MEDTRONIC TRANSCATHETER VALVE
Report
- Report Number
- 2025587-2025-01514
- Event Type
- Injury
- Date Received
- February 27, 2025
- Date of Event
- November 25, 2024
- Report Date
- February 27, 2025
- Manufacturer
- MEDTRONIC HEART VALVES DIVISION
- Product Code
- NPT
- PMA / PMN Number
- P130021
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
CITATION: HENNING GUTHOFF ET AL. IMPACT OF MEASURED AND PREDICTED PROSTHESIS-PATIENT MISMATCH AFTER TRANSCATHETER AORTIC VALVE REPLA CEMENT. JACC CARDIOVASC INTERV NOV 25;17(22):2626-2635. 2024. 10.1016/J.JCIN.2024.08.041. EARLIEST DATE OF PUBLICATION USED FOR DATE OF EVENT. NO UNIQUE DEVICE IDENTIFIER (SERIAL/LOT) NUMBERS WERE PROVIDED; WITHOUT THIS INFORMATION IT COULD NOT BE DETERMINED WHETHER THESE OBSERVATIONS HAVE BEEN PREVIOUSLY REPORTED. WITHOUT RETURN OF THE PRODUCT NO DEFINITIVE CONCLUSION CAN BE MADE REGARDING THE CLINICAL OBSERVATIONS. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
LITERATURE WAS REVIEWED REGARDING IMPACT OF MEASURED AND PREDICTED PROSTHESIS-PATIENT MISMATCH AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT. THE STUDY POPULATION INCLUDED 38,808 PATIENTS WHO WERE PREDOMINANTLY MALE WITH A MEAN AGE OF 81 YEARS OLD. MULTIPLE MANUFACTURER¿S DEVICES WERE IMPLANTED IN THE STUDY POPULATION; AN UNDISCLOSED NUMBER OF PATIENTS WERE IMPLANTED WITH A MEDTRONIC COREVALVE, EVOLUT R, EVOLUT PRO OR EVOLUT PRO+ BIOPROSTHETIC VALVE. DEATHS OCCURRED IN THE STUDY POPULATION; HOWEVER, THERE WAS NO STATEMENT ESTABLISHING A CAUSAL OR CONTRIBUTORY RELATIONSHIP BETWEEN MEDTRONIC PRODUCT AND THE DEATHS. AMONG ALL PATIENTS, CLINICAL OBSERVAT IONS INCLUDED: PATIENT-PROSTHESIS MISMATCH, MODERATE TO SEVERE PARAVALVULAR LEAK, STROKE, AND ARRHYTHMIA REQUIRING PERMANENT PACEMAKER IMPLANT. NO FURTHER INFORMATION WAS PROVIDED PERTAINING TO MEDTRONIC PRODUCTS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 665141 | MEDTRONIC TRANSCATHETER VALVE | AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIV | NPT | MEDTRONIC HEART VALVES DIVISION | MDT-TRANS VALVE |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 81 YR | Male | Required Intervention| H| L |