BLT Ø4.1MM RC, SLA® 8MM, TIZR, LOXIM
Report
- Report Number
- 0009613348-2025-001308
- Event Type
- Injury
- Date Received
- January 27, 2025
- Date of Event
- November 17, 2024
- Report Date
- January 27, 2025
- Manufacturer
- INSTITUT STRAUMANN AG
- Product Code
- DZE
- UDI-DI
- 07630031707123
- PMA / PMN Number
- K150938
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TH
- Reporter Occupation
- DENTIST
- Health Professional
- Yes
Narratives
`~1RP=TWQTHE BATCH NUMBER COULD BE VERIFIED. OUR MANUFACTURING Q-SYSTEM ASSURES, THAT PRODUCTION AND PROCESS CONTROLS ARE IN PLACE TO ENSURE THAT BATCHES CONFIRM TO THE APPLICABLE SPECIFICATIONS BEFORE THEY ARE DISTRIBUTED. THE LOSS OF AN ENDOSSEOUS DENTAL IMPLANT AFTER SUCCESSFUL OSSEOINTEGRATION AND RESTORATION IS A KNOWN INHERENT RISK OF THE PROCEDURE. IMPLANTS MAY HAVE TO BE REMOVED IN CASE ONE OR MORE OF THE IMPLANT SUCCESS CRITERIA ARE NOT MET. IMPLANT SUCCESS CRITERIA ACCORDING TO BUSER ET AL. (1991) ARE: 1. ABSENCE OF PERSISTENT SUBJECTIVE COMPLAINTS SUCH AS PAIN, FOREIGN BODY SENSATION AND /OR DYSESTHESIA 2. ABSENCE OF A RECURRENT PERI-IMPLANT INFECTION WITH SUPPURATION 3. ABSENCE OF IMPLANT MOBILITY 4. ABSENCE OF A CONTINUOUS RADIOLUCENCY AROUND THE IMPLANT. THE MANUFACTURER'S TREND ANALYSIS CONFIRMS THAT THE REPORTED FAILURE RATE ASSOCIATED WITH ITS DENTAL IMPLANTS IS BELOW THE EXPECTED FAILURE RATE FOR THIS TREATMENT AS PUBLISHED IN THE SCIENTIFIC LITERATURE. NON-FATAL SERIOUS INJURY OR DEVICE MALFUNCTION STORED DUE TO COVID 19 PANDEMIC IN ACCORDANCE WITH FDA GUIDANCE "POSTMARKETING ADVERSE EVENT REPORTING FOR MEDICAL PRODUCTS AND DIETARY SUPPLEMENTS DURING A PANDEMIC" PUBLISHED MAY 2020.
THE CLINICIAN REPORTS THE IMPLANT WAS INSERTED (B)(6) 2022 IN FDI 21. DETAILS OF SURGERY: RIDGE AUGMENTATION. ON (B)(6) 2024, LOSS OF OSSEOINTEGRATION WAS VERIFIED. PATIENT PRESENTED WITH BONE TYPE III. THE DEVICE WAS FORWARDED TO THE MANUFACTURER. AT THE EVENT THE PATIENT EXPERIENCED: PAIN AND MOBILITY. NO FURTHER PATIENT COMPLICATIONS WERE REPORTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 771057 | BLT Ø4.1MM RC, SLA® 8MM, TIZR, LOXIM | ENDOSSEOUS DENTAL IMPLANT | DZE | INSTITUT STRAUMANN AG | MPW64 | 07630031707123 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 34 YR | Male | Required Intervention |