WITH POORER TOTAL QUALITY OF VISION (QOV), PARTICULARLY IN GLARE, HALO, BLUR, AND FLUCTUATION PERCEPTION. (COUNTS / AVERAGES / PERCENTAGES OF ADVERSE EVENTS WERE NOT REPORTED) THERE WERE NO CLEAR DISTINCTION ON WHICH VALUES WERE ATTRIBUTED TO WHICH DEVICE. A COPY OF THE ARTICLE IS PROVIDED WITH THIS REPORT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2356609 | TECNIS IOL | EXTENDED DEPTH OF FOCUS INTRAOCULAR LENS | POE | AMO PUERTO RICO MFG. INC. | ICB00 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |