PUMP IN STYLE BREAST PUMP
Report
- Report Number
- 1419937-2011-00152
- Event Type
- Malfunction
- Date Received
- July 21, 2011
- Date of Event
- June 22, 2011
- Report Date
- June 23, 2011
- Manufacturer
- MEDELA, INC.
- Product Code
- HGX
- PMA / PMN Number
- K031614
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SC, US
- Reporter Occupation
- NOT APPLICABLE
Narratives
A REPLACEMENT POWER ADAPTER WAS SENT TO THE CUSTOMER. IN FOLLOW UP WITH THE CUSTOMER, SHE INDICATED THAT THERE WAS A FIRE "HALFWAY BETWEEN THE PLUG THAT GOES INTO THE PUMP AND THE OUTLET CONNECTOR, BUT IT DID NOT GET TO FULL FLAMES. IT WAS BRIGHT ORANGE/YELLOW LIKE RIGHT BEFORE IT FLAMES UP" AND THERE WAS MELTING AT THE SITE WHERE IT CAUGHT FIRE ALONG WITH A CRACK, BUT NOT THAT SHE HAD NOTICED PRIOR TO THE INCIDENT. SHE ALSO INDICATED THAT SHE DID WRAP THE CORD AROUND THE TRANSFORMER HOUSING, THAT HER REPLACEMENT POWER SUPPLY IS WORKING W/O ISSUE AND THAT NO INJURIES WERE SUSTAINED AS A RESULT OF THE ISSUE. IN SUMMARY, A BREACH IN THE INSULATION ON THE DC OUTPUT CORD WAS PRESENT, EXPOSING WIRES AND RESULTING IN A SHORT WHICH COULD CAUSE A FIRE. AS A RESULT OF (B)(4) WHICH WAS INITIATED FOR PUMP IN STYLE TRANSFORMER OVERHEATING/MELTING ISSUES, A FIELD ACTION SAFETY NOTIFICATION WAS INITIATED ON 04/04/2011. ACTIVITIES RELATED TO THIS NOTIFICATION ARE ON-GOING. EVALUATION SUMMARY: A VISUAL EXAMINATION OF THE POWER SUPPLY REVEALED NO DEFORMATION ON THE TRANSFORMER HOUSING AND NO HOLES OR OPENINGS. A VISUAL EXAMINATION OF THE CORD REVEALED TWISTING AND KINKING AND A BREACH IN THE INSULATION ALONG THE LENGTH OF THE CORD. THE POWER SUPPLY WAS PLUGGED IN AND THE VOLTAGE ACROSS THE DC PLUG WAS MEASURED AT 12.7 VDC, WHICH IS NORMAL AND INDICATES THAT THE POWER SUPPLY IS PRODUCING THE CORRECT VOLTAGE. RESISTANCE ACROSS THE DC PLUG WAS MEASURED AT 0.76 OHMS, WHICH INDICATES THAT THERE IS A SHORT IN THE DC CORD. SMOKE, FIRE AND SPARKING WERE NOT OBSERVED WHILE THE POWER SUPPLY WAS PLUGGED IN. THE RESISTANCE ACROSS THE AC BLADES MEASURED AT 58.5 OHMS, WHICH IS NORMAL AND INDICATES THAT THE THERMAL FUSE DID NOT BLOW.
THE CUSTOMER REPORTED TO CUSTOMER SERVICE THAT THE POWER SUPPLY FOR HER BREAST PUMP "ACTUALLY CAUGHT ON FIRE." SHE PLUGGED IT IN BUT THE PUMP WOULD NOT PRODUCE SUCTION SO SHE CHECKED THE POWER SUPPLY AND SAW SMOKE. WHEN SHE UNPLUGGED IT SHE FOUND A BREAK IN THE CORD CONNECTION AND ACTUALLY SAW FLAMES COMING FROM THE BOX. THE CORD IS MELTED. NO INJURIES WERE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | PUMP IN STYLE BREAST PUMP | HGX | MEDELA, INC. | 57063 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |