MEDTRONIC TRANSCATHETER VALVE
Report
- Report Number
- 2025587-2025-01248
- Event Type
- Injury
- Date Received
- February 14, 2025
- Date of Event
- August 30, 2024
- Report Date
- February 14, 2025
- Manufacturer
- MEDTRONIC HEART VALVES DIVISION
- Product Code
- NPT
- PMA / PMN Number
- P130021
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
CITATION: IWATA ET AL. LONG-TERM IMPACT OF GENDER DIFFERENCES AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION. CJC OPEN. 2024 AUG 30;6 (12):1453-1461. DOI: 10.1016/J.CJCO.2024.08.012. EARLIEST DATE OF PUBLICATION USED FOR DATE OF EVENT. NO UNIQUE DEVICE IDENTIFIER (SERIAL/LOT) NUMBERS WERE PROVIDED; WITHOUT THIS INFORMATION IT COULD NOT BE DETERMINED WHETHER THESE OBSERVATIONS HAVE BEEN PREVIOUSLY REPORTED. WITHOUT RETURN OF THE PRODUCT NO DEFINITIVE CONCLUSION CAN BE MADE REGARDING THE CLINICAL OBSERVATIONS. SELECT PATIENT INFORMATION CANNOT BE INCLUDED IN REGULATORY REPORT DUE TO REGIONAL PRIVACY REGULATIONS. MEDTRONIC SUBMITS THIS REPORT TO COMPLY WITH FDA REGULATIONS 21 CFR PARTS 4 AND 803. MEDTRONIC HAS MADE REASONABLE EFFORTS TO PROVIDE AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MEDTRONIC, OR ITS EMPLOYEES THAT THE DEVICE, MEDTRONIC, OR ITS EMPLOYEE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. MEDTRONIC WILL SUBMIT A SUPPLEMENTAL REPORT IF ADDITIONAL RELEVANT INFORMATION BECOMES KNOWN.
LITERATURE WAS REVIEWED REGARDING THE LONG-TERM IMPACT OF GENDER DIFFERENCES AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI). THE STUDY POPULATION INCLUDED 511 PATIENTS. MULTIPLE MANUFACTURER¿S DEVICES WERE IMPLANTED IN THE STUDY POPULATION; 63 PATIENTS WERE IMPLANTED WITH A MEDTRONIC COREVALVE (N=11), EVOLUT R (N=44), OR EVOLUT PRO (N=8) BIOPROSTHETIC VALVE. DEATHS OCCURRED IN THE STUDY POPULATION; HOWEVER, THERE WAS NO STATEMENT ESTABLISHING A CAUSAL OR CONTRIBUTORY RELATIONSHIP BETWEEN MEDTRONIC PRODUCT AND THE DEATHS. AMONG ALL PATIENTS, CLINICAL OBSERVATIONS INCLUDED: HYPERATTENUATED LEAFLET THICKENING (HALT), STROKE, MAJOR BLEEDING OR VASCULAR COMPLICATION, ARRHYTHMIA REQUIRING PERMANENT PACEMAKER IMPLANT, MODERATE PARAVALVULAR LEAK, SEVERE PATIENT-PROSTHESIS MISMATCH, AND CONGESTIVE HEART FAILURE WITH HOSPITALIZATION. NO FURTHER INFORMATION WAS PROVIDED PERTAINING TO MEDTRONIC PRODUCTS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1623184 | MEDTRONIC TRANSCATHETER VALVE | AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIV | NPT | MEDTRONIC HEART VALVES DIVISION | MDT-TRANS VALVE |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Life Threatening| H| R |