PINNACLE MTL INS NEUT36IDX58OD
Report
- Report Number
- 1818910-2011-06493
- Event Type
- Injury
- Date Received
- April 15, 2011
- Date of Event
- March 18, 2011
- Report Date
- October 18, 2012
- Manufacturer
- DEPUY ORTHOPAEDICS INC US
- Product Code
- KWA
- PMA / PMN Number
- K003523
- Removal / Correction Number
- NA
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AL, US
- Reporter Occupation
- OTHER
Narratives
THIS COMPLAINT IS STILL UNDER INVESTIGATION. DEPUY WILL NOTIFY THE FDA OF THE RESULTS OF THIS INVESTIGATION ONCE IT HAS BEEN COMPLETED.
THIS COMPLAINT IS STILL UNDER INVESTIGATION. DEPUY WILL NOTIFY THE FDA OF THE RESULTS OF THIS INVESTIGATION ONCE IT HAS BEEN COMPLETED.
NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. BASED ON PREVIOUS INVESTIGATIONS THIS COMPLICATION OF JOINT REPLACEMENT IS UNLIKELY TO HAVE BEEN THE RESULT OF A DEVICE FAILING TO MEET REQUIRED SPECIFICATIONS. THE INFORMATION RECEIVED WILL BE RETAINED FOR POTENTIAL SERIES INVESTIGATIONS IF TRIGGERED BY TREND ANALYSIS, POST MARKET SURVEILLANCE, OR OTHER EVENTS WITHIN THE QUALITY SYSTEM. CORRECTIVE ACTION WAS NOT INDICATED. DEPUY CONSIDERS THE INVESTIGATION CLOSED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED AND THE INVESTIGATION WILL BE RE-OPENED AS NECESSARY.
(B)(4).
PRODUCT COMPLAINT # (B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. INVESTIGATION SUMMARY: NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. THE INFORMATION RECEIVED WILL BE RETAINED FOR POTENTIAL SERIES INVESTIGATIONS IF TRIGGERED BY TREND ANALYSIS, POST MARKET SURVEILLANCE, OR OTHER EVENTS WITHIN THE QUALITY SYSTEM. DEPUY CONSIDERS THE INVESTIGATION CLOSED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED AND THE INVESTIGATION WILL BE RE-OPENED AS NECESSARY. NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. THE ADVERSE SYMPTOMS ALLEGED AND PRODUCT CODE REPORTED IS ASSOCIATED WITH THE DEPUY METAL ON METAL ARTICULATION. A COMPLAINT DATABASE SEARCH AND/OR DEVICE MANUFACTURING (DHR) REVIEWS WILL NOT BE PERFORMED. PER WI-3430 IT HAS BEEN DETERMINED THAT SHOULD RELATED REPORTS BE IDENTIFIED A DHR REVIEW IS NOT REQUIRED. INVESTIGATIONAL INPUTS WERE REQUESTED AS INDICATED PER INTERNAL PROCEDURES FOR THIS FAILURE MODE. THE COMPLAINT INFORMATION PROVIDED HAS BEEN REVIEWED FOR COMPLAINT CODING, MEDICAL DEVICE REPORTING, AND OTHER DATA REQUIRED BY THE COMPLAINT SYSTEM. PER INTERNAL PROCEDURES, THE EVENT INFORMATION AND ANY INVESTIGATIONAL INPUTS RECEIVED AS PART OF REQUIRED FOLLOW UP WERE REVIEWED. FOR THIS INVESTIGATION, NO IMMEDIATE ACTION WAS REQUIRED AS NO ALLEGED DEFICIENCY WITH THE DEVICE(S) WAS IDENTIFIED. WITHOUT THE PHYSICAL COMPLAINT SAMPLE(S) ASSOCIATED WITH THIS REPORT, IT WAS NOT POSSIBLE TO DETERMINE IF THE DEVICE(S) FAILED TO MEET SPECIFICATION(S) AT THE TIME IT WAS RELEASED FOR DISTRIBUTION. THE DEVICE(S) ASSOCIATED WITH THIS EVENT WERE USED IN THE TREATMENT OF THE PATIENT AS PRESCRIBED BY THE PRESIDING SURGEON. FROM THE EVENT INFORMATION RECEIVED, IT WAS NOT POSSIBLE TO DETERMINE THE RELATIONSHIP OF THE DEVICE TO THE REPORTED EVENT. NO INFORMATION RECEIVED WITH THIS INDIVIDUAL COMPLAINT INDICATED THAT A BROADER INVESTIGATION OR CORRECTIVE ACTION WAS NECESSARY. DEPUY SYNTHES CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED AND THE INVESTIGATION MAY BE RE-OPENED AS NECESSARY.
UPDATE: (B)(4) 2012 PFS WAS RECEIVED FROM LEGAL, MEDICAL RECORDS WERE RECEIVED FROM LEGAL, AND PART/LOT INFORMATION WAS IDENTIFIED. RECORDS ARE AVAILABLE FOR FURTHER REVIEW.
IN ADDITION TO WHAT WERE PREVIOUSLY ALLEGED, PPF ALLEGES INFECTION AND BLOOD HEAVY METAL INCREASE.
PT REVISED FOR PAIN, METALLOSIS AND METAL DEBRIS. INFARCT OCCURRED AS A RESULT OF METAL DEBRIS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | PINNACLE MTL INS NEUT36IDX58OD | 87 KWA | KWA | DEPUY ORTHOPAEDICS INC US | NA | 1098340 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 50 YR | Required Intervention |