GORE® DRYSEAL FLEX INTRODUCER SHEATH
Report
- Report Number
- 3007284313-2025-03821
- Event Type
- Injury
- Date Received
- March 11, 2025
- Date of Event
- February 14, 2025
- Report Date
- March 12, 2025
- Manufacturer
- W. L. GORE & ASSOCIATES, INC.
- Product Code
- DYB
- UDI-DI
- 00733132630073
- PMA / PMN Number
- K160254
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
H6: A REVIEW OF THE MANUFACTURING RECORDS FOR THE DEVICE VERIFIED THAT THE LOT MET ALL PRE-RELEASE SPECIFICATIONS. H6: CODE D12: ACCORDING TO THE GORE® DRYSEAL FLEX INTRODUCER SHEATH INSTRUCTIONS FOR USE (IFU), CAREFUL EVALUATION OF VESSEL SIZE, ANATOMY, TORTUOSITY, AND DISEASE STATE (INCLUDING CALCIFICATION, PLAQUE, AND THROMBUS) IN ACCORDANCE WITH THE OBSERVATION IN THE CT IMAGE OR ANGIOGRAPHY OBTAINED BY PRE-OPERATION/OPERATION OR VISUAL OBSERVATION OBTAINED BY OPERATION IS REQUIRED TO ENSURE SUCCESSFUL USE OF GORE® DRYSEAL FLEX INTRODUCER SHEATH. [IF VESSEL SIZE IS SMALLER THAN THE INTRODUCER SHEATH OUTER DIAMETER OR IF VESSEL IS NOT ADEQUATE FOR ACCESS, MAJOR BLEEDING, VESSEL DAMAGE, OR EMBOLISM, MAY RESULT. ADDITIONALLY, THE IFU STATES: ADVERSE EVENTS THAT MAY OCCUR AND / OR REQUIRE INTERVENTION INCLUDE, BUT ARE NOT LIMITED TO VASCULAR TRAUMA (I.E., DISSECTION, RUPTURE, PERFORATION, TEAR, ETC.). W. L. GORE & ASSOCIATES, INC. (GORE) IS SUBMITTING THIS REPORT TO COMPLY WITH 21 C.F.R. PART 803, THE MEDICAL DEVICE REPORTING REGULATION. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY GORE, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. BLANK FIELDS PRESENT ON THIS REPORT INCLUDE REQUIRED FIELDS AND FIELDS DETERMINED TO BE NOT APPLICABLE. BLANK REQUIRED FIELDS INDICATE THAT THE INFORMATION WAS NOT PROVIDED, WAS DEEMED UNAVAILABLE OR WAS NOT APPLICABLE. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, GORE, OR ITS ASSOCIATES THAT THE DEVICE, GORE OR ITS ASSOCIATES CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE A LEGAL ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY DEFECTS OR HAS MALFUNCTIONED, AS DEFINED FROM A LEGAL STANDPOINT. THESE WORDS ARE INCLUDED IN THE REPORT AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE FDA, TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REPORTING PURSUANT TO PART 803. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT.
THE FOLLOWING INFORMATION WAS REPORTED TO GORE: ON (B)(6) 2025, THIS PATIENT UNDERWENT ENDOVASCULAR TREATMENT FOR A THORACIC AORTIC ANEURYSM USING GORE® TAG® CONFORMABLE THORACIC STENT GRAFT WITH ACTIVE CONTROL SYSTEM AND GORE® DRYSEAL FLEX INTRODUCER SHEATH AS AN ACCESSORY. A 22FR SHEATH WAS INSERTED VIA THE LEFT FEMORAL ARTERY, BUT THERE WAS RESISTANCE WHILE ADVANCING IT. AFTER DEPLOYING THE STENT GRAFT, ANGIOGRAPHY REVEALED A DISSECTION FROM THE LEFT COMMON ILIAC ARTERY TO THE EXTERNAL ILIAC ARTERY. AN ADDITIONAL STENT GRAFT WAS PLACED AT THE DISSECTION SITE AS A TREATMENT. THE PATIENT TOLERATED THE PROCEDURE. THE PHYSICIAN¿S COMMENT: ¿THE DISSECTION WAS ANTICIPATED. THERE WAS NO BLEEDING OUTSIDE THE VESSEL."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1559761 | GORE® DRYSEAL FLEX INTRODUCER SHEATH | INTRODUCER, CATHETER | DYB | W. L. GORE & ASSOCIATES, INC. | 00733132630073 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 84 YR | Male | Required Intervention |