DAVINCI XI
Report
- Report Number
- 2955842-2024-23385
- Event Type
- Malfunction
- Date Received
- December 19, 2024
- Date of Event
- November 25, 2024
- Report Date
- November 25, 2024
- Manufacturer
- INTUITIVE SURGICAL, INC
- Product Code
- NAY
- PMA / PMN Number
- K131861
- Removal / Correction Number
- N/A
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SP
- Reporter Occupation
- NURSE
- Health Professional
- Yes
Narratives
INTUITIVE SURGICAL, INC. (ISI) DID RECEIVE A DA VINCI PRODUCT INVOLVED WITH THIS COMPLAINT TO PERFORM FAILURE ANALYSIS. THE INTEGRATED ELECTROSURGICAL UNIT (IESU) OR ERBE WAS RETURNED FOR FAILURE ANALYSIS, AND THE REPORTED (MONOPOLAR NOT FIRING) ERROR WAS CONFIRMED BUT NOT REPLICATED. IN ERROR LOGS, THE (M-36) ERROR WAS FOUND, CONFIRMING THE FAULT OCCURRED IN THE FIELD. UP VISUAL INSPECTION, NO ISSUES WERE FOUND THAT WOULD BE RELATED TO THE REPORTED EVENT. THE UNIT WAS INSTALLED ON AN IN-HOUSE SYSTEM WHERE THE UNIT FUNCTIONED AS EXPECTED. THE UNIT ENERGIZED AND CAUTERIZED AND ALL PORTS RECOGNIZED INSTRUMENTS. AS A SAFETY PRECAUTION THE UNIT WILL BE RETURNED TO ORIGINAL EQUIPMENT MANUFACTURER (OEM) TO DETERMINE THE ROOT CAUSE AND FOR FURTHER INVESTIGATION. THE COMPLAINT WAS NOT CONFIRMED BASED ON FAILURE ANALYSIS. THE PROBABLE ROOT CAUSE IS ATTRIBUTED TO AN ELECTRICAL COMPONENT FAILURE.
AN INVESTIGATION WAS COMPLETED TO DETERMINE THE CAUSE OF THIS REPORTED EVENT. AN INTUITIVE SURGICAL, INC. (ISI) FIELD SERVICE ENGINEER (FSE) WAS DISPATCHED TO THE CUSTOMER SITE TO FURTHER INVESTIGATE THE REPORTED EVENT. FSE REPLACED THE INTEGRATED ELECTROSURGICAL UNIT (IESU) OR ERBE. SYSTEM VERIFIED AND READY FOR USE. THE COMPLAINT WAS CONFIRMED BASED ON FIELD EVALUATION.
REFER TO H11 FOR FOLLOW-UP INFORMATION.
IT WAS REPORTED THAT DURING A DA VINCI-ASSISTED PROSTATECTOMY-SIMPLE SURGICAL PROCEDURE, CUSTOMER CONTACTED INTUITIVE SURGICAL, INC. (ISI) TECHNICAL SERVICE ENGINEER (TSE) AND REPORTED MONOPOLAR ENERGY WAS NOT FIRING. PRIOR TO CONTACTING TSE, CUSTOMER TRIED TWO DIFFERENT CAUTERY CABLES AND MONOPOLAR INSTRUMENTS WITHOUT SUCCESS. CUSTOMER STATED THEY HAD A QUESTION MARK ON INTEGRATED ELECTROSURGICAL UNIT (IESU) OR ERBE'S PORT WHERE MONOPOLAR INSTRUMENT WAS CONNECTED. TSE REVIEWED ERROR LOGS AND FOUND ERROR "M36". TSE ASKED CUSTOMER TO CONNECT CAUTERY CABLE TO THE OTHER MONOPOLAR PORT WITHOUT SUCCESS. TSE ASKED CUSTOMER TO REMOVE ALL ENERGIZED INSTRUMENTS FROM PATIENT SIDE CART (PSC) AND CAUTERY CABLES FROM ERBE WITHOUT SUCCESS. TSE ASKED CUSTOMER TO INSTALL MONOPOLAR INSTRUMENT ON UNIVERSAL SURGICAL MANIPULATOR (USM1) INSTEAD OF USM4 WITHOUT SUCCESS. TSE ASKED CUSTOMER TO TRY A THIRD CAUTERY CABLE WITHOUT SUCCESS. TSE ASKED CUSTOMER TO TRY A THIRD MONOPOLAR INSTRUMENT WITHOUT SUCCESS. TSE ASKED CUSTOMER TO VERIFY ERBE CONNECTION WITH VIDEO PROCESSOR AND SHE STATED IT WAS PROPERLY CONNECTED. TSE ASKED CUSTOMER WHETHER THEY HAD A FORCE TRIAD, AND THEY HAD IT. THEY WERE NOT ABLE TO FIND ACTIVATION CABLE. SURGEON TRIED MONOPOLAR ENERGY WITH FORCE TRIAD AND ITS EXTERNAL PEDALS AND CUSTOMER STATED IT WAS NOT DELIVERING ENOUGH ENERGY. THEY DECIDED TO CONTINUE THE PROCEDURE USING SYNCHROSEAL INSTRUMENT INSTEAD OF MONOPOLAR CURVED SCISSORS (MCS). THE PROCEDURE WAS COMPLETING AS PLANNED WITH NO REPORTED INJURY. INTUITIVE SURGICAL, INC. (ISI) FOLLOWED UP WITH THE INITIAL REPORTER AND OBTAINED THE FOLLOWING ADDITIONAL INFORMATION: THE PROCEDURE COMPLETED ROBOTICALLY USING SYNCHROSEAL (E100) AND BIPOLAR ENERGY (ERBE). THE TYPE OF DA VINCI-ASSISTED SURGICAL PROCEDURE WAS PERFORMED BY THE SURGEON WAS PROSTATECTOMY. THE PROCEDURE BEGAN AT 3:20 PM ON (B)(6) 2024. MONOPOLAR ENERGY WAS NOT AVAILABLE FOR THE ENTIRETY OF THE PROCEDURE; THEY USED SYNCHROSEAL INSTEAD OF MONOPOLAR ENERGY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2284099 | DAVINCI XI | VISION SIDE SYSTEM | NAY | INTUITIVE SURGICAL, INC | 381121-39 | N/A |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | DA VINCI INSTRUMENTS AND ACCESSORIES |