FDA Adverse Event Injury Summary report: N

UNK_PHACO TIP/NEEDLE

MDR report key: 20828227 · Received December 2, 2024

Report

Report Number
3012236936-2024-000323
Event Type
Injury
Date Received
December 2, 2024
Date of Event
November 4, 2024
Report Date
January 3, 2025
Manufacturer
JOHNSON & JOHNSON SURGICAL VISION, INC.
Product Code
HQC
PMA / PMN Number
K121721
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
MN, US
Reporter Occupation
PHYSICIAN
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL INFORMATION: SECTION A4: 145 POUNDS. SECTION A5: NATIVE HAWAIIAN OR OTHER PACIFIC ISLANDER ASIAN, NOT HISPANIC/NOT LATINO. SECTION B3 DATE OF EVENT: NOV 4, 2024. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC HAS BEEN SUBMITTED.

Additional Manufacturer Narrative · 0

D10 - CONCOMITANT - WHITESTAR SN (B)(6), ELLIPS FX HANDPIECE MODEL 690880. SECTION H4. DEVICE MANUFACTURE DATE: UNKNOWN, AS THE LOT NUMBER OF THE DEVICE WAS NOT PROVIDED. SECTION H3: THE DEVICE WAS NOT RETURNED FOR EVALUATION. THEREFORE, A FAILURE ANALYSIS OF THE COMPLAINT DEVICE CANNOT BE COMPLETED. A REVIEW OF THE DEVICE HISTORY RECORD, COMPLAINT TRENDING, AND RISK DOCUMENTATION FOR THIS DEVICE WILL BE PERFORMED. UPON COMPLETION OF THE REVIEW, IF THERE IS ANY FURTHER RELEVANT INFORMATION A SUPPLEMENTAL MEDWATCH WILL BE FILED. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON AND JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE SYSTEM PRIMED AND TUNED CORRECTLY PRIOR TO THE CASE BUT DURING PHACO, THE MACHINE WAS GIVING THE OCCLUSION SOUND (DINGING) ALTHOUGH THE MACHINE WAS NOT OCCLUDED. AT THAT POINT, THE DOCTOR APPLIED MORE PHACO POWER THAN NEEDED. HE THOUGHT THERE MUST HAVE BEEN SOME LENS MATERIAL OCCLUDING THE TIP (THAT WAS THE SIGNAL FOR HIM TO DEPRESS THE FOOT PEDAL TO APPLY POWER). AS A RESULT OF THIS, A WOUND BURN OCCURRED ON THE PATIENT'S RIGHT EYE. DOCTOR TRIED FLUSHING THE HANDPIECE WITH SALINE, ASSUMING IT WAS OCCLUDED SOMEWHERE, BUT IT FLUSHED NORMALLY. AFTER THIS, THE DOCTOR TRIED USING THE HANDPIECE AGAIN AND HAD THE SAME ISSUE. THEY RERAN THE PRIME AND TUNE WHICH GAVE AN ERROR FOR "LOOSE HANDPIECE." THEY THEN GOT ANOTHER HANDPIECE WHICH PRIMED AND TUNED CORRECTLY AND FINISHED THE PHACO PORTION OF THE PROCEDURE NORMALLY. DOCTOR COULD NOT GET THE MAIN INCISION TO SEAL WITH AGGRESSIVE HYDRATION (DUE TO THE WOUND BURN), SO ULTIMATELY PLACED A SUTURE. THE PATIENT HAS DONE VERY WELL. NO ADDITIONAL INFORMATION HAS BEEN PROVIDED. THIS REPORT IS AGAINST THE TIP. A SEPARATE REPORT WILL BE FILED AGAINST THE HANDPIECE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
2290083 UNK_PHACO TIP/NEEDLE PHACO TIP HQC JOHNSON & JOHNSON SURGICAL VISION, INC. UNKNOWN UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 69 YR Female Required Intervention