FDA Adverse Event Malfunction Summary report: N

ONETOUCHPING GLUCOSEMGMTSYSTEM

MDR report key: 2082198 · Received May 9, 2011

Report

Report Number
2531779-2011-03237
Event Type
Malfunction
Date Received
May 9, 2011
Date of Event
April 12, 2011
Report Date
April 12, 2011
Manufacturer
ANIMAS CORPORATION
Product Code
LZG
PMA / PMN Number
K080639
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NC, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THE PUMP HAS NOT BEEN RETURNED TO ANIMAS FOR EVALUATION. IF THE DEVICE IS RETURNED, AN EVALUATION SHALL BE COMPLETED AND A SUPPLEMENTAL REPORT WILL BE FILLED. NO CONCLUSIONS CAN BE DRAWN AT THIS TIME.

Additional Manufacturer Narrative · 1

(B)(4). DEVICE EVALUATION: THE PUMP HAS BEEN RETURNED AND EVALUATED BY PRODUCT ANALYSIS ON (B)(4) 2011 WITH THE FOLLOWING FINDINGS: EVALUATION REVEALED THAT THE PUMP POWERS ON NORMALLY WITH NO ALARMS. DURING INVESTIGATION, THE BATTERY CAP ATTACHED SECURELY TO THE PUMP. THERE WAS NO DAMAGE NOTED TO THE BATTERY CAP OR THE BATTERY COMPARTMENT; NO DEFECTS WERE FOUND TO THE BATTERY CONNECTIONS OR TO THE POWER CIRCUIT. A REVIEW OF THE PUMP HISTORY INDICATED THAT REBOOTING HAD OCCURRED WHICH COULD NOT BE DUPLICATED DURING TESTING. THERE WERE NO ALARMS RELATED TO THE COMPLAINT NOTED IN THE ALARM HISTORY. THE PUMP WAS FOUND TO BE OPERATING WITHIN REQUIRED SPECIFICATIONS AND DELIVERING INSULIN ACCURATELY. A REVIEW OF THE PUMP HISTORY INDICATED THAT INSULIN DELIVERY TOTALS CORRECTLY REFLECTED PROGRAMMED VALUES. THE PUMP WAS EXERCISED FOR 29 HOURS WITH NO INSULIN DELIVERY ISSUES.

Description of Event or Problem · 1

THE REPORTER ALLEGED THAT THE ANIMAS INSULIN PUMP HAS A SELF-REBOOT ISSUE. REPORTEDLY, THE PUMP IS REPEATEDLY SHOWING THE VERIFICATION SCREEN. AT THE TIME OF CONCERN, THE PATIENT'S BLOOD GLUCOSE WAS "363 MG/DL" WITH NO SYMPTOMS. THERE WAS NO REPORT OF MEDICAL INTERVENTION THAT WOULD SUGGEST A SERIOUS INJURY. DURING TROUBLESHOOTING, THE REPORTER NOTED THE FOLLOWING: SPRING/METAL CONTACTS AND THREADS ARE INTACT. THREADS IN BATTERY COMPARTMENT ARE INTACT. NO CRACKS FOUND NEAR BATT COMPARTMENT. CHIP IN PAINT LOCATED ON SEAM ON BOTTOM OF PUMP. BATTERY COMPARTMENT HAS NO EVIDENCE OF MOISTURE/CORROSION. THIS COMPLAINT IS BEING REPORTEDLY AS A MALFUNCTION DUE TO THE ALLEGED SELF-REBOOT ISSUE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 ONETOUCHPING GLUCOSEMGMTSYSTEM INSULIN INFUSION PUMP LZG ANIMAS CORPORATION ANM IR1200/1250/2020/OTP CART

Patients

Seq Age Sex Outcome Treatment
1 10 YR