FDA Adverse Event Injury Summary report: N

AXIOS STENT AND ELECTROCAUTERY ENHANCED DELIVERY SYSTEM

MDR report key: 21154190 · Received January 14, 2025

Report

Report Number
3005099803-2024-06920
Event Type
Injury
Date Received
January 14, 2025
Date of Event
December 29, 2022
Report Date
January 14, 2025
Manufacturer
BOSTON SCIENTIFIC CORPORATION
Product Code
PCU
PMA / PMN Number
K220112
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
TW
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INITIAL REPORTER ADDRESS NO. 21, SECTION 2, NANYA S. ROAD; REPORTED HERE AS THE ADDRESS EXCEEDED CHARACTER LIMIT FOR THE DESIGNATED FIELD. LITERATURE SOURCE: CHEN-SHUAN CHUNG ET AL. RESCUING MALDEPLOYMENT OF LUMEN-APPOSING METAL STENT FOR THE MANAGEMENT OF ACUTE CHOLECYSTITIS. DIGESTIVE ENDOSCOPY (2023) 35:670. DOI: 10.1111/DEN.14572. IMDRF DEVICE CODE A1502 CAPTURES THE REPORTABLE EVENT OF STENT FIRST FLANGE DIFFICULT TO POSITION.

Description of Event or Problem · 0

BOSTON SCIENTIFIC CORPORATION BECAME AWARE OF THE FOLLOWING EVENT FROM REFERENCED LITERATURE ARTICLE "RESCUING MALDEVELOPMENT OF LUMEN-APPOSING METAL STENT FOR THE MANAGEMENT OF ACUTE CHOLECYSTITIS." ACCORDING TO THE LITERATURE, AN AXIOS STENT AND ELECTROCAUTERY ENHANCED DELIVERY SYSTEM WAS IMPLANTED TRANSDUODENAL TO GALLBLADDER FOR THE TREATMENT OF ACUTE CHOLECYSTITIS DURING AN ENDOSCOPIC ULTRASOUND-GUIDED GALLBLADDER DRAINAGE PROCEDURE PERFORMED ON (B)(6) 2022. DURING THE PROCEDURE, THE STENT WAS DEPLOYED; HOWEVER, NO DRAINAGE OF BILE WAS OBSERVED. IT WAS CONFIRMED UNDER FLUOROSCOPY THAT THE DISTAL FLANGE WAS DEPLOYED BETWEEN THE DUODENUM AND GALLBLADDER. A GUIDEWIRE WAS THEN ADVANCED THROUGH THE LUMEN-APPOSING METAL STENT AND THREE 10F-3CM AND TWO 7F-3CM DOUBLE PIGTAIL PLASTIC STENTS WERE SUCCESSFULLY IMPLANTED. NO PATIENT COMPLICATIONS WERE REPORTED DUE TO THIS EVENT AND THE PATIENT LIVED UNEVENTFULLY FOR 6 MONTHS. NOTE: IT WAS REPORTED THAT THE AXIOS STENT WAS PLACED TRANSDUODENAL TO GALLBLADDER. HOWEVER, PER THE AXIOS STENT AND ELECTROCAUTERY- ENHANCED DELIVERY SYSTEM DIRECTIONS FOR USE, THE STENT IS INDICATED FOR USE TO FACILITATE TRANSGASTRIC OR TRANSDUODENAL ENDOSCOPIC DRAINAGE OF A PANCREATIC PSEUDOCYST OR A WALLED-OFF NECROSIS WITH >= 70 % FLUID CONTENT. THE DEVICE IS NOT INDICATED TO BE IMPLANTED IN THE GALLBLADDER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1516734 AXIOS STENT AND ELECTROCAUTERY ENHANCED DELIVERY SYSTEM PANCREATIC STENT, COVERED, METALLIC, REMOVABLE PCU BOSTON SCIENTIFIC CORPORATION M00553570 0027516261

Patients

Seq Age Sex Outcome Treatment
1 85 YR Female Required Intervention