SNAPLOC WIRE GUIDE LOCKING DEVICE
Report
- Report Number
- 1037905-2024-00806
- Event Type
- Malfunction
- Date Received
- December 13, 2024
- Date of Event
- November 18, 2024
- Report Date
- December 13, 2024
- Manufacturer
- WILSON-COOK MEDICAL INC
- Product Code
- ODC
- UDI-DI
- 00827002596832
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- NURSE
- Health Professional
- Yes
Narratives
PMA/510(K) # K213483. INVESTIGATION EVALUATION: A PRODUCT EVALUATION WAS NOT PERFORMED IN RESPONSE TO THIS REPORT BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT PROVIDED TO COOK FOR EVALUATION. THE REPORT COULD NOT BE CONFIRMED. THE DEVICE HISTORY RECORD FOR THE LOT NUMBER SAID TO BE INVOLVED WAS REVIEWED. A DISCREPANCY OR ANOMALY WAS NOT OBSERVED WITH THE PRODUCT THAT WAS RELEASED FOR DISTRIBUTION. INVESTIGATION CONCLUSION: WE COULD NOT CONDUCT A COMPLETE INVESTIGATION BECAUSE THE PRODUCT SAID TO BE INVOLVED WAS NOT RETURNED FOR EVALUATION. A DEFINITIVE CAUSE FOR THE REPORTED OBSERVATION COULD NOT BE DETERMINED. PRIOR TO DISTRIBUTION, ALL SNAPLOC WIRE GUIDE LOCKING DEVICES ARE SUBJECTED TO A VISUAL INSPECTION AND FUNCTIONAL TESTING TO ENSURE DEVICE INTEGRITY. A REVIEW OF THE DEVICE HISTORY RECORD CONFIRMED THAT THE LOT SAID TO BE INVOLVED MET ALL MANUFACTURING REQUIREMENTS PRIOR TO SHIPMENT. CORRECTIVE ACTION: BASED ON THE QUALITY ENGINEERING RISK ASSESSMENT NO CORRECTIVE ACTION IS WARRANTED AT THIS TIME. A REVIEW OF THE COMPLAINT HISTORY WAS CONDUCTED. QUALITY ASSURANCE WILL CONTINUE TO MONITOR FOR COMPLAINT TRENDS.
DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE, THE PHYSICIAN USED A COOK SNAPLOC WIRE GUIDE LOCKING DEVICE. IT WAS REPORTED THAT THE WIRE GUIDE WIRE SLIPPED ON NUMEROUS OCCASIONS WHILST IT WAS LOCKED OFF IN THE WIRE LOCK DEVICE. THE PHYSICIAN DIDN'T LOSE ACCESS IN THE CBD [COMMON BILE DUCT] BUT HAD TO WATCH CAREFULLY. THE WIRE SLIPPED WHILST ON ITS OWN WHILST LOCKED AND WAITING FOR THE NURSE TO PREPARE THE NEXT DEVICE. THE WIRE GUIDE ALSO SLIPPED WHILST INSIDE THE SPHINCTEROTOME AND LOCKED USING THE WIRE LOCK. A SECTION OF THE DEVICE DID NOT REMAIN INSIDE THE PATIENT¿S BODY. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES DUE TO THIS OCCURRENCE. ACCORDING TO THE INITIAL REPORTER, THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 2417725 | SNAPLOC WIRE GUIDE LOCKING DEVICE | ODC ENDOSCOPE CHANNEL ACCESSORY | ODC | WILSON-COOK MEDICAL INC | G59683 | W4859634 | 00827002596832 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NA | Unknown | 0.35MM VISIGLIDE 2 WIRE.| CLEVERCUT 3V PRELOADED| OLYMPUS DUODENOSCOPE TJF-Q190V |