COULTER LH 750 HEMATOLOGY ANALYZER
Report
- Report Number
- 1061932-2011-00839
- Event Type
- Malfunction
- Date Received
- July 8, 2011
- Date of Event
- March 19, 2008
- Report Date
- April 28, 2008
- Manufacturer
- BECKMAN COULTER, INC.
- Product Code
- GKZ
- PMA / PMN Number
- K061574
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MO, US
- Reporter Occupation
- OTHER
Narratives
THE CUSTOMER DISCOVERED THIS EVENT WHEN THEY PERFORMED DIFFERENTIALS FOR A COMPARISON STUDY VS. A COMPETITOR ANALYZER. THE CUSTOMER USES SUSPECT MESSAGES (I.E. FLAGGING) FOR AUTO-VERIFICATION AND THE SAMPLE DATA PROVIDED WOULD NOT HAVE REQUIRED A MANUAL REVIEW OF THE BLOOD SMEAR. THE INSTRUMENT WAS PERFORMING WITHIN QUALITY CONTROL (QC) SPECS. CONTROLS WERE RUN EVERY 8 HOURS AND WERE RUN BEFORE AND AFTER THE INCIDENT. QC WAS ACCEPTABLE. FLAGGING PREFERENCES ARE SET TO '1101' (LOW LEVEL FOR BLAST, VARIANT LYMPH, AND IMM NE 2; IMM NE 1 IS SET TO OFF). NOTE: IMM NE 1 IS A FLAG FOR SUSPECT IMMATURE NEUTROPHILS, PRIMARILY BANDS. IMM NE 2 IS A FLAG FOR SUSPECT IMMATURE NEUTROPHILS, PRIMARILY METAMYELOCYTES, MYELOCYTES, AND PROMYELOCYTES. RAW DATA FILES WERE REQUESTED, BUT ARE NO LONGER AVAILABLE. SVC WAS NOT REQUESTED FOR THE ANALYZER. THE ROOT CAUSE FOR THE ERRONEOUS DIFFERENTIALS/FALSE NEGATIVE FLAGS IS UNK. THIS REPORTABLE EVENT WAS IDENTIFIED DURING A RETROSPECTIVE REVIEW CONDUCTED BETWEEN (B)(4) 2008 AND (B)(4) 2011 OF COMPLAINTS FOR ADDITIONAL EVENTS. THIS MDR REPRESENTS EVENT 9 OF 9 REPORTED BY THIS CUSTOMER. THIS MDR IS RELATED TO THE FOLLOWING MDRS THAT HAVE BEEN REPORTED: MDR 1061932-2011-00829, 00830, 00831, 00832, 00833, 00834, 00835, 00836.
CUSTOMER REPORTED ERRONEOUS DIFFERENTIAL TEST RESULTS WERE OBTAINED WHEN USING A COULTER LH 750 HEMATOLOGY ANALYZER. TEST RESULTS WERE DETERMINED TO BE ERRONEOUS WHEN COMPARED TO A MANUAL BLOOD SMEAR DIFFERENTIAL THAT CONTAINED IMMATURE WHITE BLOOD CELLS. THE AUTOMATED DIFFERENTIAL DID NOT HAVE INSTRUMENT GENERATED FLAGS. ERRONEOUS TEST RESULTS WERE RELEASED OUTSIDE THE LAB. IT IS UNK IF PT TREATMENT WAS AFFECTED. NO REPORTS OF DEATH OR SERIOUS INJURY AS A RESULT OF THIS EVENT. THIS EVENT REPRESENTS EVENT 9 OF 9 EVENTS REPORTED BY THIS CUSTOMER FOR SAMPLES TESTED OVER SEPARATE DAYS FOR THE FIRST OF THREE ANALYZERS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | COULTER LH 750 HEMATOLOGY ANALYZER | GKZ | BECKMAN COULTER, INC. | NA | NA |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | UNK |