BD INTIMA-II Y 20GAX1.16IN PRN/EC SLM
Report
- Report Number
- 3006948883-2025-00052
- Event Type
- Malfunction
- Date Received
- April 4, 2025
- Date of Event
- February 10, 2025
- Report Date
- April 15, 2025
- Manufacturer
- BD SUZHOU (MDS)
- Product Code
- FOZ
- UDI-DI
- 00382903830121
- PMA / PMN Number
- UNK
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CH
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
- Health Professional
- Yes
Narratives
H.3. IF A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS COMPLETED, A SUPPLEMENTAL REPORT WILL BE FILED.
1. DHR/BHR REVIEW (LOT#4081482): 1) THE PRODUCTS OF THIS BATCH WERE ASSEMBLED AT INTIMA II AUTO LINE 4 IN APRIL 2024 AND PACKAGED AT R240 PACKAGE LINE IN APRIL 2024. WORK ORDER QUANTITY WAS (B)(4) PCS. 2) THE SEPTUM INCOMING INSPECTIONS: APPEARANCE AND SIZE WERE NOT ABNORMAL, WHICH MET THE REQUIREMENTS OF INCOMING INSPECTION SPECIFICATIONS. 3) THE LEAKAGE TEST RESULTS OF 400PCS IN PROCESS TESTING AND 32PCS IN OUTGOING TESTING WERE WITHIN THE PRODUCT SPECIFICATIONS. 4) NO UNQUALIFIED, DEVIATION OR REWORK ACTIVITIES IN THE PRODUCTION PROCESS. 5) THE SEPTUM ASSEMBLY EQUIPMENT WITHOUT ABNORMAL MAINTENANCE. 2. NO DEFECTIVE SAMPLE AND PHOTO HAVE BEEN RECEIVED FOR THE COMPLAINT. 3. PERFORMED SEPTUM LEAKAGE TEST FOR THE RETAINED SAMPLES OF THIS BATCH, AND NO COMPLAINT DEFECTS ARE FOUND. 4. POSSIBLE CAUSES: 1) AFTER THE NEEDLE IS PIERCED INTO THE VEIN, THERE IS BLOOD AT THE NOTCH OF THE NEEDLE. IN THE PROCESS OF NEEDLE REMOVAL, ALTHOUGH THE PERFORATION OF THE SEPTUM IS CLOSED, THE BLOOD DROPS IN THE NOTCH WILL BE BROUGHT OUT WITH THE NOTCH. IF THERE IS A LOT OF INERTIA IN THE NEEDLE REMOVAL PROCESS, BLOOD DROPS WILL BE THROWN OUT. 2) IF THE PATIENT'S ARM IS TIED TIGHT DURING THE PUNCTURE, IT WILL CAUSE GREAT PRESSURE IN THE VEIN, AND BLOOD WILL COME OUT WITH THE NEEDLE WHEN THE NEEDLE IS PULLED OUT, BUT THE SUBSEQUENT BLOOD LEAKAGE WILL NOT BE SUSTAINED. CONCLUSION(S): NO ABNORMALITY IS FOUND ON PROCESS AND RETAINED SAMPLE. AS NO DEFECTIVE SAMPLE HAS BEEN RECEIVED, RELEVANT TESTS CANNOT BE PERFORMED, THE ROOT CAUSE OF LEAKAGE CANNOT BE DETERMINED. THE PLANT WILL CONTINUE TO TRACK AND TREND FOR THIS ISSUE.
IT WAS REPORTED THAT BD INTIMA-II Y 20GAX1.16IN PRN/EC SLM LEAKED AT SEPTUM THE PATIENT UNDERWENT AN MRI ENHANCEMENT, WHICH REQUIRED A RED INDWELLING NEEDLE. AFTER THE PUNCTURE WAS COMPLETED, THE END OF THE INDWELLING NEEDLE BLED AFTER THE NEEDLE CONE WAS WITHDRAWN, AND IT WAS NOT SEALED. AFTER THE PUNCTURE WAS DISCOVERED, IT WAS IMMEDIATELY REPLACED WITH A NEW INDWELLING NEEDLE AND RE-PUNCTURE WAS PERFORMED.
NO ADDITIONAL INFORMATION IS AVAILABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1001406 | BD INTIMA-II Y 20GAX1.16IN PRN/EC SLM | INTRAVASCULAR CATHETER | FOZ | BD SUZHOU (MDS) | 4081482 | 00382903830121 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown |