CARPENTIER-EDWARDS PERIMOUNT RSR PERICARDIAL BIOPROSTHESIS
Report
- Report Number
- 2015691-2011-15612
- Event Type
- Injury
- Date Received
- May 25, 2011
- Date of Event
- February 4, 2011
- Report Date
- April 27, 2011
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- DYE
- PMA / PMN Number
- P860057/S001
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- UT, US
- Reporter Occupation
- OTHER
Narratives
(B)(4) DEVICE NOT RETURNED. ADDITIONAL MANUFACTURER NARRATIVE: THE DEVICE HISTORY RECORD REVIEW WAS COMPLETED AND CONFIRMS THAT THIS DEVICE PASSED ALL MANUFACTURING AND STERILIZATION INSPECTIONS. THE SUBJECT DEVICE HAS NOT BEEN RETURNED FOR EVALUATION, THEREFORE, THE REPORTED CALCIFICATION AND STENOSIS CANNOT BE POSITIVELY CONFIRMED. CALCIFICATION IS A WELL RECOGNIZED FAILURE MODE OF BIOPROSTHETIC VALVES. THE MECHANISMS FOR BIOPROSTHETIC HEART VALVE TISSUE CALCIFICATION ARE NOT FULLY UNDERSTOOD. MANY FACTORS CAN CONTRIBUTE TO THE ONSET AND PROPAGATION OF CALCIFICATION INCLUDING PATIENT RELATED (E.G. PATIENT AGE, DISEASE STATE, IMMUNE STATUS, AND OTHER CO-MORBIDITIES), PHARMACOLOGICAL, AND INTRINSIC PROPERTIES OF THE VALVE ITSELF. IT IS WIDELY UNDERSTOOD THAT PATIENTS WITH CHRONIC RENAL DISEASE AND PRIOR HISTORY OF CALCIFIC STENOSIS OF THE NATIVE VALVE MAY BE PREDISPOSED TO BIOPROSTHETIC CALCIFICATION. THERE INVESTIGATION REVEALS NOTHING TO INDICATE A DEVICE QUALITY DEFICIENCY THAT MAY HAVE CONTRIBUTED TO THIS EVENT.
EDWARDS LIFESCIENCES MAINTAINS AN IMPLANT PATIENT REGISTRY. THIS REGISTRY IS A PATIENT TRACKING MECHANISM FOR SERIALIZED EDWARDS IMPLANTABLE DEVICES (BIOPROSTHETIC HEART VALVES AND ANNULOPLASTY RINGS), RATHER THAN A TRUE POST-MARKET SURVEILLANCE REGISTRY. THROUGH THE REGISTRY, EDWARDS IS NOTIFIED WHEN THESE DEVICES ARE IMPLANTED. IN ADDITION, PATIENT AND/OR DEVICE STATUS MAY BE REPORTED TO THE REGISTRY VIA THE IMPLANTATION DATA CARDS. THE INFORMATION IS RECEIVED FROM VARIOUS SOURCES (E.G. SURGEON, HOSPITAL, AND PATIENT FAMILY MEMBERS) AND IS NOT RECEIVED IN THE FORM OF A CONVENTIONAL "CUSTOMER COMPLAINT". THE INFORMATION REPORTED MAY OR MAY NOT BE RELATED TO THE EDWARDS DEVICE. IN THIS CASE, IT WAS LEARNED THAT THE EDWARDS' AORTIC BIOPROSTHESIS WAS EXPLANTED AFTER AN IMPLANT DURATION OF APPROXIMATELY 103 MONTHS, DUE TO STENOSIS AND CALCIFICATION; ANOTHER EDWARDS' BIOPROSTHESIS WAS IMPLANTED IN PLACE. OPERATIVE REPORT INDICATES, " WE EXPLANTED THE VALVE BY TAKING INDIVIDUAL SUTURES OUT AND REMOVING IT CAREFULLY, DEBRIDING VERY GINGERLY" PATHOLOGY REPORT INDICATES, " [SUBJECT] AORTIC VALVE WAS RECEIVED IN FORMALIN IN A CONTAINER LABELED WITH THIS PATIENT'S ID STAMP. IT CONTAINS A TRILEAFLET TYPE PROSTHETIC AORTIC VALVE. THE OUTER DIAMETER IS 3.2 X 3.0 CM. THE LEAFLETS SHOW MODERATE CALCIFICATION AND STIFFENING, RESULTING IN A GAP AT THE CENTRAL JUNCTION."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | CARPENTIER-EDWARDS PERIMOUNT RSR PERICARDIAL BIOPROSTHESIS | REPLACEMENT HEART VALVE | DYE | EDWARDS LIFESCIENCES | 2800 | 1M1791 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 83 YR | Hospitalization| R |