FDA Adverse Event Malfunction Summary report: N

MULTI-LINK MINI VISION RX CORONARY STENT SYSTEM

MDR report key: 2111719 · Received June 2, 2011

Report

Report Number
2024168-2011-03843
Event Type
Malfunction
Date Received
June 2, 2011
Date of Event
May 8, 2011
Report Date
May 9, 2011
Manufacturer
AV-TEMECULA-CT
Product Code
MAF
PMA / PMN Number
P020047
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
HEALTH PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

(B)(4). DURING PROCESSING OF THIS COMPLAINT, ATTEMPTS WERE MADE TO OBTAIN COMPLETE EVENT, PATIENT AND DEVICE INFORMATION. THE MINI VISION 2.25 X 08 MM IS BEING FILED UNDER A SEPARATE MANUFACTURER REPORT NUMBER. BALLOON MATERIAL RUPTURES CAN BE AFFECTED BY NUMEROUS FACTORS INCLUDING, BUT NOT LIMITED TO, BALLOON DAMAGE DURING MANUFACTURING, MATERIALS, HANDLING, LESION CALCIFICATION AND TORTUOSITY, AN INTERACTION WITH A PREVIOUSLY IMPLANTED STENT, INSUFFICIENT PREPARATION PRIOR TO USE OR FROM INTERACTIONS WITH OTHER DEVICES. TO ENSURE THIS IS NOT A RESULT OF MANUFACTURING, ALL BALLOON CATHETERS ARE 100% VISUALLY INSPECTED AND LEAK TESTED PRIOR TO PACKAGING. ADDITIONALLY, A SAMPLING OF UNITS IS DESTRUCTIVELY TESTED TO VERIFY RATED BURST PRESSURE (RBP). RETURN OF THE MINI VISION STENT DELIVERY SYSTEM (SDS) USED IN THE PROCEDURE MAY HAVE AIDED IN THE INVESTIGATION AND DETERMINATION OF CAUSE. THERE WAS NO REPORT OF ANY LEAK IN THE CATHETER NOTED DURING PREPARATION FOR USE, WHICH WOULD SUGGEST THAT THE BALLOON WAS NOT DAMAGED PRIOR TO USE. IT IS POSSIBLE THAT THE BALLOON MATERIAL WAS DAMAGED (SCRATCHED) DURING INTERACTIONS WITH ACCESSORY DEVICES, OR THE LESION/ANATOMY, SUCH THAT THE BALLOON RUPTURED UPON INFLATION AT 10ATM WHICH IS BELOW THE RBP. A REVIEW OF THE PRODUCT MANUFACTURING RECORDS DID NOT REVEAL ANY NON-CONFORMING MATERIAL RECORDS ASSOCIATED WITH THIS LOT AND ALL LOT RELEASE TESTING MET MANUFACTURING CRITERIA. ADDITIONALLY, A REVIEW OF THE COMPLAINT-HANDLING DATABASE WAS PERFORMED AND THERE IS NO INDICATION OF A LOT SPECIFIC PRODUCT QUALITY DEFICIENCY. IN THIS CASE, WITHOUT THE PRODUCT TO EXAMINE, A DEFINITIVE CAUSE FOR THE REPORTED BALLOON RUPTURE CANNOT BE DETERMINED.

Description of Event or Problem · 1

IT WAS REPORTED THAT DURING USE OF THE TWO MINI VISIONS IN THE PATIENT ANATOMY, BOTH BALLOONS RUPTURED AT 10 ATMOSPHERES (ATM). NO ADVERSE PATIENT EFFECTS WERE REPORTED. NO ADDITIONAL EVENT OR PATIENT INFORMATION WAS PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 MULTI-LINK MINI VISION RX CORONARY STENT SYSTEM CORONARY STENT SYSTEM MAF AV-TEMECULA-CT 0101441

Patients

Seq Age Sex Outcome Treatment
1