FDA Adverse Event Injury Summary report: N

CUSTOM-MADE RELAY PRO NBS THORACIC STENT-GRAFT SYSTEM

MDR report key: 21326867 · Received February 6, 2025

Report

Report Number
2247858-2025-00034
Event Type
Injury
Date Received
February 6, 2025
Date of Event
January 17, 2025
Report Date
July 11, 2025
Manufacturer
BOLTON MEDICAL, INC.
Product Code
MIH
PMA / PMN Number
P200045
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

BOLTON MEDICAL IS VOLUNTARILY REPORTING AN EVENT RELATED TO A RELAY PRO CUSTOM-MADE DEVICE. THE CUSTOM MADE RELAY PRO DEVICES ARE NOT MARKETED IN THE US, HOWEVER THEY ARE SIMILAR TO THE RELAY THORACIC STENT GRAFT WITH PRO DELIVERY SYSTEM APPROVED FOR SALE IN THE US (P200045). THE EVENT OCCURRED IN GERMANY. BOLTON MEDICAL, INC. (D/B/A TERUMO AORTIC), HEREIN KNOWN AS THE "COMPANY", IS SUBMITTING THIS REPORT PURSUANT TO 21 CFR PART 803, HAS MADE REASONABLE EFFORTS TO OBTAIN COMPLETE INFORMATION, AND HAS PROVIDED AS MUCH AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT IS BASED ON INFORMATION OBTAINED BY THE COMPANY, WHICH MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE REGULATIONS. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN, UNAVAILABLE, OR NOT APPLICABLE. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY ANYONE THAT THE DEVICE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE A LEGAL ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY DEFECTS OR HAS MALFUNCTIONED, AS DEFINED FROM A LEGAL STANDPOINT. THESE WORDS ARE INCLUDED IN THE REPORT AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE CERTAIN REGULATIONS, TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REPORTING PURSUANT TO PART 803. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT.

Additional Manufacturer Narrative · 0

BOLTON MEDICAL IS VOLUNTARILY REPORTING AN EVENT RELATED TO A RELAY PRO CUSTOM-MADE DEVICE. THE CUSTOM MADE RELAY PRO DEVICES ARE NOT MARKETED IN THE US, HOWEVER THEY ARE SIMILAR TO THE RELAY THORACIC STENT GRAFT WITH PRO DELIVERY SYSTEM APPROVED FOR SALE IN THE US (P200045). THE EVENT OCCURRED IN GERMANY. BOLTON MEDICAL, INC. (D/B/A TERUMO AORTIC), HEREIN KNOWN AS THE "COMPANY", IS SUBMITTING THIS REPORT PURSUANT TO 21 CFR PART 803, HAS MADE REASONABLE EFFORTS TO OBTAIN COMPLETE INFORMATION, AND HAS PROVIDED AS MUCH AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT IS BASED ON INFORMATION OBTAINED BY THE COMPANY, WHICH MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE REGULATIONS. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN, UNAVAILABLE, OR NOT APPLICABLE. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY ANYONE THAT THE DEVICE CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. IN PARTICULAR, THIS REPORT DOES NOT CONSTITUTE A LEGAL ADMISSION BY ANYONE THAT THE PRODUCT DESCRIBED IN THIS REPORT HAS ANY DEFECTS OR HAS MALFUNCTIONED, AS DEFINED FROM A LEGAL STANDPOINT. THESE WORDS ARE INCLUDED IN THE REPORT AND ARE FIXED ITEMS FOR SELECTION CREATED BY THE CERTAIN REGULATIONS, TO CATEGORIZE THE TYPE OF EVENT SOLELY FOR THE PURPOSE OF REPORTING PURSUANT TO PART 803. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT.

Description of Event or Problem · 0

"TWISTED LOADED STENT-GRAFT - PROX AND DISTAL END NOT IN LINE" PATIENT OUTCOME: "SO FAR FINE, DUE TO IN SITU LSA/LCCA BYPASS."

Description of Event or Problem · 0

"TWISTED LOADED STENT-GRAFT - PROX AND DISTAL END NOT IN LINE." PATIENT OUTCOME: "SO FAR FINE, DUE TO IN SITU LSA/LCCA BYPASS."

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
623650 CUSTOM-MADE RELAY PRO NBS THORACIC STENT-GRAFT SYSTEM STENT, ENDOVASCULAR GRAFT, AORTIC MIH BOLTON MEDICAL, INC. 2411040375

Patients

Seq Age Sex Outcome Treatment
1 NA Unknown Required Intervention