FDA Adverse Event Injury Summary report: N

UNICEL DXC 600 SYNCHRON CLINICAL SYSTEM

MDR report key: 2183678 · Received July 22, 2011

Report

Report Number
2050012-2011-03300
Event Type
Injury
Date Received
July 22, 2011
Date of Event
March 6, 2008
Report Date
March 6, 2008
Manufacturer
BECKMAN COULTER, INC.
Product Code
JGS
PMA / PMN Number
K042291
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
KY, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

TROUBLESHOOTING OF THE UNIT WAS PERFORMED BY THE CUSTOMER AND A FIELD SERVICE ENGINEER (FSE) VIA TELEPHONE. A CLEAR ROOT CAUSE FOR THIS EVENT HAS NOT YET BEEN DETERMINED TO DATE ALTHOUGH THIS EVENT APPEARS TO BE CONNECTED TO PERFORMING THE WEEKLY ION SELECTIVE ELECTRODE (ISE) MAINTENANCE PROCEDURE. THE CUSTOMER HAS BEEN PROVIDED WITH AN ALTERNATE WEEKLY VALIDATED ISE MAINTENANCE PROCEDURE TO MINIMIZE POTENTIAL ISE DRIFT. THIS REPORTABLE EVENT WAS IDENTIFIED DURING A RETROSPECTIVE REVIEW OF COMPLAINTS CONDUCTED BETWEEN (B)(4), 2008 AND (B)(4), 2010 FOR ADDITIONAL REPORTABLE EVENTS. THIS MDR REPRESENTS EVENT 2 OF 25 REPORTED BY THE CUSTOMER. THIS MDR IS RELATED TO THE FOLLOWING MDRS THAT HAVE BEEN REPORTED: 2050012-2011-03297, 03301, 03302, 03303, 03304, 03307, 03328, 03329, 03331, 03334, 03336, 03338, 03340, 03343, 03345, 03346, 03349, 03351, 03353, 03354, 03355, 03356, 03357, 03358.

Description of Event or Problem · 1

THE CUSTOMER CONTACTED BECKMAN COULTER, INC (BCI) TO REPORT THAT AFTER PERFORMING WEEKLY MAINTENANCE ON THEIR UNICEL DXC 600 SYNCHRON CLINICAL SYSTEM, THE SYSTEM OBTAINED ERRONEOUSLY LOW RESULTS FOR SODIUM (NA) AND CALCIUM (CALC) AND ERRONEOUSLY HIGH RESULTS FOR CHLORIDE (CL) FOR 25 PTS. THE ERRONEOUS TEST RESULTS WERE REPORTED OUTSIDE OF THE LAB. AN UNKNOWN NUMBER OF PTS WERE REPORTED TO HAVE HAD CHANGES TO PT TREATMENT AS A RESULT OF THIS EVENT. THE CUSTOMER STATED THAT THE QUALITY (QC) RUN IMMEDIATELY AFTER THE MAINTENANCE OBTAINED RESULTS WITHIN THE RANGES ESTABLISHED BY THE LABORATORY. THE CUSTOMER FURTHER STATED THAT THEIR PROCEDURE IS TO CALIBRATE POTASSIUM (K) EVERY 8 HOURS AND RUN AN ADDITIONAL QC OF ALL ANALYTES. DURING THIS QC, IT WAS DISCOVERED THAT NA, CL AND CALC WERE OUTSIDE OF THE ESTABLISHED RANGES. THIS IS REPORT 2 OF 25 MEDWATCH REPORTS FILED FOR THIS EVENT FOR PT 2 OF 25 PTS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 UNICEL DXC 600 SYNCHRON CLINICAL SYSTEM JGS BECKMAN COULTER, INC. NA NA

Patients

Seq Age Sex Outcome Treatment
1 80 YR Required Intervention