PROWLER SELECT
Report
- Report Number
- 3008114965-2025-00322
- Event Type
- Malfunction
- Date Received
- April 23, 2025
- Date of Event
- March 24, 2025
- Report Date
- April 23, 2025
- Manufacturer
- MEDOS INTERNATIONAL SARL
- Product Code
- KRA
- UDI-DI
- 10886704028888
- PMA / PMN Number
- K021591
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
MANUFACTURER¿S REF. NO: (B)(4). INFORMATION REGARDING PATIENT IDENTIFIER, DATE OF BIRTH, AGE, SEX, GENDER, WEIGHT, RACE, AND ETHNICITY WERE NOT PROVIDED. SECTION E.1: THE INITIAL REPORTER PHONE IS NOT AVAILABLE / REPORTED. BASED ON COMPLAINT INFORMATION, THE DEVICE IS NOT AVAILABLE TO BE RETURNED FOR ANALYSIS. A REVIEW OF MANUFACTURING DOCUMENTATION ASSOCIATED WITH THIS LOT (31454976) PRESENTED NO ISSUES DURING THE MANUFACTURING OR INSPECTION PROCESSES RELATED TO THE REPORTED COMPLAINT. THERE WERE NO INTERNAL ACTIONS RELATED TO DEVICE MANUFACTURE OR INSPECTION. PRODUCT ANALYSIS CANNOT BE CONDUCTED AS THE PRODUCT WAS NOT RETURNED FOR ANALYSIS. NO DETERMINATION OF CAUSES AND POSSIBLE CONTRIBUTING FACTORS COULD BE MADE. AS SUCH, THE INVESTIGATION WILL BE CLOSED. WITH THE LIMITED INFORMATION AVAILABLE AND WITHOUT THE PRODUCT AVAILABLE FOR ANALYSIS, THE REPORTED ISSUE DOCUMENTED IN THE COMPLAINT COULD NOT BE CONFIRMED. BASED ON THE MANUFACTURING DOCUMENTATION REVIEW, THERE IS NO INDICATION THAT THE EVENT IS RELATED TO THE DEVICE MANUFACTURING PROCESS. THE EXACT CAUSE OF THE EVENT COULD NOT BE CONCLUSIVELY DETERMINED; HOWEVER, IT IS POSSIBLE THAT CIRCUMSTANCES OF THE PROCEDURE AND / OR DEVICE MANIPULATION / INTERACTION MAY HAVE CONTRIBUTED TO THE REPORTED FAILURE. AS PART OF THE POST MARKET SURVEILLANCE PROGRAM, INFORMATION FROM THIS COMPLAINT IS TRENDED FOR STATISTICAL SIGNALS AND CORRECTIVE / PREVENTIVE ACTION MAY BE TRIGGERED LATER. SINCE THERE WAS NO EVIDENCE TO SUGGEST THE EVENT WAS RELATED TO A MANUFACTURING OR DESIGN ISSUE, NO CORRECTIVE ACTIONS WILL BE TAKEN AT THIS TIME. THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY JOHNSON & JOHNSON MEDTECH, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, JOHNSON & JOHNSON MEDTECH, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. MISSING INFORMATION FROM THIS REPORT IS IDENTIFIED AS BLANK; THIS INFORMATION WAS NOT PROVIDED IN THE REPORTED EVENT OR AVAILABLE AT THE TIME OF REPORT SUBMISSION. THE MANUFACTURER WILL SUBMIT A SUPPLEMENTAL REPORT IF NEW FACTS ARISE WHICH MATERIALLY ALTER INFORMATION SUBMITTED IN A PREVIOUS MDR REPORT. ADDITIONAL INFORMATION WILL BE SUBMITTED WITHIN 30 DAYS OF RECEIPT.
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE 4MM X 23MM NO TIP ENTERPRISE¿ 2 VASCULAR RECONSTRUCTION DEVICE (ENCR402300 / 9242471) WAS PLACED IN THE TARGET SITE AND THE PHYSICIAN TRIED TO RELEASE THE STENT, BUT THE PLACEMENT OF THE STENT WAS NOT IDEAL. THE PHYSICIAN RETRACTED THE STENT AND DELIVERED IT AGAIN, BUT THE STENT WAS IMPEDED IN THE TIP OF THE CONCOMITANT 150CM X 5CM PROWLER SELECT PLUS MICROCATHETER (606S255X / 31454976) AND COULD NOT PASS THROUGH IT. THE PHYSICIAN REMOVED THE STENT AND THE MICROCATHETER FROM THE PATIENT AND REPLACED BOTH DEVICES COMPETITOR BRAND DEVICES TO COMPLETE THE PROCEDURE WHICH WAS REPORTEDLY PROLONGED BY 15 MINUTES. THERE WAS NO REPORT OF ANY NEGATIVE IMPACT TO THE PATIENT. ON 14-APR-2025, ADDITIONAL INFORMATION WAS RECEIVED. PER THE INFORMATION, THE PROCEDURE WAS TARGETING THE M1 SEGMENT OF THE MIDDLE CEREBRAL ARTERY. THE OBJECTIVE OF THE PROCEDURE WAS ¿BALL EXPANSION, STENT TO IMPROVE BLOOD FLOW, REDUCE THE RISK OF VASCULAR OCCLUSION.¿ AN ADEQUATE CONTINUOUS FLUSH WAS MAINTAINED THROUGH THE MICROCATHETER. THERE HAD BEEN NO RESISTANCE DURING THE ADVANCEMENT OF THE STENT. WHEN THE STENT WAS REMOVED, IT WAS STILL ON THE DELIVERY WIRE. THERE WAS NO DAMAGE NOTED ON THE STENT / STENT DELIVERY SYSTEM. THERE WAS NO DAMAGE NOTED ON THE MICROCATHETER. PER THE INFORMATION, THERE WAS NO NEGATIVE IMPACT TO THE PATIENT. IT WAS NOT KNOWN IF THE REPORTED APPROXIMATE 15-MINUTES PROCEDURE EXTENSION WAS CONSIDERED CLINICALLY SIGNIFICANT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 629110 | PROWLER SELECT | CATHETER, CONTINUOUS FLUSH | KRA | MEDOS INTERNATIONAL SARL | 31454976 | 10886704028888 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | ENTERPRISE2 4MMX23MM NO TIP |