CYPHER SIROLIMUS-ELUTING CORONARY STENT
Report
- Report Number
- 9616099-2011-00578
- Event Type
- Injury
- Date Received
- August 5, 2011
- Date of Event
- May 31, 2011
- Report Date
- September 6, 2011
- Manufacturer
- CORDIS DE MEXICO
- Product Code
- NIQ
- PMA / PMN Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- OTHER
Narratives
PER THE ARTICLE PUBLISHED IN THE CIRCULATION JOURNAL OFFICIAL JOURNAL OF THE JAPANESE CIRCULATION SOCIETY "IMPACT OF HINGE MOTION ON IN-STENT RESTENOSIS AFTER SIROLIMUS-ELUTING STENT IMPLANTATION," YASUSHI INO, MD; TAKASHI KUBO, MD, PHD; HIRONORI KITABATA, MD, PHD; KUNIHIRO SHIMAMURA, MD; YASUTSUGU SHIONO, MD; MAKOTO ORII, MD; KEISHI OKOCHI, MD; HIROMICHI SOUGAWA, MD; TAKASHI TANIMOTO, MD, PHD; KENICHI KOMUKAI, MD; KOHEI ISHIBASHI, MD; SHIGEHO TAKARADA, MD, PHD; HIROKO NAKANISHI, MD; ATSUSHI TANAKA, MD, PHD; KEIZO KIMURA, MD, PHD; KUMIKO HIRATA, MD, PHD; MASATO MIZUKOSHI, MD, PHD; TOSHIO IMANISHI, MD, PHD; TAKASHI AKASAKA, MD, PHD. ALL PATIENTS WERE INCLUDED IN THE STUDY BETWEEN 2004 AND 2007. THIS PATIENT HAD ONE 2.5 X 18MM CYPHER STENT IMPLANTED TO TREAT SEVERE STENOSIS OF THE LEFT CIRCUMFLEX ARTERY. THE TARGET LESION HAD A HINGE MOTION WITH 47 DEGREE ANGULATION. AT THE 9 MONTH FOLLOW-UP SEVERE IN-STENT RESTENOSIS WAS NOTED AT THE DISTAL EDGE OF THE STENT. THE HINGE POINT HAD SHIFTED TO THE DISTAL EDGE OF THE STENT. BACKGROUND: A TORTUOUS LESION WITH HINGE MOTION IS REPORTEDLY A RISK FACTOR FOR IN-STENT RESTENOSIS (ISR) AFTER BARE METAL STENT IMPLANTATION. SIROLIMUS-ELUTING STENTS (SESS) IMPLANTATION HAS DRAMATICALLY REDUCED ISR. HOWEVER, SES IS A CLOSED-CELL DESIGN STENT, WHICH HAS LOW CONFORMABILITY AND FLEXIBILITY. SEVERAL STUDIES HAVE REPORTED A RELATIONSHIP BETWEEN TORTUOUS LESIONS AND STENT FRACTURE, WHICH IS ONE OF THE CAUSES OF ISR. THE EFFICACY OF SES IN A TORTUOUS LESION WITH HINGE MOTION HAS NOT BEEN FULLY EVALUATED. THE AIM OF THIS STUDY WAS TO INVESTIGATE THE RELATIONSHIP BETWEEN TORTUOUS LESIONS AND ISR AFTER SES IMPLANTATION. METHODS AND RESULTS: THREE YEAR CLINICAL FOLLOW-UP DATA AFTER SES IMPLANTATION, INCLUDING 6-9 MONTH SCHEDULED FOLLOW-UP CORONARY ANGIOGRAPHY IN 399 CONSECUTIVE PATIENTS WITH 537 LESIONS, WERE OBTAINED. ANGLE WAS DEFINED AS THE DIFFERENCE IN THE ANGLE OF THE TARGET LESION BETWEEN THE DIASTOLE AND SYSTOLE BEFORE THE PROCEDURE. THE INCIDENCE OF ISR WAS 8.2%. THE MEAN MAXIMAL ANGLE AND ANGLE WERE LARGER IN THE ISR GROUP (47 +/- 22 DEGREES VS. 37 +/- 21 DEGREES, P=0.004 AND 20 +/- 13 DEGREES VS 13 +/- 10 DEGREES, P<0.0001, RESPECTIVELY). INDEPENDENT PREDICTORS OF ISR WERE ANGLE, HEMODIALYSIS, AORTIC OSTIUM STENTING, AND DIABETES MELLITUS. HINGE MOTION-ASSOCIATED ISR (ANGLE 16 DEGREES) OCCURRED IN 28 LESIONS: STENT FRACTURE IN 9, STENT RECOIL IN 6, EDGE INJURY IN 10, AND OTHERS IN 3. CONCLUSIONS: THE AMOUNT OF HINGE MOTION IN TORTUOUS LESIONS SHOULD BE CONSIDERED IN THE SELECTION OF DRUG ELUTING STENT TYPES. CLINICAL IMPLICATIONS: WITH THE INCREASING USE OF DESS, PCI IS BEING APPLIED TO INCREASING NUMBERS OF COMPLEX LESIONS, INCLUDING TORTUOUS ONES WITH HINGE MOTION. WE DETERMINED THAT HINGE MOTION WAS ONE OF THE PREDICTORS OF ISR AFTER IMPLANTATION OF SESS, WHICH HAVE A CLOSED-CELL DESIGN. SECOND GENERATION DESS INCLUDING THE ZOTAROLIMUS-ELUTING STENT AND THE VEROLIMUS-ELUTING STENT HAVE AN OPEN-CELL DESIGN AND BETTER CONFORMABILITY AND FLEXIBILITY. THESE STENTS MIGHT FAVOR LOWER ISR RATES AFTER DES IMPLANTATION FOR TORTUOUS LESIONS WITH HINGE MOTION. THE ANGLE IN THE TARGET LESION CAN BE MEASURED EASILY AND QUICKLY BEFORE THE PROCEDURE, WITHOUT ANY ADDITIONAL EQUIPMENT, SUCH AS AN IVUS. THE SELECTION OF DES TYPES BASED ON THE ANGLE BEFORE THE PROCEDURE MIGHT PROVIDE A BETTER REDUCTION OF SUBSEQUENT ISR. CONCLUSION: THE ANGLE WAS ONE OF THE PREDICTORS OF ISR AFTER SES IMPLANTATION. THE AMOUNT OF HINGE MOTION IN TORTUOUS LESIONS SHOULD BE CONSIDERED IN THE SELECTION OF DES TYPES. THE PRODUCT(S) REMAINS IMPLANTED IN THE PATIENT AND IS/ARE THUS NOT AVAILABLE FOR EVALUATION. A REVIEW OF THE MANUFACTURING RECORDS COULD NOT BE CONDUCTED WITHOUT A LOT NUMBER. RESTENOSIS IS A KNOWN POTENTIAL ADVERSE EVENT FOLLOWING STENT IMPLANTATION AND IS OFTEN ASSOCIATED WITH THE PROGRESSION OF CARDIOVASCULAR DISEASE. PATIENTS WHO ARE KNOWN TO BE AT HIGH-RISK FOR RESTENOSIS INCLUDE THOSE WITH DIABETES, LONG LESIONS, SMALL VESSELS, BIFURCATIONS, AND RESTENOTIC LESIONS. REVIEW OF THE INFORMATION PROVIDED SUGGESTS THAT THERE ARE VESSEL/LESION FACTORS (HINGE MOTION) THAT MAY HAVE CONTRIBUTED TO THIS PATIENT'S RESTENOTIC EVENT. THERE IS NO INDICATION OF A DESIGN OR MANUFACTURING RELATED ISSUE THEREFORE NO CORRECTIVE ACTION IS REQUIRED.
THIS DEVICE (B)(4) (LOT UNKNOWN) IS DISTRIBUTED OUTSIDE THE UNITED STATES ; HOWEVER IT IS SIMILAR TO THE UNITED STATES PRODUCT (B)(4). THE PRODUCT REMAINS IMPLANTED IN THE PATIENT AND IS NOT AVAILABLE FOR ANALYSIS. ADDITIONAL INFORMATION WILL BE SUBMITTED WITHIN THIRTY DAYS UPON RECEIPT. (B)(4).
PER THE ARTICLE "IMPACT OF HINGE MOTION ON IN-STENT RESTENOSIS AFTER SIROLIMUS-ELUTING STENT IMPLANTATION," ALL PATIENTS WERE INCLUDED IN THE STUDY BETWEEN 2004 AND 2007. THIS PATIENT HAD ONE 2.5 X 18MM CYPHER STENT IMPLANTED TO TREAT SEVERE STENOSIS OF THE LEFT CIRCUMFLEX ARTERY. THE TARGET LESION HAD A HINGE MOTION WITH 47 DEGREE ANGULATION. AT THE (B)(6) FOLLOW-UP SEVERE IN-STENT RESTENOSIS WAS NOTED AT THE DISTAL EDGE OF THE STENT. THE HINGE POINT HAD SHIFTED TO THE DISTAL EDGE OF THE STENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | CYPHER SIROLIMUS-ELUTING CORONARY STENT | DRUG-ELUTING STENT (NIQ) | NIQ | CORDIS DE MEXICO | NA | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization| R |