FDA Adverse Event Injury Summary report: N

AZUR SOFT3D DETACHABLE 10

MDR report key: 21802035 · Received April 8, 2025

Report

Report Number
2032493-2025-90053
Event Type
Injury
Date Received
April 8, 2025
Date of Event
March 18, 2025
Report Date
April 8, 2025
Manufacturer
MICROVENTION, INC.
Product Code
KRD
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

THE PRODUCT REPORTED IN THIS REPORT IS AN EXPORT DEVICE NOT CLEARED OR APPROVED FOR MARKETING IN THE US. THIS COMPLAINT IS BEING REPORTED BASED ON THIS PRODUCT MEETING SIMILAR PRODUCT CRITERIA (SIMILAR TO V-TRAK HYDROSOFT 3D, 510(K)# K161367). THE PHYSICAL DEVICE WAS NOT AVAILABLE FOR EVALUATION TO INVESTIGATE IF A CONDITION EXISTED THAT WOULD HAVE CONTRIBUTED TO EVENT. SUPPLEMENTAL IMAGING WAS ALSO UNAVAILABLE FOR REVIEW; WITHOUT IMAGING, THE INVESTIGATION CANNOT VERIFY THE EVENT OCCURRED AS DESCRIBED, NOR COULD THE INVESTIGATION FURTHER EXAMINE THE CAUSE OF THE REPORTED EVENT. THIS INFORMATION MAY BE UPDATED IF ADDITIONAL INFORMATION IS PROVIDED AT A LATER DATE. BATCH REVIEW: A SEARCH FOR NON-CONFORMANCES ASSOCIATED WITH THIS PART/LOT NUMBER COMBINATION DID NOT REVEAL ANY PRODUCTION-RELATED ISSUES RELEVANT TO THE COMPLAINT THAT OCCURRED DURING MANUFACTURING OF THE DEVICE. COMPLAINT SYSTEM REVIEW: THERE ARE NO SIMILAR COMPLAINTS BASED ON THE COMPLAINT CATEGORY REGARDING THIS BATCH NUMBER FROM THE LAST TWO YEARS RECORDED IN THE COMPLAINT SYSTEM AT THE TIME OF THIS INVESTIGATION. BASED ON A REVIEW OF THE DEVICE¿S RISK DOCUMENTATION, THE REPORTED EVENT DID NOT INDICATE THERE WERE THE PRESENCE OF ANY POTENTIAL OR NEW MANUFACTURING, DESIGN, QUALITY, OR OTHER SYSTEMIC ISSUES, OR NON-CONFORMANCES. THE COMPLAINT CODE IS MONITORED THROUGH THE TRENDING PROCESS; CORRECTIVE ACTION IS DETERMINED, AS NEEDED, THROUGH THIS PROCESS. INVESTIGATIONS OF HISTORIC COMPLAINT FILES WITH SIMILAR COMPLAINT CATEGORY CODING ARE RECORDED IN THE COMPLAINT HANDLING SYSTEM; WITHOUT THE ABILITY TO PERFORM AN ANALYSIS OF THE DEVICE, THIS INVESTIGATION CANNOT IDENTIFY WITH CERTAINTY ANY POTENTIAL ROOT CAUSES. IF ANY ADDITIONAL INFORMATION IS RECEIVED AT A LATER DATE, AN INVESTIGATION WILL BE PERFORMED AND A SUPPLEMENTAL MDR WILL BE SUBMITTED. ¿ IFU REVIEW (ADDITIONAL INFORMATION CAN BE FOUND IN THE IFU): PLEASE REFER TO THE JAPANESE IFU FOR PRECAUTIONS, WARNINGS, AND FURTHER INFORMATION. THE FOLLOWING IS TAKEN FROM THE ENGLISH VERSION: 5. INTRODUCTION AND DEPLOYMENT OF THE COIL DELIVERY SYSTEM 5-3 SEAT THE DISTAL TIP OF THE INTRODUCER SHEATH AT THE DISTAL END OF THE MICROCATHETER HUB AND CLOSE THE RHV LIGHTLY AROUND THE INTRODUCER SHEATH TO SECURE THE RHV TO THE INTRODUCER SHEATH. CAUTION·DO NOT OVER-TIGHTEN THE RHV AROUND THE INTRODUCER SHEATH. [EXCESSIVE TIGHTENING COULD DAMAGE THE PUSHER CATHETER SUCH AS KINKING.] 5-4 PUSH THE COIL INTO THE LUMEN OF THE MICROCATHETER. CAUTION·AVOID CATCHING THE COIL ON THE JUNCTION BETWEEN THE INTRODUCER SHEATH AND THE HUB OF THE MICROCATHETER. ·INITIATE TIMING USING A STOPWATCH OR TIMER AT THE MOMENT THE COIL ENTERS THE MICROCATHETER. 5-5 PUSH THE PUSHER CATHETER THROUGH THE MICROCATHETER UNTIL THE PROXIMAL END OF THE PUSHER CATHETER MEETS THE PROXIMAL END OF THE INTRODUCER SHEATH. LOOSEN THE RHV. RETRACT THE INTRODUCER SHEATH JUST OUT OF THE RHV. CLOSE THE RHV AROUND THE PUSHER CATHETER. CAUTION·AVOID KINKING THE PUSHER CATHETER AND INTRODUCER SHEATH. ·TO PREVENT PREMATURE HYDRATION OF THE AZUR SYSTEM, ENSURE THAT THERE IS FLOW FROM THE SALINE FLUSH 5-7 UNDER FLUOROSCOPIC GUIDANCE, SLOWLY ADVANCE THE COIL INTO THE VESSEL/ANEURYSM FROM THE TIP OF THE MICROCATHETER. 5-8 CONTINUE TO ADVANCE THE COIL INTO THE LESION UNTIL OPTIMAL DEPLOYMENT IS ACHIEVED. REPOSITION IF NECESSARY. CAUTION·IF THE COIL SIZE IS NOT SUITABLE, REMOVE AND REPLACE WITH ANOTHER MORE APPROPRIATELY SIZED COIL. ·DO NOT ROTATE THE PUSHER CATHETER DURING OR AFTER DEPLOYMENT OF THE COIL INTO THE VESSEL/ANEURYSM. [ROTATING THE PUSHER CATHETER MAY RESULT IN A STRETCHED COIL OR PREMATURE DETACHMENT OF THE COIL FROM THE PUSHER CATHETER, WHICH COULD RESULT IN COIL MIGRATION.]

Description of Event or Problem · 0

AS REPORTED AN ANGIOGRAPHIC CATHETER WAS ENGAGED TO THE CELIAC ARTERY AND A MICROCATHETER WAS INSERTED INTO THE PANCREATIC ARCADE. SIX AZUR SOFT3D COILS WERE PLACED IN A STACK FROM THE DISTAL PART OF THE U-SHAPED VESSEL. THE COIL WAS USED AS THE SEVENTH COIL AND DURING INSERTION AND RETRACTION OF THE COIL TO BE PLACED IN A GAP WHERE BLOOD FLOW REMAINED, THE IMPLANT BECAME STRETCHED. THE STRETCHED IMPLANT WAS RETRIEVED WITH A SNARE AND REMOVED FROM THE PATIENT. AFTER CONFIRMING THAT NO IMPLANT REMAINED, THE COIL WAS REPLACED WITH ANOTHER COIL OF A DIFFERENT SIZE TO CONTINUE THE PROCEDURE. SUBSEQUENTLY, THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THE DEVICE WAS DISCARDED AND NOT AVAILABLE FOR RETURN AND INVESTIGATION. THERE WAS NO PATIENT HEALTH DAMAGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1757953 AZUR SOFT3D DETACHABLE 10 DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION KRD MICROVENTION, INC. MV-HS00520 0000726498

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention