RG3
Report
- Report Number
- 3003775027-2025-00007
- Event Type
- Injury
- Date Received
- January 27, 2025
- Date of Event
- September 2, 2020
- Report Date
- January 28, 2025
- Manufacturer
- ASAHI INTECC CO., LTD.
- Product Code
- DQX
- PMA / PMN Number
- K141339
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IT
- Reporter Occupation
- PHYSICIAN
- Health Professional
- Yes
Narratives
MANUFACTURING SITE: MANUFACTURING SITE COULD NOT BE IDENTIFIED BECAUSE THE PRODUCT LOT NUMBER INFORMATION WAS NOT AVAILABLE. AS THE INFORMATION IN THIS REPORT WAS ENTIRELY BASED ON LITERATURE, WHICH DID NOT PROVIDE SUCH DETAILED DEVICE INFORMATION AS LOT NUMBER OR UNIQUE DEVICE IDENTIFIER (UDI), NO OTHER INFORMATION THAN THE BRAND NAME COULD BE OBTAINED. DEVICE EVALUATION COULD NOT BE PERFORMED BECAUSE THE AFFECTED DEVICES WERE NOT RETURNED. LOT HISTORY RECORDS REVIEW COULD NOT BE CONDUCTED BECAUSE LOT INFORMATION WAS UNAVAILABLE. ALL THE SHIPPED PRODUCTS WERE INSPECTED IN THE PRODUCTION PROCESS AND SATISFIED THE PRODUCT SPECIFICATIONS AND RELEASE CRITERIA; THEREFORE, IT WAS CONCLUDED THAT THERE WAS NO ANOMALY IN PRODUCT QUALITY. AS DESCRIBED IN THE LITERATURE, IT WAS PRESUMED THAT REMOVAL DIFFICULTY OF THE RG3 GUIDE WIRE WAS CAUSED BY THE BIOLOGICAL AORTIC VALVE PROSTHESIS. IT WAS CONCLUDED THAT THIS EVENT WAS NOT ATTRIBUTED TO PRODUCT QUALITY. NO CAPA WILL BE TAKEN. INSTRUCTIONS FOR USE (IFU) STATES: [WARNINGS] ~ OBSERVE MOVEMENT OF THIS GUIDE WIRE IN THE VESSELS. BEFORE THIS GUIDE WIRE IS MOVED OR TORQUED, THE TIP MOVEMENT SHOULD BE EXAMINED AND MONITORED UNDER FLUOROSCOPY. DO NOT MOVE OR TORQUE THE GUIDE WIRE WITHOUT OBSERVING CORRESPONDING MOVEMENT OF THE TIP. OTHERWISE, THE GUIDE WIRE MAY BE DAMAGED AND/OR VESSEL TRAUMA MAY OCCUR. IN ADDITION, ENSURE THAT THE DISTAL TIP OF THIS GUIDE WIRE AND ITS LOCATION IN THE VESSEL ARE VISIBLE DURING MANIPULATIONS OF THE GUIDE WIRE. ~ IF RESISTANCE IS FELT DUE TO SPASM, BENDING OF THE GUIDE WIRE, OR DUE TO TRAP WHILE OPERATING THIS GUIDE WIRE IN THE BLOOD VESSEL OR REMOVING IT, DO NOT TORQUE AND/OR PULL THE GUIDE WIRE ITSELF. STOP THE PROCEDURE. DETERMINE THE CAUSE OF RESISTANCE UNDER FLUOROSCOPY AND TAKE APPROPRIATE REMEDIAL ACTION. IF THE GUIDE WIRE IS MOVED EXCESSIVELY, IT MAY BREAK OR BECOME DAMAGED, WHICH MAY CAUSE BLOOD VESSEL INJURY OR RESULT IN FRAGMENTS BEING LEFT INSIDE THE VESSEL. [MALFUNCTION AND ADVERSE EFFECTS] ~ REMOVAL DIFFICULTY OF GUIDE WIRE.
IT WAS REPORTED THROUGH LITERATURE THAT ASAHI GUIDE WIRES: RG3 GUIDE WIRE, FIELDER XT-A GUIDE WIRE, ULTIMATEBROS 3 GUIDE WIRE, GAIA SECOND GUIDE WIRE, GAIA THIRD GUIDE WIRE, CONQUEST PRO GUIDE WIRE, CORSAIR PRO MICROCATHETER AND CARAVEL MICROCATHETER WERE TRAPPED IN PATIENT ANATOMY, REQUIRING ADDITIONAL TREATMENTS. PUBLICATION: EUROINTERVENTION 2021;17:212-219 TITLE: DEVICE ENTRAPMENT DURING PERCUTANEOUS CORONARY INTERVENTION OF CHRONIC TOTAL OCCLUSIONS: INCIDENCE AND MANAGEMENT STRATEGIES EXCERPT: [METHODS] * PATIENT POPULATION WE COLLECTED DATA ON 2,361 CONSECUTIVE CTO PCI PROCEDURES PERFORMED BY FIVE HIGH-VOLUME CTO OPERATORS (>100 CASES PER YEAR) IN ITALY BETWEEN (B)(6) 2015 AND (B)(6) 2020 TO IDENTIFY CASES OF DEVICE ENTRAPMENT. DATA WERE RETROSPECTIVELY COLLECTED FROM EACH CENTRE'S DATABASE. NO EXCLUSION CRITERIA WERE APPLIED. INFORMATION WAS OBTAINED FROM MEDICAL RECORDS AND ANGIOGRAMS. [RESULTS] A TOTAL OF 2,361 CONSECUTIVE CTO PCI PERFORMED BY FIVE HIGH-VOLUME CTO OPERATORS IN ITALY WERE REVIEWED. THE APPROACH WAS ANTEGRADE IN 1,486 CASES (62.9%) AND RETROGRADE IN 875 CASES (37.1%). DEVICE ENTRAPMENT OCCURRED IN 36 CASES (1.5%). ENTRAPPED DEVICES CONSISTED OF GUIDEWIRES (N=13, 0.5% OF CASES), MICROCATHETERS (N=6, 0.2%), BALLOONS (N=6, 0.2%), ROTATIONAL ATHERECTOMY BURRS (N=10, 0.4%) AND ONE GUIDE CATHETER EXTENSION (N=1; 0.04%). TABLE 3 SHOWS THE TYPES OF DEVICE, CAUSES LEADING TO THE ENTRAPMENT, RETRIEVAL TECHNIQUES AND OUTCOME. NINETEEN CASES OF DEVICE ENTRAPMENT OCCURRED DURING ANTEGRADE CTO PCI AND SEVENTEEN DURING A RETROGRADE APPROACH, WITH NO SIGNIFICANT DIFFERENCES BETWEEN GROUPS (1.3% VS 1.9%, P=0.203). THE MOST COMMON ENTRAPPED DEVICES DURING ANTEGRADE CTO PCI WERE ROTATIONAL ATHERECTOMY BURRS (N=6) AND BALLOONS (N=6), WHILE GUIDEWIRES (N=8) WERE THE MOST FREQUENT ENTRAPPED DEVICES DURING RETROGRADE CTO PCI. *DEVICE ENTRAPMENT MANAGEMENT TECHNIQUES OF DEVICE ENTRAPMENT ARE SUMMARIZED IN FIGURE 1 AND TABLE 3. PERCUTANEOUS RETRIEVAL OF THE ENTRAPPED DEVICES WAS ACHIEVED IN 35 OUT OF 36 CASES (97.2%): COMPLETE RETRIEVAL WAS ACHIEVED IN 23 (63.9%) CASES, WHILE PARTIAL RETRIEVAL OF THE ENTRAPPED MATERIAL WAS ACHIEVED IN 12 PATIENTS (33.3%). AMONG THE 13 ENTRAPPED GUIDEWIRES, ONE WAS COMPLETELY RETRIEVED USING THE TRAPPING BALLOON TECHNIQUE. IN THREE CASES, A CLEAN "CONTROLLED RUPTURE" WAS ACHIEVED, AND THE GUIDEWIRE'S TIPS WERE COMPLETELY COVERED AFTER STENT IMPLANTATION. IN EIGHT CASES, RETRIEVAL ATTEMPTS LED TO AN UNFOLDING OF THE TIP COIL INTO SMALL FILAMENTS AND A SNARE WAS REQUIRED TO REMOVE THE FOREIGN BODY; RESIDUAL UNRAVELLED FRAGMENTS WERE SUCCESSFULLY COVERED WITH A STENT IN SEVEN PATIENTS. HOWEVER, INCOMPLETE COVERAGE OF THE UNRAVELED SEGMENT OCCURRED IN ONE CASE DUE TO THE GUIDEWIRE UNRAVELLING INTO A SEPTAL BRANCH. FINALLY, ONE PATIENT REQUIRED EMERGENT SURGERY DUE TO FAILURE TO RETRIEVE A RETROGRADE RG3 WIRE (ASAHI INTECC, AICHI, JAPAN) THAT BECAME ENTRAPPED IN A BIOLOGICAL AORTIC VALVE PROSTHESIS. AMONG THE 6 CASES OF MICROCATHETER ENTRAPMENT, 5 TOOK PLACE DURING A RETROGRADE CTO PCI. IN 4 CASES THE ENTRAPMENT OCCURRED IN SMALL SHARPLY ANGULATED COLLATERAL BRANCHES. SUCCESSFUL RETRIEVAL WAS ACHIEVED BY CUTTING THE MICROCATHETER SHAFT AND ADVANCING A GUIDE CATHETER EXTENSION OVER THE SHAFT, FOLLOWED BY GENTLE PULLING OF THE ENTRAPPED MICROCATHETER. IN 1 CASE, A TIP FRACTURE OF THE MICROCATHETER (CORSAIR) OCCURRED WITHIN A VERY CALCIFIED CTO LESION DURING AN IPSILATERAL (SEPTAL-SEPTAL) RETROGRADE APPROACH. THE GUIDE- WIRE GOT STUCK WITHIN THE FRACTURED MICROCATHETER TIP, ALLOWING A SUCCESSFUL RETRIEVAL OF THE FRAGMENT BY PULLING THE RETROGRADE WIRE. THE ONLY CASE OF MICROCATHETER ENTRAPMENT THAT OCCURRED DURING AN ANTEGRADE APPROACH WAS CHARACTERISED BY MICROCATHETER TIP FRACTURE WITHIN THE CTO BODY. A BALLOON ANGIOPLASTY AROUND THE ENTRAPPED FRAGMENT MANAGED TO FREE THE TIP, ALLOWING ITS SUCCESSFUL RETRIEVAL WITH A SNARE. TABLE 3. DEVICE TECHNICAL FEATURES, CAUSES LEADING TO DEVICE ENTRAPMENT, RETRIEVAL TECHNIQUES AND CLINICAL OUTCOMES. GUIDEWIRES (N=13) *DEVICE SPECIFICATION FIELDER XT-A (N=1), ULTIMATEBROS 3 (N=1), GAIA SECOND (N=5), GAIA THIRD (N=3), CONQUEST PRO (N=2), RG3 (N=1) *ENTRAPMENT CAUSE EXCESSIVE TORQUE (N=7), AGGRESSIVE MANIPULATION (N=2), KNUCKLE WIRE (N=3), BIOLOGICAL AORTIC VALVE ENGAGEMENT (N=1) *RETRIEVAL TECHNIQUE TRAPPING BALLOON TECHNIQUE (N=1), CONTROLLED RUPTURE (N=3), SNARING (N=9) *FINAL RESULT COMPLETE RETRIEVAL (N=1), "CLEAN" FRAGMENT STENTING (N=3), UNRAVELLED FRAGMENT SNARING AND STENTING (N=8), FAILURE TO RETRIEVE (N=1) *MACCE MYOCARDIAL INFARCTION (N=1), URGENT SURGERY (N=1) MICROCATHETERS (N=6) *DEVICE SPECIFICATION CORSAIR (N=1), CORSAIR PRO (N=2), CARAVEL (N=3) *ENTRAPMENT CAUSE CALCIFIED LESION (N=2), THIN AND TORTUOUS COLLATERAL CHANNEL TRACKING (4) *RETRIEVAL TECHNIQUE SHAFT CUTTING AND TELESCOPING GCE (N=4), STRONG TRACTION (N=1), BALLOON ANGIOPLASTY AND SNARING (N=1) *FINAL RESULT COMPLETE RETRIEVAL (N=6) *MACCE MYOCARDIAL INFARCTION (N=2) FIELDER XT-A: MFR REPORT #: 3003775027-2025-00008 ULTIMATEBROS 3: MFR REPORT #: 3003775027-2025-00009 GAIA SECOND: MFR REPORT #: 3003775027-2025-00010 GAIA THIRD: MFR REPORT #: 3003775027-2025-00011 CONQUEST PRO: MFR REPORT #: 3003775027-2025-00012 CORSAIR: MFR REPORT #: 3003775027-2025-00013 CORSAIR PRO: MFR REPORT #: 3003775027-2025-00014 CARAVEL: MFR REPORT #: 3003775027-2025-00015.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1441334 | RG3 | PTCA GUIDE WIRE | DQX | ASAHI INTECC CO., LTD. | UNKNOWN | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | Required Intervention |